Adina Milena Tatar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Adina Milena Tatar has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Dragos Pasculescu
Automation, Computer, Electrical and Power Department, University of Petrosani, 332006 Petrosani, Romania
5 shared publications - Teodora Lazar
Automation, Computer, Electrical and Power Department, University of Petrosani, 332006 Petrosani, Romania
5 shared publications - Dan Cristian Lazar
Automation, Computer, Electrical and Power Department, University of Petrosani, 332006 Petrosani, Romania
3 shared publications - Daria Ionescu
Industrial Engineering and Management Department, University of Petrosani, 332006 Petrosani, Romania
3 shared publications - Florin Gabriel Popescu
Automation, Computer, Electrical and Power Department, University of Petrosani, 332006 Petrosani, Romania
2 shared publications - Georgeta Buica
Electrical and Mechanical Risks Laboratory, INCDPM “Alexandru Darabont”, 35A Blvd Ghencea, 6th County, 062692 Bucharest, Romania
2 shared publications
Latest Publications
- Open Access
- 30 September 2026
- Published by MDPI AG in Electronics
- Vol. 15 (19) , 4487
Transformer Inrush Mitigation and Sequential Load Restoration in a Hybrid PV–BESS Microgrid Using Grid-Forming Black-Start Control—Case Study of a 31.59 MWp Photovoltaic Plant
Hybrid PV–BESS microgrids represent a promising solution for enhancing energy resilience; however, the implementation of black-start functions in such architectures remains a complex challenge, particularly in the presence of medium-voltage transformers and grid-following photovoltaic sources. This paper proposes and evaluates, through MATLAB/Simulink simulation, a black-start strategy for a hybrid microgrid derived from the architecture of a real 31.59 MWp photovoltaic power plant connected through a 20 kV collector network. The strategy is based on a BESS operated in grid-forming mode, responsible for voltage and frequency formation, controlled energization of the internal infrastructure, and support of the initial restoration stages, while the photovoltaic groups are synchronized at a later stage in order to reduce the energy burden imposed on the storage system. The methodology combines controlled voltage ramping for transformer inrush current mitigation, hybrid PV–BESS restoration, robustness evaluation under irradiance variation, sequential load restoration, and staged energization of the internal stations TS1–TS5. The results show that the soft-start strategy reduces the maximum instantaneous current of transformer TS2 from 188.3620 A to 0.3515 A and the maximum current of the BESS source from 4729.2 A to 57.7929 A. In the hybrid scenario, after photovoltaic source synchronization at 7 s, PV power rises to 2.75 MW, while the power supplied by the BESS decreases from 3.00 MW to 0.25 MW. The analysis of irradiance variation confirms the increased energy dependence on the BESS under reduced solar resource conditions, while sequential load restoration demonstrates the feasibility of controlled reconnection up to 30.25 MW. Overall, the study confirms that the proposed architecture and staged control logic provide a feasible and transferable framework for enhancing the resilience of large-scale photovoltaic power plants based on hybrid PV–BESS microgrids.
- 30 September 2026
- Published by MDPI AG in Electronics
- Vol. 15 (19) , 4487
Open AccessTransformer Inrush Mitigation and Sequential Load Restoration in a Hybrid PV–BESS Microgrid Using Grid-Forming Black-Start Control—Case Study of a 31.59 MWp Photovoltaic Plant
Hybrid PV–BESS microgrids represent a promising solution for enhancing energy resilience; however, the implementation of black-start functions in such architectures remains a complex challenge, particularly in the presence of medium-voltage transformers and grid-following photovoltaic sources. This paper proposes and evaluates, through MATLAB/Simulink simulation, a black-start strategy for a hybrid microgrid derived from the architecture of a real 31.59 MWp photovoltaic power plant connected through a 20 kV collector network. The strategy is based on a BESS operated in grid-forming mode, responsible for voltage and frequency formation, controlled energization of the internal infrastructure, and support of the initial restoration stages, while the photovoltaic groups are synchronized at a later stage in order to reduce the energy burden imposed on the storage system. The methodology combines controlled voltage ramping for transformer inrush current mitigation, hybrid PV–BESS restoration, robustness evaluation under irradiance variation, sequential load restoration, and staged energization of the internal stations TS1–TS5. The results show that the soft-start strategy reduces the maximum instantaneous current of transformer TS2 from 188.3620 A to 0.3515 A and the maximum current of the BESS source from 4729.2 A to 57.7929 A. In the hybrid scenario, after photovoltaic source synchronization at 7 s, PV power rises to 2.75 MW, while the power supplied by the BESS decreases from 3.00 MW to 0.25 MW. The analysis of irradiance variation confirms the increased energy dependence on the BESS under reduced solar resource conditions, while sequential load restoration demonstrates the feasibility of controlled reconnection up to 30.25 MW. Overall, the study confirms that the proposed architecture and staged control logic provide a feasible and transferable framework for enhancing the resilience of large-scale photovoltaic power plants based on hybrid PV–BESS microgrids.
- Top Cited PapersOpen Access
Impact of Triplen Harmonics Generated by Modern Non-Linear Loads on Neutral Conductor Overheating in Low-Voltage Smart Buildings
The rapid proliferation of single-phase non-linear loads, such as LED lighting and IT equipment, in modern Smart Buildings has introduced significant power quality challenges in low-voltage electrical installations. A critical but often underestimated consequence is the severe overloading of the neutral conductor caused by triplen harmonics (particularly the 3rd harmonic), which sum algebraically even in balanced three-phase systems. This paper analyzes the electrical and thermal impact of these distortions using a detailed MATLAB/Simulink model of a 400/230 V (3P + N) network. The simulation results demonstrate that under highly distorted conditions (Scenario S3), the neutral current can reach 180% of the nominal phase current (18 A vs. 10 A). Furthermore, the Joule losses analysis reveals a thermal stress more than three times higher on the neutral conductor (peak ~65 W) compared to the phase conductor (~20 W), challenging the traditional design practice of neutral undersizing. To address these safety issues, this study proposes a novel neutral-to-phase current ratio index (kN) and a proactive decision matrix for Building Management Systems (BMS). Unlike traditional mitigation strategies that rely on static hardware oversizing, passive filters, or specialized transformers, the proposed approach offers a dynamic, cost-effective, and software-driven solution that can be easily integrated into the existing automation infrastructure of modern Smart Buildings. The model identifies a critical tipping point at a 3rd harmonic content of 35.3%, where kN ≥ 1. By continuously monitoring the kN parameter, the proposed algorithm enables a transition from passive protection to active power management, triggering automated responses to prevent insulation degradation and mitigate fire hazards.
Top Cited PapersOpen AccessImpact of Triplen Harmonics Generated by Modern Non-Linear Loads on Neutral Conductor Overheating in Low-Voltage Smart Buildings
The rapid proliferation of single-phase non-linear loads, such as LED lighting and IT equipment, in modern Smart Buildings has introduced significant power quality challenges in low-voltage electrical installations. A critical but often underestimated consequence is the severe overloading of the neutral conductor caused by triplen harmonics (particularly the 3rd harmonic), which sum algebraically even in balanced three-phase systems. This paper analyzes the electrical and thermal impact of these distortions using a detailed MATLAB/Simulink model of a 400/230 V (3P + N) network. The simulation results demonstrate that under highly distorted conditions (Scenario S3), the neutral current can reach 180% of the nominal phase current (18 A vs. 10 A). Furthermore, the Joule losses analysis reveals a thermal stress more than three times higher on the neutral conductor (peak ~65 W) compared to the phase conductor (~20 W), challenging the traditional design practice of neutral undersizing. To address these safety issues, this study proposes a novel neutral-to-phase current ratio index (kN) and a proactive decision matrix for Building Management Systems (BMS). Unlike traditional mitigation strategies that rely on static hardware oversizing, passive filters, or specialized transformers, the proposed approach offers a dynamic, cost-effective, and software-driven solution that can be easily integrated into the existing automation infrastructure of modern Smart Buildings. The model identifies a critical tipping point at a 3rd harmonic content of 35.3%, where kN ≥ 1. By continuously monitoring the kN parameter, the proposed algorithm enables a transition from passive protection to active power management, triggering automated responses to prevent insulation degradation and mitigate fire hazards.
- Open Access
Real-Time Energy System Optimization and Resilience Analysis in Low-Voltage Networks Using Intelligent Edge Computing
The transition toward active distribution networks requires advanced control solutions capable of handling the rapid dynamics of distributed energy resources. This paper proposes a low-cost, intelligent IoT architecture designed for the real-time optimization and analysis of energy systems within low-voltage networks. Unlike centralized monitoring approaches constrained by communication latency, the proposed solution leverages Intelligent Edge Processing (IEP) implemented on ESP32 embedded nodes to optimize data flow and decision-making. This architecture executes stability assessments directly at the network edge, calculating critical analysis indicators such as the Voltage Deviation Index (VDI) and Rate of Change of Frequency (RoCoF). The system was validated on the CIGRE European LV benchmark under severe stress scenarios, including rapid solar transients and voltage sags. The results demonstrate that the proposed architecture effectively coordinates storage interventions, ensuring voltage recovery within 300 ms and maintaining power quality within EN 50160 limits even during severe voltage sags. The study validates the feasibility of using industrial IoT edge computing as a resilient, non-wire alternative for modernizing complex energy systems.
Open AccessReal-Time Energy System Optimization and Resilience Analysis in Low-Voltage Networks Using Intelligent Edge Computing
The transition toward active distribution networks requires advanced control solutions capable of handling the rapid dynamics of distributed energy resources. This paper proposes a low-cost, intelligent IoT architecture designed for the real-time optimization and analysis of energy systems within low-voltage networks. Unlike centralized monitoring approaches constrained by communication latency, the proposed solution leverages Intelligent Edge Processing (IEP) implemented on ESP32 embedded nodes to optimize data flow and decision-making. This architecture executes stability assessments directly at the network edge, calculating critical analysis indicators such as the Voltage Deviation Index (VDI) and Rate of Change of Frequency (RoCoF). The system was validated on the CIGRE European LV benchmark under severe stress scenarios, including rapid solar transients and voltage sags. The results demonstrate that the proposed architecture effectively coordinates storage interventions, ensuring voltage recovery within 300 ms and maintaining power quality within EN 50160 limits even during severe voltage sags. The study validates the feasibility of using industrial IoT edge computing as a resilient, non-wire alternative for modernizing complex energy systems.
- Open Access
Intelligent Modeling of PV–BESS Microgrids for Enhanced Stability, Cyber–Physical Resilience and Blackout Prevention
This paper proposes and validates a method for assessing the resilience of cyber–physical microgrids integrating Photovoltaic (PV) generation and Battery Energy Storage Systems (BESS). The approach combines two operational performance indicators—Voltage Deviation Index (VDI) and Energy Not Supplied (ENS)—with a composite resilience index that captures recovery dynamics following physical and cyber disturbances. The method is implemented in MATLAB Simulink R2022b on the IEEE 33-bus feeder, with PV at bus 6 and a BESS at bus 18. Two stress scenarios are analyzed: (i) loss of the main supply at bus 2 and (ii) a cyber-induced communication failure that triggers local (fallback) operation. Compared with the base case, the proposed strategy reduces VDI by approximately 27% and ENS by 12%, demonstrating significantly improved resilience without noticeable performance penalties.
Open AccessIntelligent Modeling of PV–BESS Microgrids for Enhanced Stability, Cyber–Physical Resilience and Blackout Prevention
This paper proposes and validates a method for assessing the resilience of cyber–physical microgrids integrating Photovoltaic (PV) generation and Battery Energy Storage Systems (BESS). The approach combines two operational performance indicators—Voltage Deviation Index (VDI) and Energy Not Supplied (ENS)—with a composite resilience index that captures recovery dynamics following physical and cyber disturbances. The method is implemented in MATLAB Simulink R2022b on the IEEE 33-bus feeder, with PV at bus 6 and a BESS at bus 18. Two stress scenarios are analyzed: (i) loss of the main supply at bus 2 and (ii) a cyber-induced communication failure that triggers local (fallback) operation. Compared with the base case, the proposed strategy reduces VDI by approximately 27% and ENS by 12%, demonstrating significantly improved resilience without noticeable performance penalties.
- Open Access
- 13 November 2025
- Published by MDPI AG in Preprints.org
Intelligent Modeling of PV – BESS Microgrids for Enhanced Stability, Cyber–Physical Resilience and Blackout Prevention
This paper proposes and validates a method for assessing the resilience of cyber–physical microgrids integrating Photovoltaic (PV) generation and Battery Energy Storage Systems (BESS). The approach combines two operational performance indicators—Voltage Deviation Index (VDI) and Energy Not Supplied (ENS)—with a composite resilience index that captures recovery dynamics following physical and cyber disturbances. The method is implemented in MATLAB Simulink on the IEEE 33-bus feeder, with PV at bus 6 and a BESS at bus 18. Two stress scenarios are analyzed: (i) loss of the main supply at bus 2 and (ii) a cyber-induced communication failure that triggers local (fallback) operation. Compared with the base case, the proposed strategy reduces VDI by approximately 27% and ENS by 12%, demonstrating significantly improved resilience without noticeable performance penalties.
- 13 November 2025
- Published by MDPI AG in Preprints.org
Open AccessIntelligent Modeling of PV – BESS Microgrids for Enhanced Stability, Cyber–Physical Resilience and Blackout Prevention
This paper proposes and validates a method for assessing the resilience of cyber–physical microgrids integrating Photovoltaic (PV) generation and Battery Energy Storage Systems (BESS). The approach combines two operational performance indicators—Voltage Deviation Index (VDI) and Energy Not Supplied (ENS)—with a composite resilience index that captures recovery dynamics following physical and cyber disturbances. The method is implemented in MATLAB Simulink on the IEEE 33-bus feeder, with PV at bus 6 and a BESS at bus 18. Two stress scenarios are analyzed: (i) loss of the main supply at bus 2 and (ii) a cyber-induced communication failure that triggers local (fallback) operation. Compared with the base case, the proposed strategy reduces VDI by approximately 27% and ENS by 12%, demonstrating significantly improved resilience without noticeable performance penalties.
- Open Access
- 1 August 2025
- Published by MDPI AG in Preprints.org
8D Analysis Method and Quality Planning for Optimizing Problem Solving in the Automotive Sector: Case Study
The demand for advanced technology and superior quality in the automotive industry has become essential. Continuous evolution requires a rigorous analysis of every step taken. Customers demand high performance in technology, design, digitalization, and, of course, quality at a competitive price. To meet these expectations, engineers ensure transparency and trust at every stage of the project, guaranteeing flawless execution. This paper aims to highlight a clear and transparent approach to the 8D analysis method, demonstrating its effectiveness in identifying and solving engineering problems. Furthermore, quality planning and 8D analysis are fundamental pillars of quality management in the automotive industry. To ensure a comprehensive and well-founded approach, the paper combines several research methods: a review of the specialized literature, a hypothetical case study approach, and comparative analysis. The proposed methodology allows for a deep understanding of the concepts addressed, facilitating their applicability in real situations. The main conclusions drawn from the research are that quality planning in an automotive buckle development project has proven to be an essential and complex process, directly influencing the success of the project, the safety of end users, and their satisfaction. The analysis of the implementation of the quality planning process, as previously described, has highlighted several fundamental aspects that must be considered to ensure the success and performance of such a project.
- 1 August 2025
- Published by MDPI AG in Preprints.org
Open Access8D Analysis Method and Quality Planning for Optimizing Problem Solving in the Automotive Sector: Case Study
The demand for advanced technology and superior quality in the automotive industry has become essential. Continuous evolution requires a rigorous analysis of every step taken. Customers demand high performance in technology, design, digitalization, and, of course, quality at a competitive price. To meet these expectations, engineers ensure transparency and trust at every stage of the project, guaranteeing flawless execution. This paper aims to highlight a clear and transparent approach to the 8D analysis method, demonstrating its effectiveness in identifying and solving engineering problems. Furthermore, quality planning and 8D analysis are fundamental pillars of quality management in the automotive industry. To ensure a comprehensive and well-founded approach, the paper combines several research methods: a review of the specialized literature, a hypothetical case study approach, and comparative analysis. The proposed methodology allows for a deep understanding of the concepts addressed, facilitating their applicability in real situations. The main conclusions drawn from the research are that quality planning in an automotive buckle development project has proven to be an essential and complex process, directly influencing the success of the project, the safety of end users, and their satisfaction. The analysis of the implementation of the quality planning process, as previously described, has highlighted several fundamental aspects that must be considered to ensure the success and performance of such a project.
- 31 March 2024
- Published by Editura Thoth in Journal of Research and Innovation for Sustainable Society
- Vol. 6 (1)
SINTERED MATERIALS TESTING IN LAW TEMPERATURE
- 31 March 2024
- Published by Editura Thoth in Journal of Research and Innovation for Sustainable Society
- Vol. 6 (1)
SINTERED MATERIALS TESTING IN LAW TEMPERATURE