MPMatthew S. Purlee

Matthew S. Purlee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Matthew S. Purlee has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Single-Center Experience With En-Bloc Combined Heart+Liver Transplantation: Analysis of Eight Cases, Including Two Heart+Liver+Kidney Transplants

    by Matthew S. Purlee, Thiago Beduschi, Jeffrey Phillip Jacobs, Werviston De Faria, Giles J. Peek, Ahmet Bilgili, Yuriy Stukov, Mark Steven Bleiweis

    Objectives: Review our clinical experience with eight patients at the University of Florida undergoing En-bloc combined heart+liver transplantation (ECH + LTX). Methods: Continuous variables are reported as median (interquartile range = IQR) and categorical variables are reported as N (%). Results: Eight patients underwent ECH + LTX between August 2020 and May 2023 at the University of Florida, with triple heart+liver+kidney transplantation performed in 2/8 = 25%. Median age at ECH + LTX was 47.34 years (IQR = 33.66-53.37), and all eight patients were >18 years of age. Six out of eight patients (75%) had congenital heart disease (CHD): one had biventricular CHD and five had functionally univentricular circulation and Fontan failure. Two out of eight patients (25%) had structurally normal hearts and acquired heart disease: one patient with hemochromatosis and combined cardiac and hepatic failure with nonischemic restrictive cardiomyopathy and one patient with nonischemic cardiomyopathy and alcoholic cirrhosis. Median wait list time was 93 days (IQR = 27.50-176.25). Three patients (3/8 = 37.5%) were supported with an intra-aortic balloon pump prior to ECH + LTX, and two of these three patients were subsequently also supported with extracorporeal membrane oxygenation secondary to progressive decompensation prior to ECH + LTX. Median hospital length of stay was 147 days. Median posttransplant length of stay was of 29 days. Seven of eight patients survived ECH + LTX and are alive today. One patient died two days after ECH + LTX. Mean length of follow-up after ECH + LTX of seven surviving patients (years) is 3.60 ± 0.38 (median = 3.79, IQR = 3.05-4.38, range = 1.91-4.64). Conclusion: En-bloc heart-liver transplantation is an effective treatment option for patients with combined heart and liver failure.

  • Analysis of 112 Patients With Congenital Heart Disease Undergoing Cardiac Transplantation: Impact of Pretransplant Ventricular Assist Device

    by Mark Steven Bleiweis, Dipankar Gupta, Frederick J. Fricker, Joseph Philip, Giles J. Peek, Yuriy Stukov, John-Anthony Coppola, Omar M. Sharaf, Matthew S. Purlee, Colton D. Brown, et al.

    Background: We reviewed our management strategy and outcome data for all 112 patients with congenital heart disease (CHD) who underwent cardiac transplantation at University of Florida from January 2011, to January 2022, and evaluated the impact of a pretransplant ventricular assist device (VAD). Methods: Continuous variables are presented as mean (SD); median [interquartile range] (range); categorical variables are presented as N (%). Univariable associations with long-term survival were assessed with Cox proportional hazards models. The impact of pretransplant VAD on survival was estimated with multivariable models. Results: Pretransplant VAD was present in 24 of 112 patients who underwent cardiac transplantation (21.4%). Patients with a VAD were younger (years): 3.0 (3.8); 1 [0.5,6] (0.1,14) versus 12.9 (14.9); 9 [0.6,19] (0.1,58), P  = .008. More patients with a VAD had prior cardiac operations: 24 of 24 (100%) versus 71 of 88 (80.7%), P  = .021 and were more likely to receive an ABO-incompatible transplant: 6 of 24 (25%) versus 7 of 88 (8%), P  = .032. Univariable associations with long-term mortality include: Number of prior cardiac surgeries-hazard ratio (HR) multiplies by 1.2 for each additional surgery (1.02-1.44), P  = .029. Pretransplant renal dysfunction - HR = 2.8 (1.21-6.68), P  = .017. Cardiopulmonary bypass (CPB) time at transplant: HR multiplies by 1.1 for each 10 min increase above the minimum CPB time in this series (1.03-1.19), P  = .008. In multivariable analysis, pretransplant VAD does not impact survival when controlling for each one of the factors shown in univariable analysis to be associated with long-term survival. Kaplan-Meier five-year survival (95% confidence interval) is 77.4% (68.4%-87.5%) for all patients; 76.5% (66.7%-87.9%) without pretransplant VAD and 84.3% (69.3%-99.9%) with pretransplant VAD ( P  = .436). Conclusion: Our single-institution analysis of 112 patients with CHD undergoing cardiac transplantation over 11.25 years reveals similar survival in patients with (n = 24) and without (n = 88) pretransplant VAD. The presence of a pretransplant VAD is not a risk factor for survival after transplantation in patients with CHD.


  • Quantitative methods to improve bivalirudin dosing in pediatric cardiac ICU patients

    by Lindsey Brinkley, Zasha Vazquez-Colon, Aashay Patel, Matthew S Purlee, Terry Vasilopoulos, Mark S Bleiweis, Jeffrey P Jacobs, Giles J Peek, Helen Moore

    Background: A gap in knowledge exists related to optimal bivalirudin dosing in children. The purpose of our analysis is to use quantitative methods and baseline data to quickly predict the optimal therapeutic bivalirudin dose for children. Methods: We developed an internal database of pediatric patients on ECMO or VAD, including baseline patient information, bivalirudin doses, and partial thromboplastin time (PTT) measurements throughout the treatment period. We fit an analysis of covariance (ANCOVA) model to the baseline data to determine the best predictors of therapeutic bivalirudin dose. We used five-fold cross-validation to ensure the model was not overfitting to any specific data subset. Results: The most notable variables that were statistically significant ( p < .05) were: the primary use of bivalirudin for heart failure prophylaxis, no complications before bivalirudin administration, other reasons for bivalirudin use, other race (including Asian, pacific islander, and native American), Hispanic or Latinx ethnicity, primary diagnosis of heart failure, and primary diagnosis of myocarditis. To compare our model-predicted dose and the actual starting dose administered to the patients, we looked at how far off each of those was from the therapeutic dose. The mean of absolute differences was 0.28 mg/kg/hr for the administered starting dose and 0.23 mg/kg/hr for the model-predicted dose; therefore, the model results in an improvement of 18% in the difference from the therapeutic dose. Conclusion: Our model provides an initial framework for determining a starting bivalirudin dose that takes into account patient demographic information and baseline admission data.


  • What is the weakest point of a secured aortic cannula in central extracorporeal membrane oxygenation?

    by Kayla V. Lucas, Yuriy Stukov, Matthew S. Purlee, Tatiana Delaleu, Omar M. Sharaf, Mark S. Bleiweis, Jeffrey Phillip Jacobs, Giles J. Peek

    Purpose: The purpose of this study was to compare techniques for securing the aortic extracorporeal membrane oxygenation (ECMO) cannula, using in vitro models. Methods: Two models were studied: a tissue model using porcine aortas and a stand model replacing the aorta with a metal stand to study the system independent of the tissue. Interventions in each model were divided into three experimental groups: Group 1 (3-0 Prolene® + 20-French Medtronic Arterial Cannula EOPA™), Group 2 (4-0 Prolene® + 16-French Medtronic Arterial Cannula DLP Pediatric), and Group 3 (5-0 Prolene® + 8-French Medtronic Arterial Cannula DLP Pediatric). In separate experiments, both gradual and rapid forces were applied to the cannulas, starting with 9.8 Newtons and increasing exponentially if the cannula remained secured. Additionally, the method of securing the tourniquet and the number of ties securing the tourniquet to the cannula were evaluated. Results: In the tissue model, even with a minimum force of 9.8 Newtons, the suture pulled through the aortic tissue, leaving sutures and ties intact. In the stand model, two purse-string sutures secured by two ligaclips held the cannula reliably and withstood higher total force. Dislodgement was prevented at forces close to 60 Newtons with only two hemostatic clips included in cannulation. Conclusions: The weakest part of the aortic ECMO cannulation system using in vitro experiments was the tissue. Assuming that these experiments translate in vivo, it is therefore critical to prevent any pull on the cannulas by securing ECMO cannulas and ECMO tubing to both the patient and the patient’s bed. Sutures with a larger diameter withstand more force. Two medium hemostatic clips can secure Prolene® sutures within snares as safely as a mosquito hemostat. Two polypropylene purse-string sutures secured by two hemostatic clips were most reliable at greater forces. The rationale for publishing our experiments in this manuscript is to (1) communicate our quantification of possible contributing factors to this rare and likely catastrophic complication of unintended decannulation, (2) increase awareness about this potential complication, and (3) increase vigilance to assure prevention of this dreaded complication.