Barbara Rynkus
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Barbara Rynkus has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Ada Orłowska
Department of Biomaterials and Medical Device Engineering, Faculty of Biomedical Engineering, Silesian University of Technology, Roosevelta 40, 41-800 Zabrze, Poland
5 shared publications - Karolina Wilk
Department of Biomaterials and Medical Devices Engineering, Faculty of Biomedical Engineering, Silesian University of Technology, 41-800 Zabrze, Poland
5 shared publications - Karolina Szawiraacz
Institute of Metallurgy and Materials Science, Polish Academy of Sciences, Reymonta 25, 30-059 Kraków, Poland
4 shared publications - Anna Taratuta
Department of Biomaterials and Medical Devices Engineering, Faculty of Biomedical Engineering, Silesian University of Technology, Roosevelta 40 Street, 41-800 Zabrze, Poland
3 shared publications - Maciej Sowa
Faculty of Chemistry, Silesian University of Technology, Gliwice, Poland
3 shared publications Roman Major
3 shared publications
Latest Publications
- Open Access
- 22 May 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (11) , 4031
Breast Implants: Biomaterials, Surfaces, Biocompatibility—A Biomedical Engineering Perspective
Breast implants are among the most frequently used long-term implantable medical devices in aesthetic and reconstructive surgery. In addition to correcting anatomical deficits, they have significant psychosocial effects, influencing body image, self-esteem, and quality of life, particularly in patients undergoing postmastectomy reconstruction. This review provides a comprehensive overview of the historical development, biological interactions, material characteristics, and clinical outcomes of breast implants. Early reconstructive attempts using foreign materials and injectable substances were associated with severe complications, underscoring the need for safer technologies. The introduction of silicone gel implants in the 1960s marked a pivotal advancement, followed by the development of saline-filled devices and highly cohesive silicone gels with enhanced mechanical stability. Key surgical considerations, including incision type and implant placement plane (subglandular, submuscular, dual-plane, and subfascial), are discussed in relation to aesthetic outcomes and complication risk. Emphasis is placed on the implant–tissue interface and the foreign body response (FBR), a process involving protein adsorption, immune cell activation, fibrous capsule formation, and potential chronic inflammation. Persistent inflammatory stimulation, often associated with bacterial biofilm formation, contributes to capsular contracture, the most common long-term complication. Additional adverse events include implant rupture, silicone gel bleed, granulomatous reactions, infection, hematoma, implant malposition, and rare but clinically significant conditions such as breast implant-associated anaplastic large cell lymphoma (BIA-ALCL). The review also summarizes implant classification according to construction, filling material, shape, and surface topography, highlighting the influence of surface characteristics on host response and clinical outcomes. Advances in biomaterials, cohesive gel formulations, and surface engineering aim to enhance biocompatibility and long-term safety, supported by standardized mechanical and biological testing protocols.
- 22 May 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (11) , 4031
Open AccessBreast Implants: Biomaterials, Surfaces, Biocompatibility—A Biomedical Engineering Perspective
Breast implants are among the most frequently used long-term implantable medical devices in aesthetic and reconstructive surgery. In addition to correcting anatomical deficits, they have significant psychosocial effects, influencing body image, self-esteem, and quality of life, particularly in patients undergoing postmastectomy reconstruction. This review provides a comprehensive overview of the historical development, biological interactions, material characteristics, and clinical outcomes of breast implants. Early reconstructive attempts using foreign materials and injectable substances were associated with severe complications, underscoring the need for safer technologies. The introduction of silicone gel implants in the 1960s marked a pivotal advancement, followed by the development of saline-filled devices and highly cohesive silicone gels with enhanced mechanical stability. Key surgical considerations, including incision type and implant placement plane (subglandular, submuscular, dual-plane, and subfascial), are discussed in relation to aesthetic outcomes and complication risk. Emphasis is placed on the implant–tissue interface and the foreign body response (FBR), a process involving protein adsorption, immune cell activation, fibrous capsule formation, and potential chronic inflammation. Persistent inflammatory stimulation, often associated with bacterial biofilm formation, contributes to capsular contracture, the most common long-term complication. Additional adverse events include implant rupture, silicone gel bleed, granulomatous reactions, infection, hematoma, implant malposition, and rare but clinically significant conditions such as breast implant-associated anaplastic large cell lymphoma (BIA-ALCL). The review also summarizes implant classification according to construction, filling material, shape, and surface topography, highlighting the influence of surface characteristics on host response and clinical outcomes. Advances in biomaterials, cohesive gel formulations, and surface engineering aim to enhance biocompatibility and long-term safety, supported by standardized mechanical and biological testing protocols.
- Open Access
- 21 May 2026
- Published by Elsevier in Materials & Design
- Vol. 267
Electrophoretic deposition of SiO2 coatings on nitinol: The effect of suspension pH on tailoring film properties
- 21 May 2026
- Published by Elsevier in Materials & Design
- Vol. 267
Open AccessElectrophoretic deposition of SiO2 coatings on nitinol: The effect of suspension pH on tailoring film properties
- Open Access
- 5 May 2026
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 18 (19) , 27264-27280
Surface Engineering of NiTi via Ta 2 O 5 ALD: Stability Assessment of Barrier Properties against Exposure to Simulated Physiological Solution
Tantalum pentoxide (Ta2O5) coatings deposited via atomic layer deposition (ALD) have emerged as promising protective barriers for NiTi shape memory alloys in biomedical applications. This study investigates the influence of 800 ALD cycles on the structural, tribological, and electrochemical stability of NiTi substrates during long-term exposure to physiological environments. A conformal, amorphous Ta2O5 layer with a thickness of ∼65 nm was achieved, effectively sealing the substrate topography. Our findings reveal that while the coating initially maintains a hydrophilic character, prolonged incubation (60 days) in PBS solution triggers a transition to a hydrophobic state of 104 ± 3°, driven by the accumulation of Ca- and P-mineralized deposits. Tribological assessments demonstrate that the Ta2O5 overlayer enhances wear resistance and load-bearing capacity, despite localized microdelamination observed postexposure. Most notably, the ALD coating acts as a robust diffusion barrier, reducing the corrosion current density to 7.60 × 10–8 A/cm2 and maintaining a high polarization resistance even after 60 days of incubation. These results highlight the efficacy of Ta2O5 overlayers in providing long-term biostability and corrosion protection for NiTi-based implants in demanding physiological conditions.
- 5 May 2026
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 18 (19) , 27264-27280
Open AccessSurface Engineering of NiTi via Ta 2 O 5 ALD: Stability Assessment of Barrier Properties against Exposure to Simulated Physiological Solution
Tantalum pentoxide (Ta2O5) coatings deposited via atomic layer deposition (ALD) have emerged as promising protective barriers for NiTi shape memory alloys in biomedical applications. This study investigates the influence of 800 ALD cycles on the structural, tribological, and electrochemical stability of NiTi substrates during long-term exposure to physiological environments. A conformal, amorphous Ta2O5 layer with a thickness of ∼65 nm was achieved, effectively sealing the substrate topography. Our findings reveal that while the coating initially maintains a hydrophilic character, prolonged incubation (60 days) in PBS solution triggers a transition to a hydrophobic state of 104 ± 3°, driven by the accumulation of Ca- and P-mineralized deposits. Tribological assessments demonstrate that the Ta2O5 overlayer enhances wear resistance and load-bearing capacity, despite localized microdelamination observed postexposure. Most notably, the ALD coating acts as a robust diffusion barrier, reducing the corrosion current density to 7.60 × 10–8 A/cm2 and maintaining a high polarization resistance even after 60 days of incubation. These results highlight the efficacy of Ta2O5 overlayers in providing long-term biostability and corrosion protection for NiTi-based implants in demanding physiological conditions.
- Open Access
Optimization of Hybrid PEO/P(L/G/TMC) Coatings on WE43B Magnesium Alloy: Effect of Polymer Layer Number on Surface Properties
Magnesium alloys are promising materials for orthopedic applications due to their biodegradability and mechanical properties compatible with bone. However, their rapid degradation in physiological environments limits clinical use. In this study, WE43B magnesium alloy was coated with a PEO layer followed by a P(L/G/TMC) polymer applied via ultrasonic spraying. The influence of polymer layer number (10, 20, 30) on coating properties was systematically investigated. Scanning electron microscopy (SEM) analysis revealed an approximately fourfold reduction in porosity after polymer deposition, with progressive pore filling at higher layer numbers, while Fourier transform infrared spectroscopy (FT-IR) mapping indicated uniform polymer coverage. Compared to PEO alone, polymer-modified samples exhibited an approximately 7-fold increase in water contact angle, a ~50% reduction in surface roughness, and improved adhesion. Degradation-related analyses, including ion release, post-immersion SEM, and scanning acoustic microscopy (SAM), indicated that increasing polymer thickness effectively limited degradation processes. Ion release decreased by ~40–50% for the 30-layer coating compared to PEO, with the most pronounced reduction observed between the uncoated PEO and polymer-modified samples. These results demonstrate that the number of polymer layers plays a key role in controlling the barrier properties and stability of hybrid PEO/polymer coatings under simulated physiological conditions.
Open AccessOptimization of Hybrid PEO/P(L/G/TMC) Coatings on WE43B Magnesium Alloy: Effect of Polymer Layer Number on Surface Properties
Magnesium alloys are promising materials for orthopedic applications due to their biodegradability and mechanical properties compatible with bone. However, their rapid degradation in physiological environments limits clinical use. In this study, WE43B magnesium alloy was coated with a PEO layer followed by a P(L/G/TMC) polymer applied via ultrasonic spraying. The influence of polymer layer number (10, 20, 30) on coating properties was systematically investigated. Scanning electron microscopy (SEM) analysis revealed an approximately fourfold reduction in porosity after polymer deposition, with progressive pore filling at higher layer numbers, while Fourier transform infrared spectroscopy (FT-IR) mapping indicated uniform polymer coverage. Compared to PEO alone, polymer-modified samples exhibited an approximately 7-fold increase in water contact angle, a ~50% reduction in surface roughness, and improved adhesion. Degradation-related analyses, including ion release, post-immersion SEM, and scanning acoustic microscopy (SAM), indicated that increasing polymer thickness effectively limited degradation processes. Ion release decreased by ~40–50% for the 30-layer coating compared to PEO, with the most pronounced reduction observed between the uncoated PEO and polymer-modified samples. These results demonstrate that the number of polymer layers plays a key role in controlling the barrier properties and stability of hybrid PEO/polymer coatings under simulated physiological conditions.
- Open Access
- 28 October 2025
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 39, 5637-5651
EPD-derived SiO2 coatings on NiTi alloys: Biocompatibility and corrosion challenges in cardiovascular applications
- 28 October 2025
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 39, 5637-5651
Open AccessEPD-derived SiO2 coatings on NiTi alloys: Biocompatibility and corrosion challenges in cardiovascular applications
- Open Access
- 1 July 2025
- Published by KEAI Publishing in Journal of Magnesium and Alloys
- Vol. 13 (7) , 3398-3417
Bioactive Ca-P coatings on WE43 alloy via soft sparking PEO: Structure, electrochemical performance and cytotoxicity studies
- 1 July 2025
- Published by KEAI Publishing in Journal of Magnesium and Alloys
- Vol. 13 (7) , 3398-3417
Open AccessBioactive Ca-P coatings on WE43 alloy via soft sparking PEO: Structure, electrochemical performance and cytotoxicity studies
- 29 May 2024
- Published by Wiley in Materialwissenschaft und Werkstofftechnik
- Vol. 55 (5) , 622-627
Properties of silicon dioxide coatings obtained by nano physical vapor deposition (PVD) method on the titanium 13‐niobium 13‐zirconium alloy
Surface modification techniques play an important role in adjusting the physicochemical properties of titanium and its alloys. To reduce the penetration of alloying element ions into the body, various types of oxide coatings are used to protect it from the corrosive environment. Another important issue related to the surface layer requirement is ensuring an appropriate set of mechanical properties. Accordingly, in this study, the mechanical and electrochemical properties of the silicon dioxide layers formed by the deposition of nano physical vapor deposition on the surface of titanium and titanium 13‐niobium 13‐zirconium alloy samples were investigated. To evaluate the mechanical properties of the layers produced by this method, hardness tests were carried out, as well as tests on the adhesion of these layers to the metal substrate. On the other hand, electrochemical properties were studied using potentiodynamic measurements to assess the resistance to pitting corrosion, followed by impedance measurements to interpret the processes and phenomena occurring at the silicon dioxide layer/electrolyte interface. The data obtained showed different mechanical and electrochemical properties of the silicon dioxide layers generated with varying process parameters.
- 29 May 2024
- Published by Wiley in Materialwissenschaft und Werkstofftechnik
- Vol. 55 (5) , 622-627
Properties of silicon dioxide coatings obtained by nano physical vapor deposition (PVD) method on the titanium 13‐niobium 13‐zirconium alloy
Surface modification techniques play an important role in adjusting the physicochemical properties of titanium and its alloys. To reduce the penetration of alloying element ions into the body, various types of oxide coatings are used to protect it from the corrosive environment. Another important issue related to the surface layer requirement is ensuring an appropriate set of mechanical properties. Accordingly, in this study, the mechanical and electrochemical properties of the silicon dioxide layers formed by the deposition of nano physical vapor deposition on the surface of titanium and titanium 13‐niobium 13‐zirconium alloy samples were investigated. To evaluate the mechanical properties of the layers produced by this method, hardness tests were carried out, as well as tests on the adhesion of these layers to the metal substrate. On the other hand, electrochemical properties were studied using potentiodynamic measurements to assess the resistance to pitting corrosion, followed by impedance measurements to interpret the processes and phenomena occurring at the silicon dioxide layer/electrolyte interface. The data obtained showed different mechanical and electrochemical properties of the silicon dioxide layers generated with varying process parameters.
- 16 February 2024
- Published by Springer Nature
- p. 160-167
Study of the Physical and Electrochemical Properties of Surface Modified Co Alloy Intended for Urology
- 16 February 2024
- Published by Springer Nature
- p. 160-167
Study of the Physical and Electrochemical Properties of Surface Modified Co Alloy Intended for Urology