Lu Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lu Zhang has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Chenglin Chu
School of Materials Science and Engineering, Southeast University, Nanjing 211189, China
2 shared publications - Feng Xue
School of Materials Science and Engineering, Southeast University, Nanjing 211189, China
2 shared publications - Jing Bai
School of Materials Science and Engineering Southeast University Nanjing China
2 shared publications - Chao Guo
Southeast University, Nanjing, China
1 shared publication - Cheng Wang
School of Materials Science and Engineering, Southeast University, Nanjing 211189, China
1 shared publication - Feiyang Wang
Department of Orthodontics, The Affiliated Stomatological Hospital of Nanjing Medical University, Nanjing 210029, China
1 shared publication
Latest Publications
- Open Access
Self-Healing Coating with Ultrasound-Triggered On-Demand Osthole Release for Magnesium-Based Orthopedic Implants
Magnesium alloys exhibit promising application prospects in medical orthopedic implants. However, their practical applications are limited by rapid corrosion, suboptimal osseointegration, and implant-related infections. Although conventional drug-eluting polymer coatings can provide various biological functions, the uncontrolled drug release often compromises long-term therapeutic efficacy. In this study, a self-healing Mg-poly(ε-caprolactone) (PCL)@OHF coating is designed and prepared on WE43 Mg by spin coating to achieve ultrasound-triggered release of osthole. OHF consists of osthole-loaded hollow mesoporous silica nanoparticles (HMSs) modified with Pluronic F127. Drug release studies show that the nanocapsules respond to ultrasound stimulation, with the cumulative release increasing from 39.94% to 75.93% after 7 days. Furthermore, the coating demonstrates intrinsic self-healing capacity upon thermal treatment at 50 °C. Electrochemical and immersion tests reveal that the composite coating provides good barrier protection for the WE43 Mg alloy, evidenced by a decrease in corrosion current density from 2.04 × 10−6 to 5.94 × 10−7 A/cm2. In vitro biological assays confirm the antibacterial efficacy against Staphylococcus aureus and Escherichia coli, as well as the ability to promote osteogenic differentiation. The results reveal a surface modification strategy that combines self-healing, anticorrosion, and on-demand drug release, offering a promising approach for advanced orthopedic implants.
Open AccessSelf-Healing Coating with Ultrasound-Triggered On-Demand Osthole Release for Magnesium-Based Orthopedic Implants
Magnesium alloys exhibit promising application prospects in medical orthopedic implants. However, their practical applications are limited by rapid corrosion, suboptimal osseointegration, and implant-related infections. Although conventional drug-eluting polymer coatings can provide various biological functions, the uncontrolled drug release often compromises long-term therapeutic efficacy. In this study, a self-healing Mg-poly(ε-caprolactone) (PCL)@OHF coating is designed and prepared on WE43 Mg by spin coating to achieve ultrasound-triggered release of osthole. OHF consists of osthole-loaded hollow mesoporous silica nanoparticles (HMSs) modified with Pluronic F127. Drug release studies show that the nanocapsules respond to ultrasound stimulation, with the cumulative release increasing from 39.94% to 75.93% after 7 days. Furthermore, the coating demonstrates intrinsic self-healing capacity upon thermal treatment at 50 °C. Electrochemical and immersion tests reveal that the composite coating provides good barrier protection for the WE43 Mg alloy, evidenced by a decrease in corrosion current density from 2.04 × 10−6 to 5.94 × 10−7 A/cm2. In vitro biological assays confirm the antibacterial efficacy against Staphylococcus aureus and Escherichia coli, as well as the ability to promote osteogenic differentiation. The results reveal a surface modification strategy that combines self-healing, anticorrosion, and on-demand drug release, offering a promising approach for advanced orthopedic implants.
- Open Access
Effects of Dynamic Flow Rates on the In Vitro Bio-Corrosion Behavior of Zn-Cu Alloy
In the complicated real physiological environment in vivo, body fluids and blood are constantly replenished and move dynamically, and therefore, the dynamic impacts of bodily fluids and blood need to be considered in the evaluation of biodegradable materials. However, little research has been conducted on the impact of dynamic flowing circumstances on the corrosion characteristics of zinc-based alloys, particularly at high flow rates. The effects of various flow rates on the bio-corrosion behavior of the Zn-Cu alloy are thoroughly explored in this study. A model is developed using finite element analysis to investigate the impacts of flow rates and fluid-induced shear stress. The results reveal that the corrosion process of the Zn-Cu alloy is significantly accelerated by a higher flow rate, and a large fluid-induced shear stress caused by the boundary effect is found to promote corrosion. Furthermore, the empirical power function between the average flare rates in Hank’s solution and the corrosion rates of the Zn-Cu alloy is established by numerical simulation. The results provide insightful theoretical and experimental guidance to improve and evaluate the efficacy and lifespan of biomedical zinc-based alloy implants.
Open AccessEffects of Dynamic Flow Rates on the In Vitro Bio-Corrosion Behavior of Zn-Cu Alloy
In the complicated real physiological environment in vivo, body fluids and blood are constantly replenished and move dynamically, and therefore, the dynamic impacts of bodily fluids and blood need to be considered in the evaluation of biodegradable materials. However, little research has been conducted on the impact of dynamic flowing circumstances on the corrosion characteristics of zinc-based alloys, particularly at high flow rates. The effects of various flow rates on the bio-corrosion behavior of the Zn-Cu alloy are thoroughly explored in this study. A model is developed using finite element analysis to investigate the impacts of flow rates and fluid-induced shear stress. The results reveal that the corrosion process of the Zn-Cu alloy is significantly accelerated by a higher flow rate, and a large fluid-induced shear stress caused by the boundary effect is found to promote corrosion. Furthermore, the empirical power function between the average flare rates in Hank’s solution and the corrosion rates of the Zn-Cu alloy is established by numerical simulation. The results provide insightful theoretical and experimental guidance to improve and evaluate the efficacy and lifespan of biomedical zinc-based alloy implants.