Xun Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xun Zhou has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Zeyu Li
National Key Laboratory of Fundamental Science on Synthetic Vision, Sichuan University, Chengdu, 610064, China
3 shared publications- Zeyu Li
Duke University
3 shared publications - Dayong Wang
School of Physics and Optoelectronic Engineering, Beijing University of Technology, Beijing, China
2 shared publications Du Wang
Research Center of Laser Fusion, CAEP, Mianyang 621900, China
2 shared publicationsGuangbin Li
Research Center of Laser Fusion, CAEP, Mianyang 621900, China
2 shared publicationsHaochong Huang
College of Applied Sciences &Beijing Engineering Research Center of Precision Measurement Technology and Instrument, Beijing University of Technology, No. 100 Pingleyuan Rd., Beijing, 100124, China
2 shared publications
Latest Publications
- 25 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 11 (4) , 389-395
Nonlinear Optical Up-Conversion in Terahertz Parametric Process: Simulation and Experiment
We present a numerical method to model the nonlinear optical up-conversion in the terahertz (THz) parametric process. Specifically, we introduce the concept of competition between the spontaneous parametric down-conversion (SPDC) idler beam and the up-converted Stokes beam. We simulate the spectra with the absolute power of each frequency component that clearly shows the competition result. By this method, we theoretically explain the suppression effect of injected signal on the SPDC idler background. We also verify the simulation experimentally by using an up-conversion parametric detection system. We show the competition result between the Stokes signal and SPDC idler background, the different levels of suppression caused by different input THz energy. The actual detection ability of the up-conversion system is also evaluated. All these experimental results are in good agreement with theoretical simulations. This research enables a comprehensive understanding of the physics of the up-conversion detection as well as the THz parametric generation and the seed injection.
- 25 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 11 (4) , 389-395
Nonlinear Optical Up-Conversion in Terahertz Parametric Process: Simulation and Experiment
We present a numerical method to model the nonlinear optical up-conversion in the terahertz (THz) parametric process. Specifically, we introduce the concept of competition between the spontaneous parametric down-conversion (SPDC) idler beam and the up-converted Stokes beam. We simulate the spectra with the absolute power of each frequency component that clearly shows the competition result. By this method, we theoretically explain the suppression effect of injected signal on the SPDC idler background. We also verify the simulation experimentally by using an up-conversion parametric detection system. We show the competition result between the Stokes signal and SPDC idler background, the different levels of suppression caused by different input THz energy. The actual detection ability of the up-conversion system is also evaluated. All these experimental results are in good agreement with theoretical simulations. This research enables a comprehensive understanding of the physics of the up-conversion detection as well as the THz parametric generation and the seed injection.
- 15 November 2019
- Published by Optica Publishing Group in Photonics Research
- Vol. 7 (12) , 1391-1399
Terahertz synthetic aperture in-line holography with intensity correction and sparsity autofocusing reconstruction
We demonstrate high-resolution and high-quality terahertz (THz) in-line digital holography based on the synthetic aperture method. The setup is built on a self-developed THz quantum cascade laser, and a lateral resolution better than 70 μm () is achieved at 4.3 THz. To correct intensity differences between sub-holograms before aperture stitching, a practical algorithm with global optimization is proposed. To address the twin-image problem for in-line holography, a sparsity-based phase retrieval algorithm is applied to perform the high-quality reconstruction. Furthermore, a new autofocusing criterion termed “reconstruction objective function” is introduced to obtain the best in-focus reconstruction distance, so the autofocusing procedure and the reconstruction are unified within the same framework. Both simulation and experiment prove its accuracy and robustness. Note that all the methods proposed here can be applied to other wavebands as well. We demonstrate the success of this THz synthetic aperture in-line holography on biological and semiconductor samples, showing its potential applications in bioimaging and materials analysis.- 15 November 2019
- Published by Optica Publishing Group in Photonics Research
- Vol. 7 (12) , 1391-1399
Terahertz synthetic aperture in-line holography with intensity correction and sparsity autofocusing reconstruction
We demonstrate high-resolution and high-quality terahertz (THz) in-line digital holography based on the synthetic aperture method. The setup is built on a self-developed THz quantum cascade laser, and a lateral resolution better than 70 μm () is achieved at 4.3 THz. To correct intensity differences between sub-holograms before aperture stitching, a practical algorithm with global optimization is proposed. To address the twin-image problem for in-line holography, a sparsity-based phase retrieval algorithm is applied to perform the high-quality reconstruction. Furthermore, a new autofocusing criterion termed “reconstruction objective function” is introduced to obtain the best in-focus reconstruction distance, so the autofocusing procedure and the reconstruction are unified within the same framework. Both simulation and experiment prove its accuracy and robustness. Note that all the methods proposed here can be applied to other wavebands as well. We demonstrate the success of this THz synthetic aperture in-line holography on biological and semiconductor samples, showing its potential applications in bioimaging and materials analysis.- 8 January 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (2) , 702-713
Sparsity-based continuous wave terahertz lens-free on-chip holography with sub-wavelength resolution
We demonstrate terahertz (THz) lens-free in-line holography on a chip in order to achieve 40 μm spatial resolution corresponding to ~0.7λ with a numerical aperture of ~0.87. We believe that this is the first time that sub-wavelength resolution in THz holography and the 40 μm resolution were both far better than what was already reported. The setup is based on a self-developed high-power continuous wave THz laser at 5.24 THz (λ = 57.25 μm) and a high-resolution microbolometer detector array (640 × 512 pixels) with a pitch of 17 μm. This on-chip in-line holography, however, suffers from the twin-image artifacts which obfuscate the reconstruction. To address this problem, we propose an iterative optimization framework, where the conventional object constraint and the L1 sparsity constraint can be combined to efficiently reconstruct the complex amplitude distribution of the sample. Note that the proposed framework and the sparsity-based algorithm can be applied to holography in other wavebands without limitation of wavelength. We demonstrate the success of this sparsity-based on-chip holography by imaging biological samples (i.e., a dragonfly wing and a bauhinia leaf).
- 8 January 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (2) , 702-713
Sparsity-based continuous wave terahertz lens-free on-chip holography with sub-wavelength resolution
We demonstrate terahertz (THz) lens-free in-line holography on a chip in order to achieve 40 μm spatial resolution corresponding to ~0.7λ with a numerical aperture of ~0.87. We believe that this is the first time that sub-wavelength resolution in THz holography and the 40 μm resolution were both far better than what was already reported. The setup is based on a self-developed high-power continuous wave THz laser at 5.24 THz (λ = 57.25 μm) and a high-resolution microbolometer detector array (640 × 512 pixels) with a pitch of 17 μm. This on-chip in-line holography, however, suffers from the twin-image artifacts which obfuscate the reconstruction. To address this problem, we propose an iterative optimization framework, where the conventional object constraint and the L1 sparsity constraint can be combined to efficiently reconstruct the complex amplitude distribution of the sample. Note that the proposed framework and the sparsity-based algorithm can be applied to holography in other wavebands without limitation of wavelength. We demonstrate the success of this sparsity-based on-chip holography by imaging biological samples (i.e., a dragonfly wing and a bauhinia leaf).
- Open Access
- 1 September 2016
- Published by Optica Publishing Group in Optics Express
- Vol. 24 (18) , 21134-21146
Resolution and quality enhancement in terahertz in-line holography by sub-pixel sampling with double-distance reconstruction
We demonstrate the enhancement of resolution and image quality in terahertz (THz) lens-free in-line digital holography by sub-pixel sampling with double-distance reconstruction. Multiple sub-pixel shifted low-resolution (LR) holograms recorded by a pyroelectric array detector (100 μm × 100 μm pixel pitch, 124 × 124 pixels) are aligned precisely to synthesize a high-resolution (HR) hologram. By this method, the lateral resolution is no more limited by the pixel pitch, and lateral resolution of 150 μm is obtained, which corresponds to 1.26λ with respect to the illuminating wavelength of 118.8 μm (2.52 THz). Compared with other published works, to date, this is the highest resolution in THz digital holography when considering the illuminating wavelength. In addition, to suppress the twin-image and zero-order artifacts, the complex amplitude distributions of both object and illuminaing background wave fields are reconstructed simultaneously. This is achieved by iterative phase retrieval between the double HR holograms and background images at two recording planes, which does not require any constraints on object plane or a priori knowledge of the sample.
- 1 September 2016
- Published by Optica Publishing Group in Optics Express
- Vol. 24 (18) , 21134-21146
Open AccessResolution and quality enhancement in terahertz in-line holography by sub-pixel sampling with double-distance reconstruction
We demonstrate the enhancement of resolution and image quality in terahertz (THz) lens-free in-line digital holography by sub-pixel sampling with double-distance reconstruction. Multiple sub-pixel shifted low-resolution (LR) holograms recorded by a pyroelectric array detector (100 μm × 100 μm pixel pitch, 124 × 124 pixels) are aligned precisely to synthesize a high-resolution (HR) hologram. By this method, the lateral resolution is no more limited by the pixel pitch, and lateral resolution of 150 μm is obtained, which corresponds to 1.26λ with respect to the illuminating wavelength of 118.8 μm (2.52 THz). Compared with other published works, to date, this is the highest resolution in THz digital holography when considering the illuminating wavelength. In addition, to suppress the twin-image and zero-order artifacts, the complex amplitude distributions of both object and illuminaing background wave fields are reconstructed simultaneously. This is achieved by iterative phase retrieval between the double HR holograms and background images at two recording planes, which does not require any constraints on object plane or a priori knowledge of the sample.
- Open Access
- 13 February 2015
- Published by Springer Nature in Scientific Reports
- Vol. 5 (1) , srep08445-8445
Terahertz in-line digital holography of human hepatocellular carcinoma tissue
Terahertz waves provide a better contrast in imaging soft biomedical tissues than X-rays and unlike X-rays, they cause no ionisation damage, making them a good option for biomedical imaging. Terahertz absorption imaging has conventionally been used for cancer diagnosis. However, the absorption properties of a cancerous sample are influenced by two opposing factors: an increase in absorption due to a higher degree of hydration and a decrease in absorption due to structural changes. It is therefore difficult to diagnose cancer from an absorption image. Phase imaging can thus be critical for diagnostics. We demonstrate imaging of the absorption and phase-shift distributions of 3.2 mm × 2.3 mm × 30-μm-thick human hepatocellular carcinoma tissue by continuous-wave terahertz digital in-line holography. The acquisition time of a few seconds for a single in-line hologram is much shorter than that of other terahertz diagnostic techniques and future detectors will allow acquisition of meaningful holograms without sample dehydration. The resolution of the reconstructions was enhanced by sub-pixel shifting and extrapolation. Another advantage of this technique is its relaxed minimal sample size limitation. The fibrosis indicated in the phase distribution demonstrates the potential of terahertz holographic imaging to obtain a more objective, early diagnosis of cancer.
- 13 February 2015
- Published by Springer Nature in Scientific Reports
- Vol. 5 (1) , srep08445-8445
Open AccessTerahertz in-line digital holography of human hepatocellular carcinoma tissue
Terahertz waves provide a better contrast in imaging soft biomedical tissues than X-rays and unlike X-rays, they cause no ionisation damage, making them a good option for biomedical imaging. Terahertz absorption imaging has conventionally been used for cancer diagnosis. However, the absorption properties of a cancerous sample are influenced by two opposing factors: an increase in absorption due to a higher degree of hydration and a decrease in absorption due to structural changes. It is therefore difficult to diagnose cancer from an absorption image. Phase imaging can thus be critical for diagnostics. We demonstrate imaging of the absorption and phase-shift distributions of 3.2 mm × 2.3 mm × 30-μm-thick human hepatocellular carcinoma tissue by continuous-wave terahertz digital in-line holography. The acquisition time of a few seconds for a single in-line hologram is much shorter than that of other terahertz diagnostic techniques and future detectors will allow acquisition of meaningful holograms without sample dehydration. The resolution of the reconstructions was enhanced by sub-pixel shifting and extrapolation. Another advantage of this technique is its relaxed minimal sample size limitation. The fibrosis indicated in the phase distribution demonstrates the potential of terahertz holographic imaging to obtain a more objective, early diagnosis of cancer.
- Open Access
- 8 July 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (14) , 17236-17245
Terahertz in-line digital holography of dragonfly hindwing: amplitude and phase reconstruction at enhanced resolution by extrapolation
We report here on terahertz (THz) digital holography on a biological specimen. A continuous-wave (CW) THz in-line holographic setup was built based on a 2.52 THz CO2 pumped THz laser and a pyroelectric array detector. We introduced novel statistical method of obtaining true intensity values for the pyroelectric array detector’s pixels. Absorption and phase-shifting images of a dragonfly’s hindwing were reconstructed simultaneously from single in-line hologram. Furthermore, we applied phase retrieval routines to eliminate twin image and enhanced the resolution of the reconstructions by hologram extrapolation beyond the detector area. The finest observed features are 35 μm width cross veins.
- 8 July 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (14) , 17236-17245
Open AccessTerahertz in-line digital holography of dragonfly hindwing: amplitude and phase reconstruction at enhanced resolution by extrapolation
We report here on terahertz (THz) digital holography on a biological specimen. A continuous-wave (CW) THz in-line holographic setup was built based on a 2.52 THz CO2 pumped THz laser and a pyroelectric array detector. We introduced novel statistical method of obtaining true intensity values for the pyroelectric array detector’s pixels. Absorption and phase-shifting images of a dragonfly’s hindwing were reconstructed simultaneously from single in-line hologram. Furthermore, we applied phase retrieval routines to eliminate twin image and enhanced the resolution of the reconstructions by hologram extrapolation beyond the detector area. The finest observed features are 35 μm width cross veins.