Ernie Che Mid
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ernie Che Mid has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Samila Mat Zali
Universiti Malaysia Perlis
2 shared publications - Baharuddin Ismail
Centre of Excellence for Renewable Energy, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia
1 shared publication D A Hadi
Faculty of Electrical and Electronic Engineering Technology, Technology Campus, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100 Durian Tunggal, Melaka, Malaysia
1 shared publication- E Ruslan
Faculty of Electrical and Electronic Engineering Technology, Technology Campus, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100 Durian Tunggal, Melaka, Malaysia
1 shared publication - Hairul Nizam Talib
Universiti Teknikal Malaysia Melaka
1 shared publication - Mohammad Haziq Ismail
Universiti Malaysia Perlis
1 shared publication
Latest Publications
- 11 September 2025
- Published by Elsevier in Next Research
- Vol. 2 (4)
Hyperparameter optimization using automated machine learning based artificial neural network for fault detection in wind turbine generator
- 11 September 2025
- Published by Elsevier in Next Research
- Vol. 2 (4)
Hyperparameter optimization using automated machine learning based artificial neural network for fault detection in wind turbine generator
- Open Access
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 13 (4) , 808-814
Power losses analysis for reduced switch 9-level cascaded H-bridge multilevel inverter
This study provides a thorough examination of power losses and total harmonic distortion (THD) in single-phase 9-level cascaded H-bridge multilevel inverters (CHB MLI) at low switching frequencies. The aim is to analyze the efficiency of a single-phase 9-level cascaded CHB MLI using three distinct switch configurations: 16-switch, 11-switch, and proposed 8-switch. The calculated switching angles are optimized using the feed-forward methodology. Two types of load conditions—R load and R-L load—are being examined. The results suggest that the proposed 8-switch design exhibits superior efficiency by limiting power losses compared to other topologies. Regarding THD, the conventional topology yields a somewhat lower value, however, the disparity is less than 1% when compared to both reduced switch topologies.
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 13 (4) , 808-814
Open AccessPower losses analysis for reduced switch 9-level cascaded H-bridge multilevel inverter
This study provides a thorough examination of power losses and total harmonic distortion (THD) in single-phase 9-level cascaded H-bridge multilevel inverters (CHB MLI) at low switching frequencies. The aim is to analyze the efficiency of a single-phase 9-level cascaded CHB MLI using three distinct switch configurations: 16-switch, 11-switch, and proposed 8-switch. The calculated switching angles are optimized using the feed-forward methodology. Two types of load conditions—R load and R-L load—are being examined. The results suggest that the proposed 8-switch design exhibits superior efficiency by limiting power losses compared to other topologies. Regarding THD, the conventional topology yields a somewhat lower value, however, the disparity is less than 1% when compared to both reduced switch topologies.
- Open Access
- 1 June 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 14 (3) , 3342-3349
Multiple faults detection in doubly-fed induction generator wind turbine using artificial neural network
The development of fault detection methods in wind turbine (WT), especially for single fault detection, is continuously increasing. However, the rapid growth of fault detection in WT leads to another challenge where multiple faults can occur. The single fault detection method in WT is no longer reliable, especially when multiple faults occur simultaneously. Therefore, multiple faults detection in doubly-fed induction generators (DFIG) WT was proposed using an artificial neural networks (ANN) model. These multiple faults include internal and external stator faults happening simultaneously. Internal stator faults cover inter-turn short circuit faults and open circuit faults, while external stator faults cover loss of excitation and external short circuit faults. The performance of the developed multiple faults detection model was measured using accuracy and the root mean square error (RMSE) value. The results show that the developed model performs well with high accuracy and a low RMSE value. Thus, the developed model can accurately detect the coexistence of multiple faults in DFIG WT.
- 1 June 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 14 (3) , 3342-3349
Open AccessMultiple faults detection in doubly-fed induction generator wind turbine using artificial neural network
The development of fault detection methods in wind turbine (WT), especially for single fault detection, is continuously increasing. However, the rapid growth of fault detection in WT leads to another challenge where multiple faults can occur. The single fault detection method in WT is no longer reliable, especially when multiple faults occur simultaneously. Therefore, multiple faults detection in doubly-fed induction generators (DFIG) WT was proposed using an artificial neural networks (ANN) model. These multiple faults include internal and external stator faults happening simultaneously. Internal stator faults cover inter-turn short circuit faults and open circuit faults, while external stator faults cover loss of excitation and external short circuit faults. The performance of the developed multiple faults detection model was measured using accuracy and the root mean square error (RMSE) value. The results show that the developed model performs well with high accuracy and a low RMSE value. Thus, the developed model can accurately detect the coexistence of multiple faults in DFIG WT.
- Open Access
- 1 May 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1878 (1) , 012039
Fault Detection Analysis for Three Phase Induction Motor Drive System using Neural Network
One of the most important components of the industrial process is known to be the three-phase induction motor. This device, however, is prone to electrical and mechanical faults, which may cause a substantial component or financial losses. The fault analysis received growing attention due to a need to increase reliability and to decrease potential output loss due to machine breakdown. Thus, the purpose of this paper is to present a simple and reliable fault analysis based on the Neural Network (NN) is proposed. The NN method is a simpler approach without a diagnostic professional to review data and diagnose issues. Various fault disputes of induction motor are developed and analysed using the NN method. The main types of faults considered are over-voltage, under-voltage, and unbalanced voltage faults. The trained network is tested with simulated fault current and voltage data.
- 1 May 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1878 (1) , 012039
Open AccessFault Detection Analysis for Three Phase Induction Motor Drive System using Neural Network
One of the most important components of the industrial process is known to be the three-phase induction motor. This device, however, is prone to electrical and mechanical faults, which may cause a substantial component or financial losses. The fault analysis received growing attention due to a need to increase reliability and to decrease potential output loss due to machine breakdown. Thus, the purpose of this paper is to present a simple and reliable fault analysis based on the Neural Network (NN) is proposed. The NN method is a simpler approach without a diagnostic professional to review data and diagnose issues. Various fault disputes of induction motor are developed and analysed using the NN method. The main types of faults considered are over-voltage, under-voltage, and unbalanced voltage faults. The trained network is tested with simulated fault current and voltage data.