Ilmars Bode
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ilmars Bode has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Laila Zemite
Institute of Industrial Electronics, Electrical Engineering and Energy, Riga Technical University, Faculty of Electrical and Environmental Engineering, Riga, Latvia
3 shared publications - Leo Jansons
Faculty of Civil and Mechanical Engineering, Riga Technical University, 6A Kipsala Street, LV-1048 Riga, Latvia
3 shared publications - Davids Kronkalns
Faculty of Computer Science, Information Technology and Energy, Riga Technical University, 12-1 Azenes Str., LV-1048 Riga, Latvia
2 shared publications - Egils Dzelzitis
Faculty of Computer Science, Information Technology and Energy, Institute of Power Engineering, Riga Technical University, 12-1 Azenes Str., LV-1048 Riga, Latvia
1 shared publication - Egils Dzelzitis
Faculty of Civil and Mechanical Engineering, Riga Technical University, 6A Kipsala Street, LV-1048 Riga, Latvia
1 shared publication - Ineta Geipele
Institute of Civil Engineering, Riga Technical University, 6A Kipsalas Str., LV-1048 Riga, Latvia
1 shared publication
Latest Publications
- Open Access
- 15 July 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (14) , 7217
Hydrogen for Heat: A District Heating Case Study from Latvia
Decarbonization of district heating (DH) systems requires practical solutions that can reduce greenhouse-gas (GHG) emissions while utilizing existing infrastructure. Therefore, the study experimentally evaluates hydrogen–methane-based gas co-combustion in a real urban DH installation in Riga, Latvia, using a 6.3 MW hot-water boiler operating under commercial conditions without equipment modification. Experiments were conducted under steady-state operating conditions by blending hydrogen with the baseline methane-based gas at volumetric fractions of 0%, 10%, and 20%. Thermal performance and emissions (CO2, NOx, and CO) were monitored during 30 min measurement periods, and three independent experiments were performed for each hydrogen blending level. The experimental data were analyzed using one-way analysis of variance (ANOVA) to evaluate the statistical significance of the observed changes. Stable ignition, flame anchoring, and load-following performance were maintained under all investigated conditions, and no flashback or blow-off events occurred. Boiler efficiency remained essentially constant at approximately 92% (92.1–91.9%), while thermal output was maintained at 6.3 MW. When CO2 emissions were normalized to useful thermal energy output (kg CO2/MWh), the specific CO2 emission intensity decreased from 202 kg/MWh for pure methane-based gas operation to 161 kg/MWh at 20 vol.% hydrogen addition, corresponding to an approximately 20% reduction in the carbon intensity of delivered heat under the investigated operating conditions. Carbon monoxide (CO) emissions remained low (~6–7 mg/kWh) and particulate matter concentrations remained below 1 mg/m3. Nitrogen oxide emissions increased moderately from approximately 40 mg/kWh to 52 mg/kWh due to enhanced combustion temperatures but remained within applicable regulatory limits. No degradation of safety systems, fuel metering equipment, or infrastructure and no leakage events were observed during the experiments. The results demonstrate that hydrogen blending up to 20 vol.% can achieve substantial reductions in the carbon intensity of heat generation while preserving boiler performance and operational safety, confirming hydrogen co-combustion as a practical transitional decarbonization pathway for existing DH systems. They also uncover the potential of hydrogen blending to support the sustainable decarbonization of DH systems by reducing GHG emissions while preserving existing infrastructure and operational reliability.
- 15 July 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (14) , 7217
Open AccessHydrogen for Heat: A District Heating Case Study from Latvia
Decarbonization of district heating (DH) systems requires practical solutions that can reduce greenhouse-gas (GHG) emissions while utilizing existing infrastructure. Therefore, the study experimentally evaluates hydrogen–methane-based gas co-combustion in a real urban DH installation in Riga, Latvia, using a 6.3 MW hot-water boiler operating under commercial conditions without equipment modification. Experiments were conducted under steady-state operating conditions by blending hydrogen with the baseline methane-based gas at volumetric fractions of 0%, 10%, and 20%. Thermal performance and emissions (CO2, NOx, and CO) were monitored during 30 min measurement periods, and three independent experiments were performed for each hydrogen blending level. The experimental data were analyzed using one-way analysis of variance (ANOVA) to evaluate the statistical significance of the observed changes. Stable ignition, flame anchoring, and load-following performance were maintained under all investigated conditions, and no flashback or blow-off events occurred. Boiler efficiency remained essentially constant at approximately 92% (92.1–91.9%), while thermal output was maintained at 6.3 MW. When CO2 emissions were normalized to useful thermal energy output (kg CO2/MWh), the specific CO2 emission intensity decreased from 202 kg/MWh for pure methane-based gas operation to 161 kg/MWh at 20 vol.% hydrogen addition, corresponding to an approximately 20% reduction in the carbon intensity of delivered heat under the investigated operating conditions. Carbon monoxide (CO) emissions remained low (~6–7 mg/kWh) and particulate matter concentrations remained below 1 mg/m3. Nitrogen oxide emissions increased moderately from approximately 40 mg/kWh to 52 mg/kWh due to enhanced combustion temperatures but remained within applicable regulatory limits. No degradation of safety systems, fuel metering equipment, or infrastructure and no leakage events were observed during the experiments. The results demonstrate that hydrogen blending up to 20 vol.% can achieve substantial reductions in the carbon intensity of heat generation while preserving boiler performance and operational safety, confirming hydrogen co-combustion as a practical transitional decarbonization pathway for existing DH systems. They also uncover the potential of hydrogen blending to support the sustainable decarbonization of DH systems by reducing GHG emissions while preserving existing infrastructure and operational reliability.
- Open Access
- 24 June 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (13) , 6422
Decarbonizing Multi-Apartment Residential Buildings with Hydrogen: Performance, Costs, and Urban Integration
This study addresses the technical, environmental, economic, and systemic role of multi-apartment residential buildings as hydrogen consumption nodes within urban energy systems. A representative five-story building comprising 30 apartments and 2400–2800 m2 of heated floor area, located in a cold European climate, was modelled with an annual heat demand of approximately 185,000 kWh. Four heating configurations were assessed: a conventional natural gas/biomethane boiler (baseline), a hydrogen boiler, a hydrogen-fuel-cell combined heat and power (CHP) system, and a hybrid heat-pump–hydrogen solution. Dynamic simulations indicate that all hydrogen-based systems can fully satisfy space heating and domestic hot water demand without modifications to the internal hydronic distribution network. The fuel cell CHP achieved an overall efficiency of 93%. It generated approximately 54,000 kWh/year of on-site electricity, while the hybrid configuration reached a seasonal efficiency of 108% and the highest primary energy reduction (46%). Operational CO2 emissions decreased from 37,800 kg/year (gas baseline) to 1900 kg/year (green hydrogen boiler), 1200 kg/year (fuel cell CHP), and 900 kg/year (hybrid system), corresponding to reductions of up to 98%. Peak-load analysis demonstrated improved operational stability in CHP and hybrid systems, characterised by reduced cycling frequency and enhanced thermal resilience through hydrogen storage integration. Capital expenditure (CAPEX) ranged from 41,000 EUR (gas baseline) to 101,000 EUR (fuel cell CHP), reflecting additional storage, safety, and control requirements. Over a 20-year lifecycle (5% discount rate), the hybrid system achieved the lowest levelized cost of heat (0.076 EUR/kWh), followed by fuel cell CHP (0.081 EUR/kWh), compared to 0.087 EUR/kWh for gas. Payback periods ranged between 9 and 13 years, depending on configuration and hydrogen pricing assumptions. Sensitivity analysis identified a break-even hydrogen price of approximately 0.085 EUR/kWh, while carbon pricing above 100 EUR/t CO2 significantly improves economic competitiveness. District-scale aggregation modelling suggests that hydrogen-equipped multi-apartment buildings can reduce grid electricity imports by 30–40% through on-site generation and seasonal storage. The findings confirm that multi-apartment buildings offer structural and economic advantages for early hydrogen deployment compared to dispersed housing typologies. By combining high demand density, centralised infrastructure, and compatibility with sector-coupling strategies, such buildings can function as distributed energy hubs within decarbonized urban systems.
- 24 June 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (13) , 6422
Open AccessDecarbonizing Multi-Apartment Residential Buildings with Hydrogen: Performance, Costs, and Urban Integration
This study addresses the technical, environmental, economic, and systemic role of multi-apartment residential buildings as hydrogen consumption nodes within urban energy systems. A representative five-story building comprising 30 apartments and 2400–2800 m2 of heated floor area, located in a cold European climate, was modelled with an annual heat demand of approximately 185,000 kWh. Four heating configurations were assessed: a conventional natural gas/biomethane boiler (baseline), a hydrogen boiler, a hydrogen-fuel-cell combined heat and power (CHP) system, and a hybrid heat-pump–hydrogen solution. Dynamic simulations indicate that all hydrogen-based systems can fully satisfy space heating and domestic hot water demand without modifications to the internal hydronic distribution network. The fuel cell CHP achieved an overall efficiency of 93%. It generated approximately 54,000 kWh/year of on-site electricity, while the hybrid configuration reached a seasonal efficiency of 108% and the highest primary energy reduction (46%). Operational CO2 emissions decreased from 37,800 kg/year (gas baseline) to 1900 kg/year (green hydrogen boiler), 1200 kg/year (fuel cell CHP), and 900 kg/year (hybrid system), corresponding to reductions of up to 98%. Peak-load analysis demonstrated improved operational stability in CHP and hybrid systems, characterised by reduced cycling frequency and enhanced thermal resilience through hydrogen storage integration. Capital expenditure (CAPEX) ranged from 41,000 EUR (gas baseline) to 101,000 EUR (fuel cell CHP), reflecting additional storage, safety, and control requirements. Over a 20-year lifecycle (5% discount rate), the hybrid system achieved the lowest levelized cost of heat (0.076 EUR/kWh), followed by fuel cell CHP (0.081 EUR/kWh), compared to 0.087 EUR/kWh for gas. Payback periods ranged between 9 and 13 years, depending on configuration and hydrogen pricing assumptions. Sensitivity analysis identified a break-even hydrogen price of approximately 0.085 EUR/kWh, while carbon pricing above 100 EUR/t CO2 significantly improves economic competitiveness. District-scale aggregation modelling suggests that hydrogen-equipped multi-apartment buildings can reduce grid electricity imports by 30–40% through on-site generation and seasonal storage. The findings confirm that multi-apartment buildings offer structural and economic advantages for early hydrogen deployment compared to dispersed housing typologies. By combining high demand density, centralised infrastructure, and compatibility with sector-coupling strategies, such buildings can function as distributed energy hubs within decarbonized urban systems.
- Open Access
Integrating Renewable Energy Solutions in Small-Scale Industrial Facilities
The purpose of this study was to analyze the economical suitability of numerous on-site renewable electricity generation technologies which were intended to be used in a recently built industrial facility designed and utilized as a warehouse. The facility was located in the vicinity of Riga, Latvia. Data were collected and calculations were performed within the scope of the project “Mitigating Energy Poverty through Innovative Solutions” as part of several planned activities to address the broad spectrum of energy poverty and self-reliance issues in both the residential sector and small-scale industrial facilities. During the project, evaluations of various renewable energy technologies, including PV installations, wind energy installations, battery storage solutions, and hybrid technologies, were carried out. The aim of these evaluations was to develop an electricity production–consumption model for efficient and cost-effective energy use and to reduce greenhouse gas emissions from the test facility. A model was created and subsequent research scenarios were developed based on a payback period instead of the net present value criterion. The project was carried out over several steps to develop a calculation methodology. The open access databases of energy resource providers were used to evaluate statistical data and make forecasts for the analysis of the electricity consumption of companies. MATLAB/Simulink 23/2 was used for the data analysis, and the H-TEC method was employed. This made it possible to modulate the required production capacity as the model allowed for the addition of new modules to modules already installed. The project results proved that despite high initial investment costs, renewable energy sources and efficient storage systems can provide cost-effective solutions and reduce dependence on fossil fuels in the long term.
Open AccessIntegrating Renewable Energy Solutions in Small-Scale Industrial Facilities
The purpose of this study was to analyze the economical suitability of numerous on-site renewable electricity generation technologies which were intended to be used in a recently built industrial facility designed and utilized as a warehouse. The facility was located in the vicinity of Riga, Latvia. Data were collected and calculations were performed within the scope of the project “Mitigating Energy Poverty through Innovative Solutions” as part of several planned activities to address the broad spectrum of energy poverty and self-reliance issues in both the residential sector and small-scale industrial facilities. During the project, evaluations of various renewable energy technologies, including PV installations, wind energy installations, battery storage solutions, and hybrid technologies, were carried out. The aim of these evaluations was to develop an electricity production–consumption model for efficient and cost-effective energy use and to reduce greenhouse gas emissions from the test facility. A model was created and subsequent research scenarios were developed based on a payback period instead of the net present value criterion. The project was carried out over several steps to develop a calculation methodology. The open access databases of energy resource providers were used to evaluate statistical data and make forecasts for the analysis of the electricity consumption of companies. MATLAB/Simulink 23/2 was used for the data analysis, and the H-TEC method was employed. This made it possible to modulate the required production capacity as the model allowed for the addition of new modules to modules already installed. The project results proved that despite high initial investment costs, renewable energy sources and efficient storage systems can provide cost-effective solutions and reduce dependence on fossil fuels in the long term.