Alex W. Mesny
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alex W. Mesny has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Carl M. Sangan
Department of Mechanical Engineering, University of Bath , Bath BA2 7AY, UK
6 shared publications - James A. Scobie
University of Bath
6 shared publications - Artur Joao Carvalho Figueiredo
Department of Mechanical Engineering, University of Bath, Bath BA2 7AY, UK
2 shared publications - B. Deneys J. Schreiner
Department of Mechanical Engineering, University of Bath, Bath BA2 7AY, UK
2 shared publications - David J. Cleaver
Department of Mechanical Engineering, University of Bath, Bath BA2 7AY, UK
2 shared publications - Giove De Cosmo
Turbomachinery Research Centre, Department of Mechanical Engineering, University of Bath , Bath BA2 7AY, UK
2 shared publications
Latest Publications
- 5 April 2024
- Published by Wiley in Journal of Turbomachinery
- Vol. 146 (9) , 1-22
Purge–Mainstream Interactions in a Turbine Stage With Rotor Endwall Contouring
Purge flows are prevalent in modern gas turbine design, allowing for increased turbine entry temperatures. The purge flow passes through a rim seal and interacts with the mainstream flow, modifying the blade secondary flow structures and reducing stage efficiency. These structures may be controlled using end wall contouring (EWC), though experimental demonstration of their benefit is seldom reported in the literature. The optically accessible turbine at the University of Bath was designed to directly measure and visualize the flow field within the blade passage for a rotor with EWC. The single-stage turbine enables phase-locked flow field measurements with volumetric particle image velocimetry (PIV). Purge flow was supplied to investigate a range of operating conditions in which the secondary flow structures were modified. The modular turbine rotor allowed for expedient change of a bladed ring, or bling, featuring non-axisymmetric EWC. The identified secondary flow structures were the pressure-side leg of the horse shoe vortex (PS-HSV) and an egress vortex (EV) of concurrent rotational direction. An increase in purge flowrate monotonically shifted the EV toward the suction-side (SS) of the adjacent blade. The migration of the PS-HSV toward the SS caused the two aforementioned vortices to merge. The EWC rotor design included a leading-edge (LE) feature to alter the PS-HSV and a trough to guide the EV low spanwise in the passage and maintain displacement from the adjacent suction-side. The EWC rotor was found to be effective at altering the formation and positioning of the secondary flow structures at a range of purge flow conditions.
- 5 April 2024
- Published by Wiley in Journal of Turbomachinery
- Vol. 146 (9) , 1-22
Purge–Mainstream Interactions in a Turbine Stage With Rotor Endwall Contouring
Purge flows are prevalent in modern gas turbine design, allowing for increased turbine entry temperatures. The purge flow passes through a rim seal and interacts with the mainstream flow, modifying the blade secondary flow structures and reducing stage efficiency. These structures may be controlled using end wall contouring (EWC), though experimental demonstration of their benefit is seldom reported in the literature. The optically accessible turbine at the University of Bath was designed to directly measure and visualize the flow field within the blade passage for a rotor with EWC. The single-stage turbine enables phase-locked flow field measurements with volumetric particle image velocimetry (PIV). Purge flow was supplied to investigate a range of operating conditions in which the secondary flow structures were modified. The modular turbine rotor allowed for expedient change of a bladed ring, or bling, featuring non-axisymmetric EWC. The identified secondary flow structures were the pressure-side leg of the horse shoe vortex (PS-HSV) and an egress vortex (EV) of concurrent rotational direction. An increase in purge flowrate monotonically shifted the EV toward the suction-side (SS) of the adjacent blade. The migration of the PS-HSV toward the SS caused the two aforementioned vortices to merge. The EWC rotor design included a leading-edge (LE) feature to alter the PS-HSV and a trough to guide the EV low spanwise in the passage and maintain displacement from the adjacent suction-side. The EWC rotor was found to be effective at altering the formation and positioning of the secondary flow structures at a range of purge flow conditions.
- 18 November 2021
- Published by Wiley in Journal of Turbomachinery
- Vol. 144 (4)
Vortex Tracking of Purge-Mainstream Interactions in a Rotating Turbine Stage
The use of purge flow in gas turbines allows for high turbine entry temperatures, which are essential to produce high cycle efficiency. Purge air is bled from the compressor and reintroduced in the turbine to cool vulnerable components. Wheel-spaces are formed between adjacent rotating and stationary discs, with purge air supplied at low radius before exiting into the mainstream gas-path through a rim-seal at the disc periphery. An aerodynamic penalty is incurred as the purge flow egress interacts with the mainstream. This study presents unparalleled three-dimensional velocity data from a single-stage turbine test rig, specifically designed to investigate egress–mainstream interaction using optical measurement techniques. Volumetric velocimetry is applied to the rotating environment with phase-locked measurements used to identify and track the vortical secondary flow features through the blade passage. A baseline case without purge flow is compared to experiments with a 1.7% purge mass fraction; the latter was chosen to ensure a fully sealed wheel-space. A non-localized vortex tracking function is applied to the data to identify the position of the core centroids. The strength of the secondary flow vortices was determined using a circulation criterion on rotated planes aligned to the vortex filaments. The pressure-side leg of the horseshoe vortex and a second vortex associated with the egress flow were identified by the experimental campaign. In the absence of purge flow, the two vortices merged, forming the passage vortex (PV). With the addition of purge flow, the two cores remained independent to 40% of the blade axial chord, while also demonstrating an increased radial migration and intensification of the PV. The egress core was shown to remain closer to the suction-surface with purge flow. Importantly, where the vortex filaments demonstrated strong radial or tangential components of velocity, the circulation level calculated from axial planes underpredicted the true circulation by up to 50%.
- 18 November 2021
- Published by Wiley in Journal of Turbomachinery
- Vol. 144 (4)
Vortex Tracking of Purge-Mainstream Interactions in a Rotating Turbine Stage
The use of purge flow in gas turbines allows for high turbine entry temperatures, which are essential to produce high cycle efficiency. Purge air is bled from the compressor and reintroduced in the turbine to cool vulnerable components. Wheel-spaces are formed between adjacent rotating and stationary discs, with purge air supplied at low radius before exiting into the mainstream gas-path through a rim-seal at the disc periphery. An aerodynamic penalty is incurred as the purge flow egress interacts with the mainstream. This study presents unparalleled three-dimensional velocity data from a single-stage turbine test rig, specifically designed to investigate egress–mainstream interaction using optical measurement techniques. Volumetric velocimetry is applied to the rotating environment with phase-locked measurements used to identify and track the vortical secondary flow features through the blade passage. A baseline case without purge flow is compared to experiments with a 1.7% purge mass fraction; the latter was chosen to ensure a fully sealed wheel-space. A non-localized vortex tracking function is applied to the data to identify the position of the core centroids. The strength of the secondary flow vortices was determined using a circulation criterion on rotated planes aligned to the vortex filaments. The pressure-side leg of the horseshoe vortex and a second vortex associated with the egress flow were identified by the experimental campaign. In the absence of purge flow, the two vortices merged, forming the passage vortex (PV). With the addition of purge flow, the two cores remained independent to 40% of the blade axial chord, while also demonstrating an increased radial migration and intensification of the PV. The egress core was shown to remain closer to the suction-surface with purge flow. Importantly, where the vortex filaments demonstrated strong radial or tangential components of velocity, the circulation level calculated from axial planes underpredicted the true circulation by up to 50%.
- Open Access
- 16 July 2021
- Published by ASME International
Conditioning of Leakage Flows in Gas Turbine Rotor-Stator Cavities
Hot gas ingress can occur in gas turbines, where mainstream fluid enters the cavity formed between the turbine disc (rotor) and its adjacent casing (stator). A rim seal is fitted at the periphery of the discs and a superposed sealant flow – typically fed through the bore of the stator - is used to reduce, or in the limit prevent, ingress. Parasitic leakage flows pass through
- 16 July 2021
- Published by ASME International
Open AccessConditioning of Leakage Flows in Gas Turbine Rotor-Stator Cavities
Hot gas ingress can occur in gas turbines, where mainstream fluid enters the cavity formed between the turbine disc (rotor) and its adjacent casing (stator). A rim seal is fitted at the periphery of the discs and a superposed sealant flow – typically fed through the bore of the stator - is used to reduce, or in the limit prevent, ingress. Parasitic leakage flows pass through
- Open Access
- 16 July 2021
- Published by ASME International
Volumetric Velocimetry Measurements of Purge-Mainstream Interaction in a 1-Stage Turbine
Air-cooled gas turbines employ bleed air from the compressor to cool vulnerable components in the turbine. The cooling flow, commonly known as *purge air*, is introduced at low radius, before exiting through the rim-seal at the periphery of the turbine discs. The purge flow interacts with the mainstream gas path, creating an unsteady and complex flow-field. Of particular interest
- 16 July 2021
- Published by ASME International
Open AccessVolumetric Velocimetry Measurements of Purge-Mainstream Interaction in a 1-Stage Turbine
Air-cooled gas turbines employ bleed air from the compressor to cool vulnerable components in the turbine. The cooling flow, commonly known as *purge air*, is introduced at low radius, before exiting through the rim-seal at the periphery of the turbine discs. The purge flow interacts with the mainstream gas path, creating an unsteady and complex flow-field. Of particular interest
- 24 March 2021
- Published by Wiley in Journal of Turbomachinery
- Vol. 143 (4)
Volumetric Velocimetry Measurements of Purge–Mainstream Interaction in a One-Stage Turbine
Air-cooled gas turbines employ bleed air from the compressor to cool vulnerable components in the turbine. The cooling flow, commonly known as purge air, is introduced at low radius, before exiting through the rim-seal at the periphery of the turbine discs. The purge flow interacts with the mainstream gas path, creating an unsteady and complex flowfield. Of particular interest to the designer is the effect of purge on the secondary-flow structures within the blade passage, the extent of which directly affects the aerodynamic loss in the stage. This paper presents a combined experimental and computational fluid dynamics (CFD) investigation into the effect of purge flow on the secondary flows in the blade passage of an optically accessible one-stage turbine rig. The experimental campaign was conducted using volumetric velocimetry (VV) measurements to assess the three-dimensional inter-blade velocity field; the complementary CFD campaign was carried out using unsteady Reynolds-averaged Navier–Stokes (URANS) computations. The implementation of VV within a rotating environment is a world first and offers an unparalleled level of experimental detail. The baseline flow-field, in the absence of purge flow, demonstrated a classical secondary flow-field: the rollup of a horseshoe vortex, with subsequent downstream convection of a pressure-side and suction-side leg, the former transitioning in to the passage vortex. The introduction of purge, at 1.7% of the mainstream flowrate, was shown to modify the secondary flow-field by enhancing the passage vortex, in both strength and span-wise migration. The computational predictions were in agreement with the enhancement revealed by the experiments.
- 24 March 2021
- Published by Wiley in Journal of Turbomachinery
- Vol. 143 (4)
Volumetric Velocimetry Measurements of Purge–Mainstream Interaction in a One-Stage Turbine
Air-cooled gas turbines employ bleed air from the compressor to cool vulnerable components in the turbine. The cooling flow, commonly known as purge air, is introduced at low radius, before exiting through the rim-seal at the periphery of the turbine discs. The purge flow interacts with the mainstream gas path, creating an unsteady and complex flowfield. Of particular interest to the designer is the effect of purge on the secondary-flow structures within the blade passage, the extent of which directly affects the aerodynamic loss in the stage. This paper presents a combined experimental and computational fluid dynamics (CFD) investigation into the effect of purge flow on the secondary flows in the blade passage of an optically accessible one-stage turbine rig. The experimental campaign was conducted using volumetric velocimetry (VV) measurements to assess the three-dimensional inter-blade velocity field; the complementary CFD campaign was carried out using unsteady Reynolds-averaged Navier–Stokes (URANS) computations. The implementation of VV within a rotating environment is a world first and offers an unparalleled level of experimental detail. The baseline flow-field, in the absence of purge flow, demonstrated a classical secondary flow-field: the rollup of a horseshoe vortex, with subsequent downstream convection of a pressure-side and suction-side leg, the former transitioning in to the passage vortex. The introduction of purge, at 1.7% of the mainstream flowrate, was shown to modify the secondary flow-field by enhancing the passage vortex, in both strength and span-wise migration. The computational predictions were in agreement with the enhancement revealed by the experiments.
- 18 January 2021
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 143 (2)
Conditioning of Leakage Flows in Gas Turbine Rotor–Stator Cavities
Ingress is the penetration of hot mainstream fluid into the cavity formed between the turbine disk (rotor) and its adjacent casing (stator). Gas turbine engine designers use rim-seals fitted at the periphery of the disks, and a superposed sealant flow—typically fed through the bore of the stator—is used to reduce, or in the limit prevent, ingress. Parasitic leakage enters the cavity through pathways created between mating interfaces of engine components. Owing to the aggressive thermal and centrifugal loading experienced during the turbine operating cycle, the degree of leakage and its effect on ingress are difficult to predict. This paper considers the potential for leakage flows to be conditioned in order to minimize their parasitic effect on disk cooling, and ultimately engine, performance. Measurements of static and total pressure, swirl, and species concentration were used to assess the performance of a simple axial clearance rim-seal over a range of nondimensional leakage flow rates. A computational model was used to provide flow visualization to support the interpretation of flow structures derived from the experiments. Data are presented to investigate the effects of swirling the leakage flow in accordance with, and counter to, the disk rotation. The injected momentum from the leakage created a toroidal vortex in the outer part of the cavity. Coswirl was found to improve the sealing effectiveness by up to 15% compared to the axially introduced baseline and counterswirled configurations. Varying the momentum of the leakage flow was considered by passing consistent mass-flows through a range of leakage outlet areas. Increasing the momentum was seen to increase the influence of the toroidal vortex on the flow structure in the cavity, which in turn influenced the sealing effectiveness.
- 18 January 2021
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 143 (2)
Conditioning of Leakage Flows in Gas Turbine Rotor–Stator Cavities
Ingress is the penetration of hot mainstream fluid into the cavity formed between the turbine disk (rotor) and its adjacent casing (stator). Gas turbine engine designers use rim-seals fitted at the periphery of the disks, and a superposed sealant flow—typically fed through the bore of the stator—is used to reduce, or in the limit prevent, ingress. Parasitic leakage enters the cavity through pathways created between mating interfaces of engine components. Owing to the aggressive thermal and centrifugal loading experienced during the turbine operating cycle, the degree of leakage and its effect on ingress are difficult to predict. This paper considers the potential for leakage flows to be conditioned in order to minimize their parasitic effect on disk cooling, and ultimately engine, performance. Measurements of static and total pressure, swirl, and species concentration were used to assess the performance of a simple axial clearance rim-seal over a range of nondimensional leakage flow rates. A computational model was used to provide flow visualization to support the interpretation of flow structures derived from the experiments. Data are presented to investigate the effects of swirling the leakage flow in accordance with, and counter to, the disk rotation. The injected momentum from the leakage created a toroidal vortex in the outer part of the cavity. Coswirl was found to improve the sealing effectiveness by up to 15% compared to the axially introduced baseline and counterswirled configurations. Varying the momentum of the leakage flow was considered by passing consistent mass-flows through a range of leakage outlet areas. Increasing the momentum was seen to increase the influence of the toroidal vortex on the flow structure in the cavity, which in turn influenced the sealing effectiveness.