Riccardo Finamore
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Riccardo Finamore has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Selene Barone
School of Dentistry, Department of Health Sciences, Magna Graecia University of Catanzaro, Viale Europa, 88100 Catanzaro, Italy
4 shared publications - Alessandro Antonelli
Department of Health Sciences, Magna Graecia University of Catanzaro, 88100 Catanzaro, Italy
3 shared publications - Amerigo Giudice
Dentistry Unit, Department of Health Sciences University of Catanzaro “Magna Graecia” Catanzaro Italy
3 shared publications - Antonio Madonna
Department of Health Sciences, School of Dentistry, Magna Graecia University of Catanzaro, 88100 Catanzaro, Italy
2 shared publications - Francesco Bennardo
School of Dentistry, Department of Health Sciences, Magna Graecia University of Catanzaro, Viale Europa, 88100 Catanzaro, Italy
2 shared publications - Marianna Salviati
School of Dentistry, Department of Health Sciences, Magna Graecia University of Catanzaro, Catanzaro, Italy
2 shared publications
Latest Publications
- Open Access
- 29 October 2026
- Published by MDPI AG in Dentistry Journal
- Vol. 14 (11) , 703
Primary Stability of an Expandable Versus a Conventional Short Implant in Low-Density Bone: A Density-Stratified Ex Vivo Comparison
Background: Rehabilitation of atrophic posterior jaws is often challenging due to anatomical limitations, frequently requiring bone augmentation procedures or the use of short implants. Expandable short implants are characterized by an expansion mechanism whose potential contribution to primary stability remains to be fully established. This ex vivo study compared the primary stability of expandable and conventional short implants in porcine rib bone of low and intermediate CBCT-defined density (corresponding approximately to Misch D4 and D3). Methods: A total of 68 implants were placed in 17 fresh porcine ribs, using a randomized complete block design: 34 expandable short implants (ESI; Pyramidion, Ø4.1 × 5 mm) and 34 conventional short implants (CSI; Osstem TS III, Ø4 × 7 mm), equally distributed between two CBCT-defined density strata (D3 and D4, operationally defined). Peak insertion torque (PIT), resonance frequency analysis (ISQ; before and after apical expansion for the ESI group), peak removal torque (PRT), and expansion torque (ESI group only) were recorded. Data were analyzed using a two-way ANOVA (implant group × bone density) with a Bonferroni-corrected significance threshold (α = 0.025) for the two primary outcomes, ISQ and PRT. Results: PIT did not differ significantly between groups in D3 bone, while CSI showed higher PIT in D4 bone (p = 0.0005). ISQ increased significantly following apical expansion in the ESI group (mean + 4.91, 95% CI 3.60 to 6.22; p = 0.0004), more markedly in D4 than D3 bone; final ISQ did not differ significantly between groups at either bone density. PRT was higher in the ESI group in both density strata (p = 0.0004 in D3 and p = 0.0003 in D4), with no significant implant group × bone density interaction. Incomplete apical expansion occurred in 3 of 34 ESI implants, all in D3 bone. Conclusions: In this ex vivo model, no statistically significant difference in final ISQ was detected between the expandable and conventional short implants, and removal torque was higher for the expandable implant across both bone densities; equivalence was not tested. These findings refer to the initial mechanical behaviour under the tested ex vivo conditions, without implying superiority over conventional implant designs; further studies are warranted.
- 29 October 2026
- Published by MDPI AG in Dentistry Journal
- Vol. 14 (11) , 703
Open AccessPrimary Stability of an Expandable Versus a Conventional Short Implant in Low-Density Bone: A Density-Stratified Ex Vivo Comparison
Background: Rehabilitation of atrophic posterior jaws is often challenging due to anatomical limitations, frequently requiring bone augmentation procedures or the use of short implants. Expandable short implants are characterized by an expansion mechanism whose potential contribution to primary stability remains to be fully established. This ex vivo study compared the primary stability of expandable and conventional short implants in porcine rib bone of low and intermediate CBCT-defined density (corresponding approximately to Misch D4 and D3). Methods: A total of 68 implants were placed in 17 fresh porcine ribs, using a randomized complete block design: 34 expandable short implants (ESI; Pyramidion, Ø4.1 × 5 mm) and 34 conventional short implants (CSI; Osstem TS III, Ø4 × 7 mm), equally distributed between two CBCT-defined density strata (D3 and D4, operationally defined). Peak insertion torque (PIT), resonance frequency analysis (ISQ; before and after apical expansion for the ESI group), peak removal torque (PRT), and expansion torque (ESI group only) were recorded. Data were analyzed using a two-way ANOVA (implant group × bone density) with a Bonferroni-corrected significance threshold (α = 0.025) for the two primary outcomes, ISQ and PRT. Results: PIT did not differ significantly between groups in D3 bone, while CSI showed higher PIT in D4 bone (p = 0.0005). ISQ increased significantly following apical expansion in the ESI group (mean + 4.91, 95% CI 3.60 to 6.22; p = 0.0004), more markedly in D4 than D3 bone; final ISQ did not differ significantly between groups at either bone density. PRT was higher in the ESI group in both density strata (p = 0.0004 in D3 and p = 0.0003 in D4), with no significant implant group × bone density interaction. Incomplete apical expansion occurred in 3 of 34 ESI implants, all in D3 bone. Conclusions: In this ex vivo model, no statistically significant difference in final ISQ was detected between the expandable and conventional short implants, and removal torque was higher for the expandable implant across both bone densities; equivalence was not tested. These findings refer to the initial mechanical behaviour under the tested ex vivo conditions, without implying superiority over conventional implant designs; further studies are warranted.
- 9 January 2026
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 28 (1) , e70117
Influence of ZAGA Classification on the Accuracy of 150 Digitally Planned Zygomatic Implants Placement
Aim: This 3D analysis assessed the accuracy of zygomatic implant (ZI) placement using a static surgical guide in correlation with ZAGA classification and the rehabilitation type. Methods: Pre‐surgical CT scans were used to create a virtual surgical plane, exported as .stl files, and to define the ZAGA classification of each implant. A CT scan was taken 6 months post‐surgery, and segmentation of the zygomatic implants was performed. The 3D analysis on 3DSlicer software compared planned and placed zygomatic implants, measuring linear and angular displacements at the apex and base of each model. Displacements were correlated with the ZAGA classification and the type of rehabilitation (if quad, twin, or mono zygomatic implant). Results: The study included 45 patients and 150 zygomatic implants, all placed using bone‐supported surgical guides with no bone modifications. The implant survival rate was 100% at 6 months. Most patients received quad rehabilitation with 4 implants, and there was strong overlap between planned and placed implants. The mean surface displacement was 0.43 mm on the right and 0.45 mm on the left. The angular deviation between the planned and placed implant orientations was lower than 1° for both the anterior and posterior implants. According to ZAGA classification, surface displacement increased from class 0 to 4. No significant differences were found among the type of rehabilitation ( p > 0.289). Conclusion: The study highlights the accuracy of fully guided surgery for zygomatic implant placement, recommending its consideration in clinical decision‐making. It also shows greater accuracy in lower ZAGA classes and no significant difference across rehabilitation types.
- 9 January 2026
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 28 (1) , e70117
Influence of ZAGA Classification on the Accuracy of 150 Digitally Planned Zygomatic Implants Placement
Aim: This 3D analysis assessed the accuracy of zygomatic implant (ZI) placement using a static surgical guide in correlation with ZAGA classification and the rehabilitation type. Methods: Pre‐surgical CT scans were used to create a virtual surgical plane, exported as .stl files, and to define the ZAGA classification of each implant. A CT scan was taken 6 months post‐surgery, and segmentation of the zygomatic implants was performed. The 3D analysis on 3DSlicer software compared planned and placed zygomatic implants, measuring linear and angular displacements at the apex and base of each model. Displacements were correlated with the ZAGA classification and the type of rehabilitation (if quad, twin, or mono zygomatic implant). Results: The study included 45 patients and 150 zygomatic implants, all placed using bone‐supported surgical guides with no bone modifications. The implant survival rate was 100% at 6 months. Most patients received quad rehabilitation with 4 implants, and there was strong overlap between planned and placed implants. The mean surface displacement was 0.43 mm on the right and 0.45 mm on the left. The angular deviation between the planned and placed implant orientations was lower than 1° for both the anterior and posterior implants. According to ZAGA classification, surface displacement increased from class 0 to 4. No significant differences were found among the type of rehabilitation ( p > 0.289). Conclusion: The study highlights the accuracy of fully guided surgery for zygomatic implant placement, recommending its consideration in clinical decision‐making. It also shows greater accuracy in lower ZAGA classes and no significant difference across rehabilitation types.
- Open Access
- 3 November 2025
- Published by MDPI AG in Dentistry Journal
- Vol. 13 (11) , 512
Diagnostic Performance of Autofluorescence for Oral Lesions: A Comparison Between a Postgraduate and an Expert Clinician
Background/Objectives: Autofluorescence (AF) is a widely used adjunctive tool in the detection of oral potentially malignant disorders (OPMDs) and malignant lesions, but its performance can be influenced by clinicians’ experiences. This study aimed to examine how AF influences diagnostic decision-making and performances of a novice clinician compared with those of an experienced examiner. Methods: A total of 80 patients with oral lesions participated in this cross-sectional study. Each underwent a standard oral examination (OE) followed by an assessment with the VELscope® System Vx (LED Medical Diagnostics Inc., Burnaby, BC, Canada), independently conducted by an expert clinician (E) and a postgraduate dentist (PD), both blinded to each other’s results. Biopsy and histopathological analysis provided the reference diagnosis. After every examination, lesions were categorized as either “Risk of Malignancy” (RM) or “No Risk of Malignancy” (NRM). Results: Based on OE, PD identified 39 RM lesions, while E 29. AF with VELscope® identified an additional 12 RM lesions for the PD and 7 for the E that were not suspected on OE alone. Combining OE with VELscope® improved sensitivity (PD: 90.9%; E: 95.4%) and negative predictive value (PD: 91.7%; E: 97.6%), while decreasing specificity (PD: 37.9%; E: 70.7%) and positive predictive value (PD: 35.7%; E: 55.3%) compared with OE alone. Conclusions: AF increases diagnostic sensitivity, particularly for less experienced clinicians, while offering moderate advantages for experts. Nevertheless, the corresponding decline in specificity emphasizes the need for cautious interpretation. AF should be incorporated as a complementary tool within structured diagnostic pathways, accompanied by adequate training, and cannot replace histopathological confirmation or clinical expertise.
- 3 November 2025
- Published by MDPI AG in Dentistry Journal
- Vol. 13 (11) , 512
Open AccessDiagnostic Performance of Autofluorescence for Oral Lesions: A Comparison Between a Postgraduate and an Expert Clinician
Background/Objectives: Autofluorescence (AF) is a widely used adjunctive tool in the detection of oral potentially malignant disorders (OPMDs) and malignant lesions, but its performance can be influenced by clinicians’ experiences. This study aimed to examine how AF influences diagnostic decision-making and performances of a novice clinician compared with those of an experienced examiner. Methods: A total of 80 patients with oral lesions participated in this cross-sectional study. Each underwent a standard oral examination (OE) followed by an assessment with the VELscope® System Vx (LED Medical Diagnostics Inc., Burnaby, BC, Canada), independently conducted by an expert clinician (E) and a postgraduate dentist (PD), both blinded to each other’s results. Biopsy and histopathological analysis provided the reference diagnosis. After every examination, lesions were categorized as either “Risk of Malignancy” (RM) or “No Risk of Malignancy” (NRM). Results: Based on OE, PD identified 39 RM lesions, while E 29. AF with VELscope® identified an additional 12 RM lesions for the PD and 7 for the E that were not suspected on OE alone. Combining OE with VELscope® improved sensitivity (PD: 90.9%; E: 95.4%) and negative predictive value (PD: 91.7%; E: 97.6%), while decreasing specificity (PD: 37.9%; E: 70.7%) and positive predictive value (PD: 35.7%; E: 55.3%) compared with OE alone. Conclusions: AF increases diagnostic sensitivity, particularly for less experienced clinicians, while offering moderate advantages for experts. Nevertheless, the corresponding decline in specificity emphasizes the need for cautious interpretation. AF should be incorporated as a complementary tool within structured diagnostic pathways, accompanied by adequate training, and cannot replace histopathological confirmation or clinical expertise.
- Open Access
- 3 June 2024
- Published by MDPI AG in Dentistry Journal
- Vol. 12 (6) , 167
Concordance Analysis of Lower Third Molar Surgery Classifications: A Comparative Study
The high frequency and complexity of mandibular third molar (M3M) surgery have led several authors to the development of classification systems for better evaluation and management in oral surgery. This study compared the classifications of Juodzabalys and Daugela et al. (JD), Sammartino et al., Chang et al., Jhamb et al., Maglione et al., and Nemsi et al. to understand the concordance between the scores of M3M surgery. Two types of analysis were conducted: the relationship between the M3M and the inferior alveolar nerve (IAN), and the overall difficulty score based on the tooth’s angulation and its spatial position with the adjacent structure. The analysis of the classifications on the relationship between M3M and IAN resulted in a concordance of 26.1%. In the pairwise comparisons, the classifications of Nemsi et al. and Jhamb et al. showed the highest concordance of 59.5%. Analyzing the total scores difficulty, the JD et al., Chang et al., and Sammartino et al. classifications demonstrated a concordance level of 25.5%. A pairwise assessment revealed a higher concordance degree between the classifications of Sammartino et al. and Chang et al. (57.4%). The results highlight the limits in establishing a comprehensive and objective classification for the surgical difficulty of M3M, possibly attributed to variations in the methodology for computing total scores. An objective, automated, and non-operator-dependent classification method for assessing the surgical difficulty of M3M is still needed.
- 3 June 2024
- Published by MDPI AG in Dentistry Journal
- Vol. 12 (6) , 167
Open AccessConcordance Analysis of Lower Third Molar Surgery Classifications: A Comparative Study
The high frequency and complexity of mandibular third molar (M3M) surgery have led several authors to the development of classification systems for better evaluation and management in oral surgery. This study compared the classifications of Juodzabalys and Daugela et al. (JD), Sammartino et al., Chang et al., Jhamb et al., Maglione et al., and Nemsi et al. to understand the concordance between the scores of M3M surgery. Two types of analysis were conducted: the relationship between the M3M and the inferior alveolar nerve (IAN), and the overall difficulty score based on the tooth’s angulation and its spatial position with the adjacent structure. The analysis of the classifications on the relationship between M3M and IAN resulted in a concordance of 26.1%. In the pairwise comparisons, the classifications of Nemsi et al. and Jhamb et al. showed the highest concordance of 59.5%. Analyzing the total scores difficulty, the JD et al., Chang et al., and Sammartino et al. classifications demonstrated a concordance level of 25.5%. A pairwise assessment revealed a higher concordance degree between the classifications of Sammartino et al. and Chang et al. (57.4%). The results highlight the limits in establishing a comprehensive and objective classification for the surgical difficulty of M3M, possibly attributed to variations in the methodology for computing total scores. An objective, automated, and non-operator-dependent classification method for assessing the surgical difficulty of M3M is still needed.