KOKyle P. O’sullivan

Kyle P. O’sullivan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kyle P. O’sullivan has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Coupled Eulerian–Lagrangian model prediction of neural tissue strain during microelectrode insertion

    by K P O’sUllivan, B Coats

    Objective. Implanted neural microelectrodes are an important tool for recording from and stimulating the cerebral cortex. The performance of chronically implanted devices, however, is often hindered by the development of a reactive tissue response. Previous computational models have investigated brain strain from micromotions of neural electrodes after they have been inserted, to investigate design parameters that might minimize triggers to the reactive tissue response. However, these models ignore tissue damage created during device insertion, an important contributing factor to the severity of inflammation. The objective of this study was to evaluate the effect of electrode geometry, insertion speed, and surface friction on brain tissue strain during insertion. Approach. Using a coupled Eulerian–Lagrangian approach, we developed a 3D finite element model (FEM) that simulates the dynamic insertion of a neural microelectrode in brain tissue. Geometry was varied to investigate tip bluntness, cross-sectional shape, and shank thickness. Insertion velocities were varied from 1 to 8 m s−1. Friction was varied from frictionless to 0.4. Tissue strain and potential microvasculature hemorrhage radius were evaluated for brain regions along the electrode shank and near its tip. Main results. Sharper tips resulted in higher mean max principal strains near the tip except for the bluntest tip on the square cross-section electrode, which exhibited high compressive strain values due to stress concentrations at the corners. The potential vascular damage radius around the electrode was primarily a function of the shank diameter, with smaller shank diameters resulting in smaller distributions of radial strain around the electrode. However, the square shank interaction with the tip taper length caused unique strain distributions that increased the damage radius in some cases. Faster insertion velocities created more strain near the tip but less strain along the shank. Increased friction between the brain and electrode created more strain near the electrode tip and along the shank, but frictionless interactions resulted in increased tearing of brain tissue near the tip. Significance. These results demonstrate the first dynamic FEM study of neural electrode insertion, identifying design factors that can reduce tissue strain and potentially mitigate initial reactive tissue responses due to traumatic microelectrode array insertion.


  • Open Access

    In Vivo and In Vitro Electrochemical Impedance Spectroscopy of Acute and Chronic Intracranial Electrodes

    by Kyle P. O’sullivan, Brian J. Philip, Jonathan L. Baker, John D. Rolston, Mark E. Orazem, Kevin J. Otto, Christopher R. Butson

    Invasive intracranial electrodes are used in both clinical and research applications for recording and stimulation of brain tissue, providing essential data in acute and chronic contexts. The impedance characteristics of the electrode–tissue interface (ETI) evolve over time and can change dramatically relative to pre-implantation baseline. Understanding how ETI properties contribute to the recording and stimulation characteristics of an electrode can provide valuable insights for users who often do not have access to complex impedance characterizations of their devices. In contrast to the typical method of characterizing electrical impedance at a single frequency, we demonstrate a method for using electrochemical impedance spectroscopy (EIS) to investigate complex characteristics of the ETI of several commonly used acute and chronic electrodes. We also describe precise modeling strategies for verifying the accuracy of our instrumentation and understanding device–solution interactions, both in vivo and in vitro. Included with this publication is a dataset containing both in vitro and in vivo device characterizations, as well as some examples of modeling and error structure analysis results. These data can be used for more detailed interpretation of neural recordings performed on common electrode types, providing a more complete picture of their properties than is often available to users.


  • Electrical rejuvenation of chronically implanted macroelectrodes in nonhuman primates

    by K P O’sUllivan, M E Orazem, K J Otto, C R Butson, J L Baker

    Objective. Electrodes chronically implanted in the brain undergo complex changes over time that can lower the signal to noise ratio (SNR) of recorded signals and reduce the amount of energy delivered to the tissue during therapeutic stimulation, both of which are relevant for the development of robust, closed-loop control systems. Several factors have been identified that link changes in the electrode-tissue interface (ETI) to increased impedance and degraded performance in micro- and macro-electrodes. Previous studies have demonstrated that brief pulses applied every few days can restore SNR to near baseline levels during microelectrode recordings in rodents, a process referred to as electrical rejuvenation. However, electrical rejuvenation has not been tested in clinically relevant macroelectrode designs in large animal models, which could serve as preliminary data for translation of this technique. Here, several variations of this approach were tested to characterize parameters for optimization. Approach. Alternating-current (AC) and direct-current (DC) electrical rejuvenation methods were explored in three electrode types, chronically implanted in two adult male nonhuman primates (NHP) (Macaca mulatta), which included epidural electrocorticography (ECoG) electrodes and penetrating deep-brain stimulation (DBS) electrodes. Electrochemical impedance spectroscopy (EIS) was performed before and after each rejuvenation paradigm as a gold standard measure of impedance, as well as at subsequent intervals to longitudinally track the evolution of the ETI. Stochastic error modeling was performed to assess the standard deviation of the impedance data, and consistency with the Kramers–Kronig relations was assessed to evaluate the stationarity of EIS measurement. Main results. AC and DC rejuvenation were found to quickly reduce impedance and minimize the tissue component of the ETI on all three electrode types, with DC and low-frequency AC producing the largest impedance drops and reduction of the tissue component in Nyquist plots. The effects of a single rejuvenation session were found to last from several days to over 1 week, and all rejuvenation pulses induced no observable changes to the animals’ behavior. Significance. These results demonstrate the effectiveness of electrical rejuvenation for diminishing the impact of chronic ETI changes in NHP with clinically relevant macroelectrode designs.