YSY. R. Sun

Y. R. Sun

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Y. R. Sun has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • Shui-Ming Hu

    University of Science and Technology of China

    3 shared publications
  • X. Zheng

    Hefei National Laboratory for Physical Sciences and Microscale, iChem Center, University of Science and Technology of China, Hefei 230026, China

    3 shared publications
  • J.-J. Chen

    Hefei National Laboratory for Physical Sciences and Microscale, iChem Center, University of Science and Technology of China, Hefei 230026, China

    2 shared publications
  • Krzysztof Pachucki

    University of Warsaw

    2 shared publications
  • G.-P. Feng

    Hefei National Laboratory for Physical Sciences at the Microscale, Collaborative Innovation Center of Chemistry for Energy Materials, University of Science and Technology of China, Hefei 230026, China

    1 shared publication
  • Heifei 230026 Cas Center For Excellence In Quantum Information And Quantum Physics

    1 shared publication

Latest Publications

  • A bright and stable beam of slow metastable helium atoms

    by Jiao-Jiao Chen, Yu Sun, Jin-Lu Wen, Shui-Ming Hu, Heifei 230026 Cas Center For Excellence In Quantum Information And Quantum Physics

    稳定的高强度原子束流源是很多精密测量实验的关键. 亚稳态($2^3S$)氦原子的精密光谱测量在检验量子电动力学、测定精细结构常数研究中受到重要关注. 我们利用激光冷却方法增强束流强度、通过塞曼减速器降低原子的纵向速度, 并利用反馈控制稳定束流强度. 实验测得, 所产生的亚稳态氦原子连续束流在$100\pm 3.6$ m/s 速度下, 强度达$5.8\times 10^{12}$ atoms/s/sr, 相对稳定度为 0.021%. 利用该原子束, 我们示范了在仅0.1%的饱和光强条件下进行$^4{\rm{He}}$原子$2^3S-2^3P$跃迁的光谱探测, 此时由探测光功率带来的频移低于1 kHz.


  • Measurement of the Frequency of the2 S3−2 P3Transition ofHe4

    by X. Zheng, Y. R. Sun, J.-J. Chen, W. Jiang, K. Pachucki, S.-M. Hu

    The 2 S3–2 P3 transition of He4 was measured by comb-linked laser spectroscopy using a transverse-cooled atomic beam. The centroid frequency was determined to be 276 736 495 600.0(1.4) kHz, with a fractional uncertainty of 5.1×10−12. This value is not only more accurate but also differs by as much as −49.5  kHz (20σ) from the previous result given by [Cancio Pastor et al., Phys. Rev. Lett. 92, 023001 (2004); Cancio Pastor et al. Phys. Rev. Lett. 97, 139903(E) (2006); Cancio Pastor et al. Phys. Rev. Lett. 108, 143001 (2012)]. In combination with ongoing theoretical calculations, this work may allow the most accurate determination of the nuclear charge radius of helium.


  • Laser Spectroscopy of the Fine-Structure Splitting in the 2PJ3 Levels of He4

    by X. Zheng, Y. R. Sun, J.-J. Chen, W. Jiang, K. Pachucki, S.-M. Hu

    The fine-structure splitting in the 2PJ3 (J=0, 1, 2) levels of He4 is of great interest for tests of quantum electrodynamics and for the determination of the fine-structure constant α. The 2P03−2P23 and 2P13−2P23 intervals are measured by laser spectroscopy of the PJ3−2S13 transitions at 1083 nm in an atomic beam, and are determined to be 31 908 130.98±0.13  kHz and 2 291 177.56±0.19  kHz, respectively. Compared with calculations, which include terms up to α5Ry, the deviation for the α-sensitive interval 2P03−2P23 is only 0.22 kHz. It opens the window for further improvement of theoretical predictions and an independent determination of the fine-structure constant α with a precision of 2×10−9.


  • Open Access

    Laser-spectroscopy measurement of the fine-structure splitting23P1–23P2ofHe4

    by G.-P. Feng, X. Zheng, Y. R. Sun, S.-M. Hu

    Laser spectroscopy has been performed on a beam of neutral He4 atoms. By using transverse laser cooling and focusing, we are able to prepare a bright beam of atoms in the metastable state 23S1 deflected from the original effusive atomic beam. The initial state preparation is completed with optical pumping on the 23P1←23S1 transition at the wavelength of 1083 nm, followed by laser spectroscopy on the 23P1,2←23S1 transitions. The 23P1−23P2 fine-structure splitting is determined to be 2291177.69±0.36kHz. The quantum interference effect is included in data extraction. This is the most precise laser spectroscopy measurement of the interval. Our result is in agreement with both the latest QED-based calculation and the most precise measurement conducted with microwave spectroscopy.