Han Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Han Wang has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Yueming Gao
College of Physics and Information Engineering, Fuzhou University, Fuzhou 350108, China
6 shared publications - Jiejie Yang
Fuzhou University
5 shared publications - Mang I. Vai
University of Macau
5 shared publications - Sio Hang Pun
State Key Laboratory of Analog and Mixed Signal VLSI, Institute of Microelectronics University of Macau Macau China
5 shared publications - Dongming Li
State Key Laboratory of Analog and Mixed-Signal VLSI, University of Macau, Macau, China
3 shared publications - Hung-Chun Li
Zhuhai UM Science and Technology Research Institute-Lingyange Semiconductor Incorporated Joint Laboratory, Zhuhai, China
3 shared publications
Latest Publications
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 74 (9) , 8476-8490
Bit-Level Modeling and Reception Analysis of Concurrent Transmissions in Galvanic Coupled Communication
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 74 (9) , 8476-8490
Bit-Level Modeling and Reception Analysis of Concurrent Transmissions in Galvanic Coupled Communication
- 22 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
A Dynamic High-Fidelity Equivalent Circuit Phantom for Intracardiac Communication in Pacemaker Indications
Conductive intracardiac communication (CIC) is an essential approach for achieving multichamber pacing in leadless pacemakers (LCPs), significantly enhancing the therapeutic outcomes for conditions, such as bradycardia. However, the characteristics of the intracardiac channel are profoundly affected by the heart’s rhythmic contractions. Accurately understanding the dynamic transmission mechanisms and channel parameters under various cardiac pathological states is crucial for enhancing the multichamber pacing functionality of LCPs. In this article, the relationship between cardiac chamber volume and channel impedance is mapped based on the electrocardiogram (ECG) data. This mapping enables precise, real-time adjustments to variable impedance, simulating the impedance changes occurring with each heartbeat. Through this approach, a time-frequency equivalent circuit phantom is proposed to accurately simulate channel characteristics for various pacemaker indications (PIs). Utilizing a quasi-dual-pump structural analogy to the heart, we designed a dynamic experimental measurement platform capable of simulating the cardiac beating process under various PIs, which is employed to validate the accuracy of the circuit phantom. The results demonstrate that the correlation coefficients in the frequency and time domains are greater than 0.9432 and 0.9150, respectively, with a time-domain consistency coefficient of less than 3.25. Through cross validation in both frequency and time domains, the circuit effectively simulates the channel characteristics of normal and PI hearts. The empirical formula established based on the time-domain measurement results can be utilized for the rapid estimation of the right atrium (RA)–right ventricle (RV) channel characteristics. The proposed phantom offers a highly accurate and reproducible experimental method for the design of intracardiac communication transceivers, advancing the development and validation of leadless multichamber pacemaker systems.
- 22 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
A Dynamic High-Fidelity Equivalent Circuit Phantom for Intracardiac Communication in Pacemaker Indications
Conductive intracardiac communication (CIC) is an essential approach for achieving multichamber pacing in leadless pacemakers (LCPs), significantly enhancing the therapeutic outcomes for conditions, such as bradycardia. However, the characteristics of the intracardiac channel are profoundly affected by the heart’s rhythmic contractions. Accurately understanding the dynamic transmission mechanisms and channel parameters under various cardiac pathological states is crucial for enhancing the multichamber pacing functionality of LCPs. In this article, the relationship between cardiac chamber volume and channel impedance is mapped based on the electrocardiogram (ECG) data. This mapping enables precise, real-time adjustments to variable impedance, simulating the impedance changes occurring with each heartbeat. Through this approach, a time-frequency equivalent circuit phantom is proposed to accurately simulate channel characteristics for various pacemaker indications (PIs). Utilizing a quasi-dual-pump structural analogy to the heart, we designed a dynamic experimental measurement platform capable of simulating the cardiac beating process under various PIs, which is employed to validate the accuracy of the circuit phantom. The results demonstrate that the correlation coefficients in the frequency and time domains are greater than 0.9432 and 0.9150, respectively, with a time-domain consistency coefficient of less than 3.25. Through cross validation in both frequency and time domains, the circuit effectively simulates the channel characteristics of normal and PI hearts. The empirical formula established based on the time-domain measurement results can be utilized for the rapid estimation of the right atrium (RA)–right ventricle (RV) channel characteristics. The proposed phantom offers a highly accurate and reproducible experimental method for the design of intracardiac communication transceivers, advancing the development and validation of leadless multichamber pacemaker systems.
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Dynamic Path Gain Compensation for Enhancing Intracardiac Communication in Leadless Pacemakers
Leadless pacemakers (LCPs) have emerged as a viable solution to mitigate the side effects associated with traditional pacing leads. Nevertheless, the absence of suitable intracardiac communication methods restricts most LCPs to single-chamber pacing. Galvanic conductive communication (GCC) offers a promising approach for achieving intracardiac communication in multi-chamber LCPs. However, impedance mismatch between the receiver and myocardium during the cardiac cycle can lead to a reduction in path gain, thereby affecting communication stability. This paper proposed a dynamic compensation method to reduce impedance mismatch and enhance communication stability. We developed a simplified LCP system with dynamic path gain compensation and validated it on an ex vivo porcine heart dynamic experimental platform. The results demonstrated a path gain improvement of 9.23 dB and a reduction in path gain variation from 3.95 dB to 0.3 dB. Additionally, the bit error rate (BER) decreased by over 50% across various transmission rates, with the most significant improvement observed at 5 kbps, where it decreased by 82.7%. These findings provide a high-reliability solution for intracardiac communication and establish a foundation for future multi-chamber sequential pacing applications in LCPs.
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Dynamic Path Gain Compensation for Enhancing Intracardiac Communication in Leadless Pacemakers
Leadless pacemakers (LCPs) have emerged as a viable solution to mitigate the side effects associated with traditional pacing leads. Nevertheless, the absence of suitable intracardiac communication methods restricts most LCPs to single-chamber pacing. Galvanic conductive communication (GCC) offers a promising approach for achieving intracardiac communication in multi-chamber LCPs. However, impedance mismatch between the receiver and myocardium during the cardiac cycle can lead to a reduction in path gain, thereby affecting communication stability. This paper proposed a dynamic compensation method to reduce impedance mismatch and enhance communication stability. We developed a simplified LCP system with dynamic path gain compensation and validated it on an ex vivo porcine heart dynamic experimental platform. The results demonstrated a path gain improvement of 9.23 dB and a reduction in path gain variation from 3.95 dB to 0.3 dB. Additionally, the bit error rate (BER) decreased by over 50% across various transmission rates, with the most significant improvement observed at 5 kbps, where it decreased by 82.7%. These findings provide a high-reliability solution for intracardiac communication and establish a foundation for future multi-chamber sequential pacing applications in LCPs.
- 22 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (4) , 815-826
Analysis and Circuit Design of Imbalanced Impedance Channels for Conductive Intracardiac Communication
Conductive Intracardiac Communication (CIC) uses cardiac tissue as a transmission medium for short-range wireless communication and is a potential method for enabling leadless multi-chamber pacing. However, the characterization of the intracardiac channel is significantly influenced by the experimental setup and conditions. The reported results in the literature vary depending on the measurement methods used, posing challenges in obtaining reliable channel characterization for CIC. In this paper, we aim to investigate the effects of different measurement devices and conditions on the intracardiac channel. By clarifying how impedance imbalance affects the gain measurement results, we design a weak-signal measurement circuit with high common-mode rejection. This new circuit provides a more accurate and effective gain measurement scheme for the CIC channel. An equivalent circuit model simulating cardiac biomechanical impedance is constructed to analyze how capacitive and resistive imbalances affect the gain measurement results. The effects of these imbalances are verified by intracardiac channel impedance imbalance experiments. A high common-mode rejection-high-resistance differential measurement circuit that can reduce the effects of capacitive and resistive imbalances simultaneously, is then designed to suppress the interference in the experiments. The results show that changes in the measurement equipment and isolation method lead to variations in the coupling circuit characteristics, causing differences of up to 16.65 dB in the measurement results. Experiments using the designed measurement circuits effectively mitigate interference from impedance imbalance on the measurement results. This study identifies the reasons behind the discrepancies in the experimental results of previous studies and provides a more reliable gain measurement scheme for CIC research.
- 22 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (4) , 815-826
Analysis and Circuit Design of Imbalanced Impedance Channels for Conductive Intracardiac Communication
Conductive Intracardiac Communication (CIC) uses cardiac tissue as a transmission medium for short-range wireless communication and is a potential method for enabling leadless multi-chamber pacing. However, the characterization of the intracardiac channel is significantly influenced by the experimental setup and conditions. The reported results in the literature vary depending on the measurement methods used, posing challenges in obtaining reliable channel characterization for CIC. In this paper, we aim to investigate the effects of different measurement devices and conditions on the intracardiac channel. By clarifying how impedance imbalance affects the gain measurement results, we design a weak-signal measurement circuit with high common-mode rejection. This new circuit provides a more accurate and effective gain measurement scheme for the CIC channel. An equivalent circuit model simulating cardiac biomechanical impedance is constructed to analyze how capacitive and resistive imbalances affect the gain measurement results. The effects of these imbalances are verified by intracardiac channel impedance imbalance experiments. A high common-mode rejection-high-resistance differential measurement circuit that can reduce the effects of capacitive and resistive imbalances simultaneously, is then designed to suppress the interference in the experiments. The results show that changes in the measurement equipment and isolation method lead to variations in the coupling circuit characteristics, causing differences of up to 16.65 dB in the measurement results. Experiments using the designed measurement circuits effectively mitigate interference from impedance imbalance on the measurement results. This study identifies the reasons behind the discrepancies in the experimental results of previous studies and provides a more reliable gain measurement scheme for CIC research.
- 1 June 2024
- Published by Springer Nature
- p. 160-169
Cardiac Phantoms for Signal Transmission Characteristics Analysis of Leadless Pacemakers
- 1 June 2024
- Published by Springer Nature
- p. 160-169
Cardiac Phantoms for Signal Transmission Characteristics Analysis of Leadless Pacemakers
- 1 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (4) , 872-884
A Time-Varying Equivalent Circuit Modeling and Measuring Approach for Intracardiac Communication in Leadless Pacemakers
Intracardiac wireless communication is crucial for the development of multi-chamber leadless cardiac pacemakers (LCP). However, the time-varying characteristics of intracardiac channel pose major challenges. As such, mastering the dynamic conduction properties of the intracardiac channel and modeling the equivalent time-varying channel are imperative for realizing LCP multi-chamber pacing. In this paper, we present a limiting volume variational approach based on the electrical properties of cardiac tissues and trends in chamber volume variation. This approach was used to establish a quasi-static and a continuous time-varying equivalent circuit model of an intracardiac channel. An equivalence analysis was conducted on the model, and a discrete time-varying equivalent circuit phantom grounded on the cardiac cycle was subsequently established. Moreover, an ex vivo cardiac experimental platform was developed for verification. Results indicate that in the frequency domain, the congruence between phantom and ex vivo experimental outcomes is as high as 94.3%, affirming the reliability of the equivalent circuit model. In the time domain, the correlation is up to 75.3%, corroborating its effectiveness. The proposed time-varying equivalent circuit model exhibits stable and standardized dynamic attributes, serving as a powerful tool for addressing time-varying challenges and simplifying in vivo or ex vivo experiments.
- 1 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (4) , 872-884
A Time-Varying Equivalent Circuit Modeling and Measuring Approach for Intracardiac Communication in Leadless Pacemakers
Intracardiac wireless communication is crucial for the development of multi-chamber leadless cardiac pacemakers (LCP). However, the time-varying characteristics of intracardiac channel pose major challenges. As such, mastering the dynamic conduction properties of the intracardiac channel and modeling the equivalent time-varying channel are imperative for realizing LCP multi-chamber pacing. In this paper, we present a limiting volume variational approach based on the electrical properties of cardiac tissues and trends in chamber volume variation. This approach was used to establish a quasi-static and a continuous time-varying equivalent circuit model of an intracardiac channel. An equivalence analysis was conducted on the model, and a discrete time-varying equivalent circuit phantom grounded on the cardiac cycle was subsequently established. Moreover, an ex vivo cardiac experimental platform was developed for verification. Results indicate that in the frequency domain, the congruence between phantom and ex vivo experimental outcomes is as high as 94.3%, affirming the reliability of the equivalent circuit model. In the time domain, the correlation is up to 75.3%, corroborating its effectiveness. The proposed time-varying equivalent circuit model exhibits stable and standardized dynamic attributes, serving as a powerful tool for addressing time-varying challenges and simplifying in vivo or ex vivo experiments.