Sophie Melicine
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sophie Melicine has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Georges Jourdi
Haematology Laboratory, Lariboisière University Hospital, Assistance Publique‐Hôpitaux de Paris (AP‐HP.Nord) Paris France
2 shared publications - Virginie Siguret
Haematology Laboratory, Lariboisière University Hospital, Assistance Publique‐Hôpitaux de Paris (AP‐HP.Nord) Paris France
2 shared publications - Alain Stepanian
Haematology Laboratory, CHU Montpellier, Univ Montpellier, CNRS, INSERM Montpellier France
1 shared publication - Antoine Mokhtarian
Service d'Hématologie Biologique Hôpital Lariboisière, APHP.Nord Paris France
1 shared publication - Bérangère S. Joly
Université Paris Cité, Sorbonne Université, Inserm UMRS_1138, Centre de Recherche des Cordeliers, Paris, France
1 shared publication C. Bon
PROBIOQUAL Lyon France
1 shared publication
Latest Publications
- Open Access
- 2 September 2026
- Published by Wiley in International Journal of Laboratory Hematology
Performance Assessment of Staclot‐LA Assay on Fully Automated Coagulation Analyser for Lupus Anticoagulant Testing Using Internal and External Quality Controls
Introduction: It is recommended to detect lupus anticoagulant (LA) using two phospholipid‐dependent clotting assays, including a LA‐sensitive activated partial‐thromboplastin‐time (aPTT). Among these reagents, Staclot‐LA assay is performed on a mixture of test and normal plasma with and without hexagonal phase phospholipids. However, its lack of validation on automated coagulation analyser is a major drawback. We aimed i/to assess the analytical performance of Staclot‐LA assay on automated system; ii/to compare inter‐laboratory agreement of Staclot‐LA performed on semi‐automated or fully automated analysers using two external‐quality‐assurance (EQA) programs data. Methods: We adapted the Staclot‐LA assay (Stago) set‐up on a STA‐R‐Max analyser and locally validated the manufacturer's recommended cut‐off for positive LA testing using samples from healthy volunteers. Reproducibility and accuracy were assessed using internal quality controls (IQC, Staclot‐LA1/LA2) over a five‐year period. Staclot‐LA results from EQA Probioqual and ECAT were compared between semi‐ and fully‐automated analysers. Results: Agreement of our LA results (positive or negative) was observed in 100% of IQC ( n = 130) and EQA ( n = 58) samples. Probioqual and ECAT interlaboratory Staclot‐LA results showed full agreement for 96.2% and 89.7% in semi‐automated system users vs 96.7% and 92.5% in automated system users. The system had no significant impact on the qualitative results (Probioqual p = 1.000; ECAT p = 0.5912), even though we observed increasing biases of the differences in clotting times, especially in LA positive samples on automated vs semi‐automated analysers. Conclusion: Staclot‐LA assay can be reliably performed on a fully automated system, thus paving the way for wider accessibility and widespread use.
- 2 September 2026
- Published by Wiley in International Journal of Laboratory Hematology
Open AccessPerformance Assessment of Staclot‐LA Assay on Fully Automated Coagulation Analyser for Lupus Anticoagulant Testing Using Internal and External Quality Controls
Introduction: It is recommended to detect lupus anticoagulant (LA) using two phospholipid‐dependent clotting assays, including a LA‐sensitive activated partial‐thromboplastin‐time (aPTT). Among these reagents, Staclot‐LA assay is performed on a mixture of test and normal plasma with and without hexagonal phase phospholipids. However, its lack of validation on automated coagulation analyser is a major drawback. We aimed i/to assess the analytical performance of Staclot‐LA assay on automated system; ii/to compare inter‐laboratory agreement of Staclot‐LA performed on semi‐automated or fully automated analysers using two external‐quality‐assurance (EQA) programs data. Methods: We adapted the Staclot‐LA assay (Stago) set‐up on a STA‐R‐Max analyser and locally validated the manufacturer's recommended cut‐off for positive LA testing using samples from healthy volunteers. Reproducibility and accuracy were assessed using internal quality controls (IQC, Staclot‐LA1/LA2) over a five‐year period. Staclot‐LA results from EQA Probioqual and ECAT were compared between semi‐ and fully‐automated analysers. Results: Agreement of our LA results (positive or negative) was observed in 100% of IQC ( n = 130) and EQA ( n = 58) samples. Probioqual and ECAT interlaboratory Staclot‐LA results showed full agreement for 96.2% and 89.7% in semi‐automated system users vs 96.7% and 92.5% in automated system users. The system had no significant impact on the qualitative results (Probioqual p = 1.000; ECAT p = 0.5912), even though we observed increasing biases of the differences in clotting times, especially in LA positive samples on automated vs semi‐automated analysers. Conclusion: Staclot‐LA assay can be reliably performed on a fully automated system, thus paving the way for wider accessibility and widespread use.
- Open Access
- 18 March 2025
- Published by Wiley in Clinical and Translational Science
- Vol. 18 (3) , e70164
Effect of Selective Serotonin Reuptake Inhibitors on Coagulation: Fact or Fiction?
Selective serotonin reuptake inhibitors (SSRIs) are commonly prescribed for depression and anxiety yet are associated with an increased bleeding risk. While this risk is mainly linked to the decrease in platelet serotonin content, thus abnormal platelet functions, some studies suggest an inherent effect of SSRIs on coagulation. Hence, we performed a literature review to provide an overview of the different studies assessing SSRI's effects on coagulation assays routinely used in clinical practice. A search of the PubMed database yielded 22 relevant studies. Results were inconsistent: While some studies showed minor changes in routine coagulation assays, namely, prothrombin time and activated partial thromboplastin time, the majority found no significant effects of SSRIs on coagulation tests. Then, we specifically investigated the impact of citalopram, a commonly prescribed SSRI, on the thrombin generation assay (TGA) allowing the detection of any potential procoagulant or anticoagulant effect. TGA was performed in platelet‐poor plasma from 14 healthy volunteers spiked with citalopram at therapeutic (0.1 and 0.5 μM) and supratherapeutic (50 μM) concentrations. TGA parameters were not significantly changed compared to the control condition regardless of the citalopram concentration. All in all, our findings failed to demonstrate any compromised coagulation function associated with SSRI therapy.
- 18 March 2025
- Published by Wiley in Clinical and Translational Science
- Vol. 18 (3) , e70164
Open AccessEffect of Selective Serotonin Reuptake Inhibitors on Coagulation: Fact or Fiction?
Selective serotonin reuptake inhibitors (SSRIs) are commonly prescribed for depression and anxiety yet are associated with an increased bleeding risk. While this risk is mainly linked to the decrease in platelet serotonin content, thus abnormal platelet functions, some studies suggest an inherent effect of SSRIs on coagulation. Hence, we performed a literature review to provide an overview of the different studies assessing SSRI's effects on coagulation assays routinely used in clinical practice. A search of the PubMed database yielded 22 relevant studies. Results were inconsistent: While some studies showed minor changes in routine coagulation assays, namely, prothrombin time and activated partial thromboplastin time, the majority found no significant effects of SSRIs on coagulation tests. Then, we specifically investigated the impact of citalopram, a commonly prescribed SSRI, on the thrombin generation assay (TGA) allowing the detection of any potential procoagulant or anticoagulant effect. TGA was performed in platelet‐poor plasma from 14 healthy volunteers spiked with citalopram at therapeutic (0.1 and 0.5 μM) and supratherapeutic (50 μM) concentrations. TGA parameters were not significantly changed compared to the control condition regardless of the citalopram concentration. All in all, our findings failed to demonstrate any compromised coagulation function associated with SSRI therapy.
- 27 May 2024
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 46 (5) , 953-962
DOAC‐Remove to counteract the interference of anti‐Xa oral anticoagulants on the monitoring of heparin
Introduction: The monitoring of unfractionated heparin (UFH) by anti‐factor Xa activity (AXA) is commonly used to ensure effective anticoagulation and prevent bleeding risk. However, in patients previously treated with an anti‐Xa direct oral anticoagulant (DOAC) switching to UFH therapy, there is a risk of interference that may lead to inappropriate anticoagulation. The first objective of this study was to validate DOAC‐Remove to remove DOAC for measuring UFH specific AXA. The second objective was to assess the length of DOAC interference on UFH monitoring and to identify potential predictive factors. Materials and Methods: This monocentric retrospective study included all patients admitted from April 2019 to April 2021 previously treated with anti‐Xa DOAC, and for whom an interference on UFH monitoring was suspected. Interference was defined as a difference in the AXA measured before and after using DOAC‐Remove >2.8‐fold standard deviation of the method. Results: Removal with DOAC‐Remove was specific of DOAC (apixaban n = 42, rivaroxaban n = 41, UFH n = 20) and sufficient to avoid interference on UFH AXA measurement. The exact interference length was 6.0 days [IQR 3.0–11.0] for apixaban ( n = 26) and 4.5 days [IQR 2.0–5.8] for rivaroxaban ( n = 20). Among the 89 patients sorted based on an interference length ≤ or >3 days, 74 (83.1%) presented an interference greater than 3 days. Correlations were observed with age for apixaban and creatinine for rivaroxaban. Conclusions: Our results suggest that DOAC‐Remove could be of high interest in patients receiving UFH previously treated with an anti‐Xa DOAC even if DOAC was stopped for more than 3 days.
- 27 May 2024
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 46 (5) , 953-962
DOAC‐Remove to counteract the interference of anti‐Xa oral anticoagulants on the monitoring of heparin
Introduction: The monitoring of unfractionated heparin (UFH) by anti‐factor Xa activity (AXA) is commonly used to ensure effective anticoagulation and prevent bleeding risk. However, in patients previously treated with an anti‐Xa direct oral anticoagulant (DOAC) switching to UFH therapy, there is a risk of interference that may lead to inappropriate anticoagulation. The first objective of this study was to validate DOAC‐Remove to remove DOAC for measuring UFH specific AXA. The second objective was to assess the length of DOAC interference on UFH monitoring and to identify potential predictive factors. Materials and Methods: This monocentric retrospective study included all patients admitted from April 2019 to April 2021 previously treated with anti‐Xa DOAC, and for whom an interference on UFH monitoring was suspected. Interference was defined as a difference in the AXA measured before and after using DOAC‐Remove >2.8‐fold standard deviation of the method. Results: Removal with DOAC‐Remove was specific of DOAC (apixaban n = 42, rivaroxaban n = 41, UFH n = 20) and sufficient to avoid interference on UFH AXA measurement. The exact interference length was 6.0 days [IQR 3.0–11.0] for apixaban ( n = 26) and 4.5 days [IQR 2.0–5.8] for rivaroxaban ( n = 20). Among the 89 patients sorted based on an interference length ≤ or >3 days, 74 (83.1%) presented an interference greater than 3 days. Correlations were observed with age for apixaban and creatinine for rivaroxaban. Conclusions: Our results suggest that DOAC‐Remove could be of high interest in patients receiving UFH previously treated with an anti‐Xa DOAC even if DOAC was stopped for more than 3 days.