Ian Jentz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ian Jentz has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Brett Andrew Prussack
Department of Mechanical Engineering, University of Wisconsin–Madison, 1513 University Ave., Madison, WI 53706
2 shared publications - Dan J. Thoma
Department of Materials Science and Engineering, University of Wisconsin-Madison, Madison, USA
2 shared publications - Mark H. Anderson
University of Wisconsin–Madison
2 shared publications - Nicolas Woolstenhulme
Idaho National Laboratory (INL), Idaho Falls, ID (United States)
2 shared publications - Anthony M. Grotjan1 shared publication
Austen Fradeneck
1 shared publication
Latest Publications
- Open Access
- 23 June 2026
- Published by Elsevier in SSRN Electronic Journal
Edge Effects on the Pressure Drop Through Triply Periodic Minimal Surface Heat Exchangers
Triply periodic minimal surface (TPMS) geometries offer significant potential for compact, high-performance heat exchangers, but the influence of cross-sectional confinement on pressure drop of small-scale TPMS test articles remains unquantified. Truncation of the periodic structure introduces wall-induced edge effects that can substantially distort measured pressure drop and flow uniformity, compromising the extrapolation of sub-scale experimental data to full-scale heat exchanger performance.This study presents the first systematic isolation of the cross-sectional unit cell count effect on Diamond TPMS pressure drop under physical no-slip boundary conditions, combining experimental measurements (1×1 through 6×6 configurations, Re = 125–7500), CFD simulations (Re up to 8000), flow field visualization, and region-resolved hydrodynamic analysis. A curve fit is developed that collapses the per-unit-length pressure drop ratio across the Re = 3000–8000 range into a single equation, enabling direct estimation of the confinement penalty and extrapolation to the infinite-lattice asymptote for the studied geometry. CFD predictions agree with experimental measurements to within a mean absolute error of 9% for the 1×1 through 3×3 configurations and within 15% across the full 1×1 through 6×6 range.Preliminary testing on alternative Diamond TPMS configurations confirmed that the qualitative mechanisms responsible for edge effects extend beyond the specific geometry studied here, though the quantitative magnitude of the confinement penalty is geometry-dependent. Flow field visualization and region-resolved analysis identify the underlying physical mechanisms: corner recirculation in dead-end pockets of rearward-facing lattice peaks and high-velocity channeling through diagonally opposing forward-facing corners produce a previously uncharacterized spatial asymmetry that scales predictably with cross-sectional size. These findings deliver a geometry-specific scaling law for the 75D Diamond TPMS and a transferable mechanistic framework for interpreting sub-scale TPMS test data in nuclear, aerospace, and high-power-density thermal management applications.
- 23 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEdge Effects on the Pressure Drop Through Triply Periodic Minimal Surface Heat Exchangers
Triply periodic minimal surface (TPMS) geometries offer significant potential for compact, high-performance heat exchangers, but the influence of cross-sectional confinement on pressure drop of small-scale TPMS test articles remains unquantified. Truncation of the periodic structure introduces wall-induced edge effects that can substantially distort measured pressure drop and flow uniformity, compromising the extrapolation of sub-scale experimental data to full-scale heat exchanger performance.This study presents the first systematic isolation of the cross-sectional unit cell count effect on Diamond TPMS pressure drop under physical no-slip boundary conditions, combining experimental measurements (1×1 through 6×6 configurations, Re = 125–7500), CFD simulations (Re up to 8000), flow field visualization, and region-resolved hydrodynamic analysis. A curve fit is developed that collapses the per-unit-length pressure drop ratio across the Re = 3000–8000 range into a single equation, enabling direct estimation of the confinement penalty and extrapolation to the infinite-lattice asymptote for the studied geometry. CFD predictions agree with experimental measurements to within a mean absolute error of 9% for the 1×1 through 3×3 configurations and within 15% across the full 1×1 through 6×6 range.Preliminary testing on alternative Diamond TPMS configurations confirmed that the qualitative mechanisms responsible for edge effects extend beyond the specific geometry studied here, though the quantitative magnitude of the confinement penalty is geometry-dependent. Flow field visualization and region-resolved analysis identify the underlying physical mechanisms: corner recirculation in dead-end pockets of rearward-facing lattice peaks and high-velocity channeling through diagonally opposing forward-facing corners produce a previously uncharacterized spatial asymmetry that scales predictably with cross-sectional size. These findings deliver a geometry-specific scaling law for the 75D Diamond TPMS and a transferable mechanistic framework for interpreting sub-scale TPMS test data in nuclear, aerospace, and high-power-density thermal management applications.
- 17 March 2026
- Published by Elsevier in Applied Thermal Engineering
- Vol. 295
Scaling considerations for supercritical carbon dioxide cycles including turbomachinery loss models
- 17 March 2026
- Published by Elsevier in Applied Thermal Engineering
- Vol. 295
Scaling considerations for supercritical carbon dioxide cycles including turbomachinery loss models
- 17 October 2024
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 236
3D topology optimization and additive manufacturability of two-fluid heat exchangers
- 17 October 2024
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 236
3D topology optimization and additive manufacturability of two-fluid heat exchangers
- 1 May 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 248
Thermal and hydraulic performance of volumetrically heated triply periodic minimal surface heaters
- 1 May 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 248
Thermal and hydraulic performance of volumetrically heated triply periodic minimal surface heaters
- 3 August 2020
- Published by ASME International
Allowable Stress Development of Diffusion Bonded Alloy 800H for Section III
There is increased interest in the application of compact heat exchangers (CHXs) for nuclear service given their high thermal efficiency and compactness. CHXs are fabricated by joining a stack of etched plates with dense microchannels through diffusion bonding. Diffusion bonding material has basic mechanical properties that differ from a base material, requiring appropriate mechanical properties and allowable stresses for design. Existing nuclear code ASME Section III, Division 5 does not address diffusion bonded materials . Hence, there is a need to develop material properties and allowable stresses of diffusion bonded materials and weldments. In this paper, one candidate material, Alloy 800H, was selected for diffusion bonding trials. Preliminary results obtained from a series of tensile and creep tests suggest that the diffusion bonded material is weaker than the base metal 800H. These experimental data are used in determining recommended allowable stresses of the diffusion bonded 800H material. In this paper, tables of the strength reduction factors for various allowable stresses which includes Smt, So, St, Sy and Su for diffusion bonded Alloy 800H are presented. These reduction factors are applicable to CHX design. The Larson Miller Parameter (LMP) is used to extrapolate short term creep tests to longer creep life and lower temperatures, and estimate the onset of tertiary creep strain.
- 3 August 2020
- Published by ASME International
Allowable Stress Development of Diffusion Bonded Alloy 800H for Section III
There is increased interest in the application of compact heat exchangers (CHXs) for nuclear service given their high thermal efficiency and compactness. CHXs are fabricated by joining a stack of etched plates with dense microchannels through diffusion bonding. Diffusion bonding material has basic mechanical properties that differ from a base material, requiring appropriate mechanical properties and allowable stresses for design. Existing nuclear code ASME Section III, Division 5 does not address diffusion bonded materials . Hence, there is a need to develop material properties and allowable stresses of diffusion bonded materials and weldments. In this paper, one candidate material, Alloy 800H, was selected for diffusion bonding trials. Preliminary results obtained from a series of tensile and creep tests suggest that the diffusion bonded material is weaker than the base metal 800H. These experimental data are used in determining recommended allowable stresses of the diffusion bonded 800H material. In this paper, tables of the strength reduction factors for various allowable stresses which includes Smt, So, St, Sy and Su for diffusion bonded Alloy 800H are presented. These reduction factors are applicable to CHX design. The Larson Miller Parameter (LMP) is used to extrapolate short term creep tests to longer creep life and lower temperatures, and estimate the onset of tertiary creep strain.