AHAhmed Hafez

Ahmed Hafez

*This is an algorithmically generated author record based on publicly available information.

Ahmed Hafez has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • JoVE Video Dataset

    by Asma Alahmadi, Yassin Abdelsamad, Ahmed Hafez, Medhat Yousef, Fida Almuhawas, Abdulrahman Hagr

    This study presents a protocol for applying X-ray-guided anatomy-based fitting (ABF) in cochlear implant (CI) programming to reduce frequency-to-place mismatch. The goal is to improve alignment between the frequencies stimulated by each electrode and the natural tonotopic organization of the cochlea, thereby enhancing speech perception and auditory outcomes. Traditional default fitting (DF) methods don't account for individual variations in cochlear anatomy, leading to mismatches that can influence performance. In this prospective study, 16 ears from 12 CI users with normal cochlear anatomy were assessed using X-ray imaging to estimate angular insertion depth (AID) and guide the ABF protocol. Frequency assignments for each electrode were adjusted using OTOPLAN and MAESTRO software to match the cochlea's tonotopic map. Results showed that ABF significantly reduced the average frequency-to-place mismatch (2.6 ± 3.8 semitones) compared to DF (6.6 ± 5.6 semitones). ABF also showed a stronger correlation between AID and frequency shifts, with the most notable improvements in the mid-cochlear region. This protocol applies a low-radiation, accessible alternative to CT-guided ABF, particularly beneficial for pediatric or radiation-sensitive populations. X-ray-guided ABF demonstrates potential for more accurate CI programming and the potential to improve patient outcomes. Further studies with larger cohorts and longer follow-up periods are recommended to validate its clinical benefits.

  • Cochlear Implantation: First Experience with X-Ray Guided Anatomy-Based Fitting

    by Asma Alahmadi, Yassin Abdelsamad, Ahmed Hafez, Medhat Yousef, Fida Almuhawas, Abdulrahman Hagr

    This study presents a protocol for applying X-ray-guided anatomy-based fitting (ABF) in cochlear implant (CI) programming to reduce frequency-to-place mismatch. The goal is to improve alignment between the frequencies stimulated by each electrode and the natural tonotopic organization of the cochlea, thereby enhancing speech perception and auditory outcomes. Traditional default fitting (DF) methods don't account for individual variations in cochlear anatomy, leading to mismatches that can influence performance. In this prospective study, 16 ears from 12 CI users with normal cochlear anatomy were assessed using X-ray imaging to estimate angular insertion depth (AID) and guide the ABF protocol. Frequency assignments for each electrode were adjusted using OTOPLAN and MAESTRO software to match the cochlea's tonotopic map. Results showed that ABF significantly reduced the average frequency-to-place mismatch (2.6 ± 3.8 semitones) compared to DF (6.6 ± 5.6 semitones). ABF also showed a stronger correlation between AID and frequency shifts, with the most notable improvements in the mid-cochlear region. This protocol applies a low-radiation, accessible alternative to CT-guided ABF, particularly beneficial for pediatric or radiation-sensitive populations. X-ray-guided ABF demonstrates potential for more accurate CI programming and the potential to improve patient outcomes. Further studies with larger cohorts and longer follow-up periods are recommended to validate its clinical benefits.


  • Open Access

    Electric Auditory Brainstem Response Audiometry in Cochlear Implants: New Recording Paradigm

    by Takwa Gabr, Hossam Debis, Ahmed Hafez

    (1) Background: Cochlear implants (CIs) are widely applied to recover audition for patients with severe degrees of or total hearing loss. Electrical stimulation using the electrically evoked ABR (E-ABR) can be recorded in CI recipients through the device. This work was designed to study E-ABR recorded individually from different channels located at the apical, middle, and basal cochlear regions in comparison to their simultaneous separated or adjacent combined recordings. (2) Methods: This study included 17 children fitted with unilateral cochlear implants. All children were subjected to impedance measurement, electrical compound action potentials (ECAP), and E-ABR recording of three channels located at the apical, middle, and basal cochlear regions. This was followed by simultaneous E-ABR recording of the three “separated” channels in comparison to E-ABR recording from three adjacent channels located at the middle cochlear region. (3) Results: Similar E-ABR latencies and amplitudes were found using either individual or simultaneously separated or adjacent combined recording. However, the mean amplitude measures of E-ABR for combined adjacent channels showed a positive correlation with the applied current level. (4) Conclusions: Combined E-ABR recording from adjacent channels is a faster and more reliable technique that can be used effectively without compromising the results of the recorded E-ABR.


  • Open Access

    Cochlear Implantation: Long-Term Effect of Early Activation on Electrode Impedance

    by Asma Alahmadi, Yassin Abdelsamad, Medhat Yousef, Fida Almuhawas, Ahmed Hafez, Farid Alzhrani, Abdulrahman Hagr

    Objectives: The growing adoption of cochlear implants (CIs) necessitates understanding the factors influencing long-term performance and improved outcomes. This work investigated the long-term effect of early activation of CIs on electrode impedance in a large sample of CI users at different time points. Methods: A retrospective study on 915 ears from CI patients who were implanted between 2015 and 2020. According to their CI audio processor activation time, the patients were categorized into early activation (activated 1 day after surgery, n = 481) and classical activation (activated 4 weeks after surgery, n = 434) groups. Then, the impact of the activation times on the electrode impedance values, along the electrode array contacts, at different time points up to two years was studied and analyzed. Results: The early activation group demonstrated lower impedance values across all the electrode array sections compared to the classical activation at 1 month, 1 year, and 2 years post-implantation. At 1 month, early activation was associated with a reduction of 0.34 kΩ, 0.46 kΩ, and 0.37 kΩ in the apical, middle, and basal sections, respectively. These differences persisted at subsequent intervals. Conclusions: Early activation leads to sustained reductions in the electrode impedance compared to classical activation (CA), suggesting that earlier activation might positively affect long-term CI outcomes.