Shoufeng Jin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shoufeng Jin has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Qingyu Wang
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
2 shared publications Tao Xie
State Key Laboratory of Electrical Insulation and Power Equipment Xi'an Jiaotong University Xi'an China
2 shared publications- Zongren Peng
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
2 shared publications Di Hu
State Grid Anhui Electric Power Research Institute Hefei China
1 shared publicationDongfeng Yang
1 shared publication- Huidong Tian
State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University Xi'an, People's Republic of China
1 shared publication
Latest Publications
- Open Access
- 24 May 2024
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 18 (7) , 334-348
Analysis of electrical contact characteristics of strap contacts used in high voltage bushings under eccentric conditions
The contact finger electrical connection structure is a crucial component of high voltage bushings, and its safety and reliability directly impact the operational stability of the bushing. To investigate electrical contact performance of the contact finger under eccentric conditions, a three‐dimensional electrical, thermal, and force multi‐physics coupling calculation model was established. Additionally, a test platform was constructed to measure electrical contact characteristics of the contact finger. The contact characteristics of the contact finger when the male head was axially deflected and radially offset compared to the female head were obtained. The research findings indicate when the male head deflects axially, the contact force changes of the contact finger blades on both sides are opposite. Moreover, as the axial deflection angle of the male head increases, the resistance of the electrical connection structure shows a rising‐slow decreasing‐fluctuating trend. The resistance is highest at 3°, with a resistance increase rate of 7.35%. Furthermore, the resistance of the electrical connection structure varies with the radial offset of the male head, following a power function. Contact failure occurs when the radial offset is 1.31 mm, and the resistance increase rate reaches 24.9% at a radial offset of 1.58 mm.
- 24 May 2024
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 18 (7) , 334-348
Open AccessAnalysis of electrical contact characteristics of strap contacts used in high voltage bushings under eccentric conditions
The contact finger electrical connection structure is a crucial component of high voltage bushings, and its safety and reliability directly impact the operational stability of the bushing. To investigate electrical contact performance of the contact finger under eccentric conditions, a three‐dimensional electrical, thermal, and force multi‐physics coupling calculation model was established. Additionally, a test platform was constructed to measure electrical contact characteristics of the contact finger. The contact characteristics of the contact finger when the male head was axially deflected and radially offset compared to the female head were obtained. The research findings indicate when the male head deflects axially, the contact force changes of the contact finger blades on both sides are opposite. Moreover, as the axial deflection angle of the male head increases, the resistance of the electrical connection structure shows a rising‐slow decreasing‐fluctuating trend. The resistance is highest at 3°, with a resistance increase rate of 7.35%. Furthermore, the resistance of the electrical connection structure varies with the radial offset of the male head, following a power function. Contact failure occurs when the radial offset is 1.31 mm, and the resistance increase rate reaches 24.9% at a radial offset of 1.58 mm.
- 10 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (5) , 2402-2411
Contact Failure Characteristic Test and Overheating Analysis of UHV GIL Electrical Connection Structure
As the key component of the conductor of the gas-insulated power transmission equipment, the electrical connection structure bears high current, high stress and high temperature for a long time. Electrical contact failures become an important issue, while it’s failure characteristics and mechanisms are ambiguous so far. In this paper, based on complex electrical connection structures of gas-insulated transmission line (GIL), equivalent tests were conducted on the contact failure characteristics of such structure. Result shows that poor contact of the such electrical connection structure will cause two types of situations: micro-gap discharge and contact overheating. The causes of both are different. Firstly, micro slip is a kind of cause of discharge faults despite the separation gap is small. The current transfer area (b) of such contact structure is the main position where the arc starts. The contact stability at that location should be fully considered in the layout of such electrical connection structure. Secondly, combined with the surface morphology and element distribution, the mechanism of contact discharge and the source of metal particles are further explained by the occurrence of coating peeling and material transfer behavior. Finally, the difference in contact state is the main reason for a few contacts overheating. There is a significant temperature difference between contacts in different contact state. The temperature rises nonlinearly with the increase of the current under the condition of uneven current carrying. The above research can provide a practical basis for fault analysis and prevention of such electric contact structures in the UHV gas-insulated power transmission equipment.
- 10 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (5) , 2402-2411
Contact Failure Characteristic Test and Overheating Analysis of UHV GIL Electrical Connection Structure
As the key component of the conductor of the gas-insulated power transmission equipment, the electrical connection structure bears high current, high stress and high temperature for a long time. Electrical contact failures become an important issue, while it’s failure characteristics and mechanisms are ambiguous so far. In this paper, based on complex electrical connection structures of gas-insulated transmission line (GIL), equivalent tests were conducted on the contact failure characteristics of such structure. Result shows that poor contact of the such electrical connection structure will cause two types of situations: micro-gap discharge and contact overheating. The causes of both are different. Firstly, micro slip is a kind of cause of discharge faults despite the separation gap is small. The current transfer area (b) of such contact structure is the main position where the arc starts. The contact stability at that location should be fully considered in the layout of such electrical connection structure. Secondly, combined with the surface morphology and element distribution, the mechanism of contact discharge and the source of metal particles are further explained by the occurrence of coating peeling and material transfer behavior. Finally, the difference in contact state is the main reason for a few contacts overheating. There is a significant temperature difference between contacts in different contact state. The temperature rises nonlinearly with the increase of the current under the condition of uneven current carrying. The above research can provide a practical basis for fault analysis and prevention of such electric contact structures in the UHV gas-insulated power transmission equipment.
- Open Access
- 7 April 2021
- Published by DEStech Publications in DEStech Transactions on Materials Science and Engineering
- No. ameme
The Design and Optimization of Swing Automatic Paper Folding Mechanism
- 7 April 2021
- Published by DEStech Publications in DEStech Transactions on Materials Science and Engineering
- No. ameme
Open AccessThe Design and Optimization of Swing Automatic Paper Folding Mechanism
- Open Access
- 6 October 2019
- Published by Kaunas University of Technology (KTU) in Elektronika ir Elektrotechnika
- Vol. 25 (5) , 4-10
A Novel Information Fusion Method for Vision Perception and Location of Intelligent Industrial Robots
An improved SURF (Speeded-Up Robust Feature) algorithm is proposed to deal with the time-consuming and low precision of positioning of industrial robot. Hessian matrix determinant is used to extract feature points from the target image and a multi-scale spatial pyramid is constructed. The location and scale value of feature points are determined by neighbourhood non-maximum suppression method. The direction of feature points is defined as directional feature descriptors by the binary robust independent elementary feature (BRIEF). The progressive sample consensus (PROSAC) is used to carry out second precise matching and remove mismatching points based on the Hamming distance. Then, an affine transformation model is established to describe the relationship between the template and target images. Centroid coordinates of the target can be obtained based on the affine transformation. Comparative tests were carried out to demonstrate that the proposed method can effectively improve the recognition rate and positioning accuracy of the industrial robots. The average time consuming is less than 0.2 s, the matching accuracy is 96 %, and the positioning error of the robot is less than 1.5 mm. Therefore, the proposed method has practical application importance.
- 6 October 2019
- Published by Kaunas University of Technology (KTU) in Elektronika ir Elektrotechnika
- Vol. 25 (5) , 4-10
Open AccessA Novel Information Fusion Method for Vision Perception and Location of Intelligent Industrial Robots
An improved SURF (Speeded-Up Robust Feature) algorithm is proposed to deal with the time-consuming and low precision of positioning of industrial robot. Hessian matrix determinant is used to extract feature points from the target image and a multi-scale spatial pyramid is constructed. The location and scale value of feature points are determined by neighbourhood non-maximum suppression method. The direction of feature points is defined as directional feature descriptors by the binary robust independent elementary feature (BRIEF). The progressive sample consensus (PROSAC) is used to carry out second precise matching and remove mismatching points based on the Hamming distance. Then, an affine transformation model is established to describe the relationship between the template and target images. Centroid coordinates of the target can be obtained based on the affine transformation. Comparative tests were carried out to demonstrate that the proposed method can effectively improve the recognition rate and positioning accuracy of the industrial robots. The average time consuming is less than 0.2 s, the matching accuracy is 96 %, and the positioning error of the robot is less than 1.5 mm. Therefore, the proposed method has practical application importance.