Manuel Jerez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Manuel Jerez has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Alejandro Carballar
Departamento de Ingeniería Electrónica -E.T.S. de Ingeniería -Universidad de Sevilla
4 shared publications- Alejandro Carballar
Electronic Engineering Department, Universidad de Sevilla (E.T.S. de Ingeniería), C/Camino de los Descubrimientos s/n, 41092 Sevilla, Spain
2 shared publications Joaquín Granado
Departamento de Ingeniería Electrónica -E.T.S. de Ingeniería -Universidad de Sevilla
2 shared publicationsJosé González-Aguilar
High Temperature Processes Unit, IMDEA Energy, Av. Ramón de La Sagra, 3, 28935 Móstoles, Madrid, Spain
2 shared publicationsRicardo Conceição
High Temperature Processes Unit, IMDEA Energy, Av. Ramón de La Sagra, 3, 28935 Móstoles, Madrid, Spain
2 shared publications- Joaquin Granado
Electronic Engineering Department, Universidad de Sevilla (E.T.S. de Ingeniería), C/Camino de los Descubrimientos s/n, 41092 Sevilla, Spain
1 shared publication
Latest Publications
- Open Access
- 23 October 2025
- Published by TIB Open Publishing in SolarPACES Conference Proceedings
- Vol. 3
Optical Fiber as Solar Radiation Collector for Radiometric Measurements
The feasibility of using optical fibers as solar radiation collectors in radiometric measurement devices and instruments is discussed, taking into account the various characteristics of the fibers that affect the measurements, with a special focus on numerical aperture. The discussion is supported by various results using the fiber to measure direct normal irradiance.
- 23 October 2025
- Published by TIB Open Publishing in SolarPACES Conference Proceedings
- Vol. 3
Open AccessOptical Fiber as Solar Radiation Collector for Radiometric Measurements
The feasibility of using optical fibers as solar radiation collectors in radiometric measurement devices and instruments is discussed, taking into account the various characteristics of the fibers that affect the measurements, with a special focus on numerical aperture. The discussion is supported by various results using the fiber to measure direct normal irradiance.
- Open Access
Optical Fiber Performance for High Solar Flux Measurements in Concentrating Solar Power Applications
Extreme operating conditions in solar receivers of concentrated solar thermal power plants, such as high temperatures, intense irradiance, and thermal cycling, pose significant challenges for conventional sensors. Optical fibers offer a promising alternative for flux measurement in such environments, but their long-term performance and degradation mechanisms require detailed investigation and characterization. This work presents a proof of concept for high solar flux measurement by using optical fibers as photon-capturing elements and showcases the behavior and damage that these optical fibers undergo when exposed to relevant conditions, including temperatures over 600 °C and flux levels exceeding 400 kW/m2. Three fiber configurations, including polyimide and gold-coated fibers, were tested at a high-flux solar simulator and analyzed via scanning electron microscopy to assess structural integrity and material degradation. Results reveal significant coating deterioration, fiber retraction, and thermal-induced stress effects, which impact measurement reliability. These findings provide essential insights for improving the durability and accuracy of optical fiber-based sensing technologies in concentrating solar energy.
Open AccessOptical Fiber Performance for High Solar Flux Measurements in Concentrating Solar Power Applications
Extreme operating conditions in solar receivers of concentrated solar thermal power plants, such as high temperatures, intense irradiance, and thermal cycling, pose significant challenges for conventional sensors. Optical fibers offer a promising alternative for flux measurement in such environments, but their long-term performance and degradation mechanisms require detailed investigation and characterization. This work presents a proof of concept for high solar flux measurement by using optical fibers as photon-capturing elements and showcases the behavior and damage that these optical fibers undergo when exposed to relevant conditions, including temperatures over 600 °C and flux levels exceeding 400 kW/m2. Three fiber configurations, including polyimide and gold-coated fibers, were tested at a high-flux solar simulator and analyzed via scanning electron microscopy to assess structural integrity and material degradation. Results reveal significant coating deterioration, fiber retraction, and thermal-induced stress effects, which impact measurement reliability. These findings provide essential insights for improving the durability and accuracy of optical fiber-based sensing technologies in concentrating solar energy.
- 1 January 2025
- Published by Optica Publishing Group
- p. JM4A.17
Concentrated Solar Flux Measurement in a High Flux Solar Simulator Using an Optical Fiber Based Radiometer
A novel device for measuring concentrated solar fluxes using high-temperature optical fibers and photodiode-based radiometers is evaluated using a high-flux solar simulator based on Xenon arc lamps, showcasing promising results.
- 1 January 2025
- Published by Optica Publishing Group
- p. JM4A.17
Concentrated Solar Flux Measurement in a High Flux Solar Simulator Using an Optical Fiber Based Radiometer
A novel device for measuring concentrated solar fluxes using high-temperature optical fibers and photodiode-based radiometers is evaluated using a high-flux solar simulator based on Xenon arc lamps, showcasing promising results.
- 1 January 2025
- Published by Optica Publishing Group
- p. SM3E.2
Evaluating Fiber Bragg Grating Technologies for High Temperature Sensing in Concentrated Solar Power Plants
Femtosecond-inscribed versus regenerated FBGs are compared for temperature sensing in Concentrated Solar Power applications. Experiments up to 1000°C demonstrate fs-FBGs’ superior performance, requiring recalibration for optimal CSP integration.
- 1 January 2025
- Published by Optica Publishing Group
- p. SM3E.2
Evaluating Fiber Bragg Grating Technologies for High Temperature Sensing in Concentrated Solar Power Plants
Femtosecond-inscribed versus regenerated FBGs are compared for temperature sensing in Concentrated Solar Power applications. Experiments up to 1000°C demonstrate fs-FBGs’ superior performance, requiring recalibration for optimal CSP integration.
- 1 January 2025
- Published by Optica Publishing Group
- p. SW1E.3
Damage in Optical Fiber-based Sensors in Extreme Environments For High Flux Solar Measurements
Physical damage in optical fibers when acting as irradiance probes in a high-flux solar simulator is analyzed through SEM. Coating degradation and relative displacement of the fiber due to local intense heat fluxes are observed.
- 1 January 2025
- Published by Optica Publishing Group
- p. SW1E.3
Damage in Optical Fiber-based Sensors in Extreme Environments For High Flux Solar Measurements
Physical damage in optical fibers when acting as irradiance probes in a high-flux solar simulator is analyzed through SEM. Coating degradation and relative displacement of the fiber due to local intense heat fluxes are observed.
- Open Access
Measuring DNI with a New Radiometer Based on an Optical Fiber and Photodiode
A new cost-effective radiometer has been designed, built, and tested to measure direct normal solar irradiance (DNI). The proposed instrument for solar irradiance measurement is based on an optical fiber as the light beam collector, a semiconductor photodiode to measure the optical power, and a calibration algorithm to convert the optical power into solar irradiance. The proposed radiometer offers the advantage of separating the measurement point, where the optical fiber collects the solar irradiation, from the place where the optical power is measured. A calibration factor is mandatory because the semiconductor photodiode is only spectrally responsive to a limited part of the spectral irradiance. Experimental tests have been conducted under different conditions to evaluate the performance of the proposed device. The measurements confirm that the proposed instrument performs similarly to the expensive high-accuracy pyrheliometer used as a reference.
Open AccessMeasuring DNI with a New Radiometer Based on an Optical Fiber and Photodiode
A new cost-effective radiometer has been designed, built, and tested to measure direct normal solar irradiance (DNI). The proposed instrument for solar irradiance measurement is based on an optical fiber as the light beam collector, a semiconductor photodiode to measure the optical power, and a calibration algorithm to convert the optical power into solar irradiance. The proposed radiometer offers the advantage of separating the measurement point, where the optical fiber collects the solar irradiation, from the place where the optical power is measured. A calibration factor is mandatory because the semiconductor photodiode is only spectrally responsive to a limited part of the spectral irradiance. Experimental tests have been conducted under different conditions to evaluate the performance of the proposed device. The measurements confirm that the proposed instrument performs similarly to the expensive high-accuracy pyrheliometer used as a reference.