Jiting Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiting Liu has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Qijia Shao
The Hong Kong University of Science and Technology, Hong Kong Sar, China
5 shared publications - Ho Man Colman Leung
Department of Computer Science, Columbia University, New York, NY, USA
3 shared publications - Xia Zhou
Computer Science, Columbia University, New York, New York, USA
3 shared publications - Xiaofan Jiang
Columbia University, New York, New York, USA
3 shared publications - Emily Bejerano
Columbia University, New York, New York, USA
2 shared publications - Guangtao Xue
Shanghai Jiao Tong University, Shanghai, China
2 shared publications
Latest Publications
- Open Access
- 26 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 690-705
SwimHR: Wearable-Free Heart Rate Monitoring for Swimmers via Water-Mediated ECG Sensing
Heart rate (HR) monitoring during swimming is crucial for athlete performance optimization and physiological assessment. Yet existing solutions remain unsatisfactory. ECG chest straps require tight skin contact and are often uncomfortable during swimming, while photoplethysmography (PPG) sensors suffer severe accuracy degradation due to swimming-induced motion artifacts. We present SwimHR, the first wearable-free HR monitoring system that captures electrocardiogram (ECG) signals transmitted through pool water without any on-body device. To enable practical pool-scale underwater ECG sensing, we (1) derive and validate a physical model of ECG transmission in water and quantify environmental attenuation in swimming pools through simulation, (2) design a lane-scale sensing architecture with a bias-electrode-free acquisition circuit for reliable full-lane coverage, and (3) develop a U-Net-based pipeline for robust R-peak detection under stroke-dependent swimming artifacts. We evaluate SwimHR with 34 swimmers (12 amateur and 22 professional) across four strokes and multiple pools. SwimHR achieves a mean HR error of 1.0 bpm with a standard deviation of 0.9 bpm relative to the ECG ground truth, significantly outperforming PPG-based wearables. SwimHR demonstrates the feasibility of accurate, real-time, wearable-free HR monitoring in standard swimming pool settings while avoiding the discomfort of body-worn sensors.
- 26 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 690-705
Open AccessSwimHR: Wearable-Free Heart Rate Monitoring for Swimmers via Water-Mediated ECG Sensing
Heart rate (HR) monitoring during swimming is crucial for athlete performance optimization and physiological assessment. Yet existing solutions remain unsatisfactory. ECG chest straps require tight skin contact and are often uncomfortable during swimming, while photoplethysmography (PPG) sensors suffer severe accuracy degradation due to swimming-induced motion artifacts. We present SwimHR, the first wearable-free HR monitoring system that captures electrocardiogram (ECG) signals transmitted through pool water without any on-body device. To enable practical pool-scale underwater ECG sensing, we (1) derive and validate a physical model of ECG transmission in water and quantify environmental attenuation in swimming pools through simulation, (2) design a lane-scale sensing architecture with a bias-electrode-free acquisition circuit for reliable full-lane coverage, and (3) develop a U-Net-based pipeline for robust R-peak detection under stroke-dependent swimming artifacts. We evaluate SwimHR with 34 swimmers (12 amateur and 22 professional) across four strokes and multiple pools. SwimHR achieves a mean HR error of 1.0 bpm with a standard deviation of 0.9 bpm relative to the ECG ground truth, significantly outperforming PPG-based wearables. SwimHR demonstrates the feasibility of accurate, real-time, wearable-free HR monitoring in standard swimming pool settings while avoiding the discomfort of body-worn sensors.
- Open Access
- 26 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 1780-1782
Demo: Can Water Carry Your ECG? An Interactive Demonstration of SwimHR
- 26 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 1780-1782
Open AccessDemo: Can Water Carry Your ECG? An Interactive Demonstration of SwimHR
- Open Access
- 3 November 2025
- Published by Association for Computing Machinery (ACM)
- p. 283-298
CGMM: Non-Invasive Continuous Glucose Monitoring in Wearables Using Metasurfaces
- 3 November 2025
- Published by Association for Computing Machinery (ACM)
- p. 283-298
Open AccessCGMM: Non-Invasive Continuous Glucose Monitoring in Wearables Using Metasurfaces
- Open Access
- 3 September 2025
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 9 (3) , 1-26
My Pillow Knows My Sleep: Sleep Monitoring with Computational Fabrics in the Pillowcase
Sleep is a vital physiological state that significantly impacts overall health. Continuous monitoring of sleep posture, heart rate, respiratory rate, and body movement is crucial for diagnosing and managing sleep disorders. Current monitoring solutions often disrupt natural sleep due to discomfort or raise privacy and instrumentation concerns. We introduce PillowSense, a fabric-based sleep monitoring system seamlessly integrated into a pillowcase. PillowSense utilizes a dual-layer fabric design. The top layer comprises conductive fabrics for sensing electrocardiogram (ECG) and surface electromyogram (sEMG), while the bottom layer features pressure-sensitive fabrics to monitor sleep location and movement. The system processes ECG and sEMG signals sequentially to infer multiple sleep variables and incorporates an adversarial neural network to enhance posture classification accuracy. We fabricate prototypes using off-the-shelf hardware and conduct both lab-based and in-the-wild longitudinal user studies to evaluate the system's effectiveness. Across 151 nights and 912.2 hours of real-world sleep data, the system achieves an F1 score of 88% for classifying seven sleep postures, and clinically-acceptable accuracy in vital sign monitoring. PillowSense's comfort, washability, and robustness in multi-user scenarios underscore its potential for unobtrusive, large-scale sleep monitoring.
- 3 September 2025
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 9 (3) , 1-26
Open AccessMy Pillow Knows My Sleep: Sleep Monitoring with Computational Fabrics in the Pillowcase
Sleep is a vital physiological state that significantly impacts overall health. Continuous monitoring of sleep posture, heart rate, respiratory rate, and body movement is crucial for diagnosing and managing sleep disorders. Current monitoring solutions often disrupt natural sleep due to discomfort or raise privacy and instrumentation concerns. We introduce PillowSense, a fabric-based sleep monitoring system seamlessly integrated into a pillowcase. PillowSense utilizes a dual-layer fabric design. The top layer comprises conductive fabrics for sensing electrocardiogram (ECG) and surface electromyogram (sEMG), while the bottom layer features pressure-sensitive fabrics to monitor sleep location and movement. The system processes ECG and sEMG signals sequentially to infer multiple sleep variables and incorporates an adversarial neural network to enhance posture classification accuracy. We fabricate prototypes using off-the-shelf hardware and conduct both lab-based and in-the-wild longitudinal user studies to evaluate the system's effectiveness. Across 151 nights and 912.2 hours of real-world sleep data, the system achieves an F1 score of 88% for classifying seven sleep postures, and clinically-acceptable accuracy in vital sign monitoring. PillowSense's comfort, washability, and robustness in multi-user scenarios underscore its potential for unobtrusive, large-scale sleep monitoring.
- Open Access
- 4 December 2024
- Published by Association for Computing Machinery (ACM)
- p. 1424-1438
GPMS: Enabling Indoor GNSS Positioning using Passive Metasurfaces
Global Navigation Satellite System (GNSS) is extensively utilized for outdoor positioning and navigation. However, achieving high-precision indoor positioning is challenging due to the significant attenuation of GNSS signals indoors. To address this issue, we propose an innovative indoor GNSS positioning system called GPMS, which uses passive metasurface technology to redirect GNSS signals from outdoors into indoor spaces. These passive metasurfaces are strategically optimized for indoor coverage by steering and scattering the GNSS signals across a wide range of incident angles. We further develop a novel localization algorithm that can determine which metasurface the signal goes through and localize the user using the set of metasurfaces as anchor points. A distinct advantage of our localization algorithm is that it can be implemented on existing mobile devices without any hardware modifications. We implement the prototype of GPMS, and deploy six metasurfaces in two indoor environments, a 10×50 m2 office floor and a 15×20 m2 lecture room, to evaluate system performance. In terms of coverage, our GPMS increases the C/N0 from 9.1 dB-Hz to 23.2 dB-Hz and increases the number of visible satellites from 3.6 to 21.5 in the office floor. In terms of indoor positioning accuracy, our proposed system decreases the absolute positioning error from 30.6 m to 3.2 m in the office floor, and from 11.2 m to 2.7 m in the lecture room, demonstrating the feasibility and benefits of metasurface-assisted GNSS for indoor positioning.
- 4 December 2024
- Published by Association for Computing Machinery (ACM)
- p. 1424-1438
Open AccessGPMS: Enabling Indoor GNSS Positioning using Passive Metasurfaces
Global Navigation Satellite System (GNSS) is extensively utilized for outdoor positioning and navigation. However, achieving high-precision indoor positioning is challenging due to the significant attenuation of GNSS signals indoors. To address this issue, we propose an innovative indoor GNSS positioning system called GPMS, which uses passive metasurface technology to redirect GNSS signals from outdoors into indoor spaces. These passive metasurfaces are strategically optimized for indoor coverage by steering and scattering the GNSS signals across a wide range of incident angles. We further develop a novel localization algorithm that can determine which metasurface the signal goes through and localize the user using the set of metasurfaces as anchor points. A distinct advantage of our localization algorithm is that it can be implemented on existing mobile devices without any hardware modifications. We implement the prototype of GPMS, and deploy six metasurfaces in two indoor environments, a 10×50 m2 office floor and a 15×20 m2 lecture room, to evaluate system performance. In terms of coverage, our GPMS increases the C/N0 from 9.1 dB-Hz to 23.2 dB-Hz and increases the number of visible satellites from 3.6 to 21.5 in the office floor. In terms of indoor positioning accuracy, our proposed system decreases the absolute positioning error from 30.6 m to 3.2 m in the office floor, and from 11.2 m to 2.7 m in the lecture room, demonstrating the feasibility and benefits of metasurface-assisted GNSS for indoor positioning.
- Open Access
- 3 June 2024
- Published by Association for Computing Machinery (ACM)
- p. 237-251
Joey: Supporting Kangaroo Mother Care with Computational Fabrics
Kangaroo Mother Care (KMC), involving chest-to-chest skin contact between an infant and caregiver, is proven to be an effective intervention for preterm and full-term infants. Accurate monitoring of KMC duration and infant's vital signs during KMC is clinically important. Existing monitoring methods, however, rely on manual efforts and require rigid sensors or wires/electrodes on the infant's body. We propose Joey, a fabric-based approach to continuously monitor KMC duration and two vital signs essential to an infant's well-being: heart rate and respiration rate. Joey is a soft fabric necklace worn by the caregiver. It leverages the transmission of electrocardiogram (ECG) signals across individuals during skin-to-skin contact. With a minimalist fabric sensor structure, Joey measures KMC duration via the presence of mixed ECG signals. It then isolates the infant's ECG from this mixture with a proposed signal extraction algorithm and employs a diffusion-based denoising model to mitigate motion artifacts, enabling reliable inference of infant's vital signs. We fabricate Joey prototypes with off-the-shelf hardware and evaluate its performance with user studies. Results demonstrate that Joey achieves an average F1 score of 96% for KMC duration measurement, and clinically-acceptable accuracy in infant's vital sign estimation with a mean absolute error of 2.3 beats per minute and 2.9 breaths per minute in estimating heart rate and respiration rate. Clinical interviews further confirm the usability of Joey's sensing fabric for infant skin. A demonstration video of Joey is available at: mobilex.cs.columbia.edu/joey
- 3 June 2024
- Published by Association for Computing Machinery (ACM)
- p. 237-251
Open AccessJoey: Supporting Kangaroo Mother Care with Computational Fabrics
Kangaroo Mother Care (KMC), involving chest-to-chest skin contact between an infant and caregiver, is proven to be an effective intervention for preterm and full-term infants. Accurate monitoring of KMC duration and infant's vital signs during KMC is clinically important. Existing monitoring methods, however, rely on manual efforts and require rigid sensors or wires/electrodes on the infant's body. We propose Joey, a fabric-based approach to continuously monitor KMC duration and two vital signs essential to an infant's well-being: heart rate and respiration rate. Joey is a soft fabric necklace worn by the caregiver. It leverages the transmission of electrocardiogram (ECG) signals across individuals during skin-to-skin contact. With a minimalist fabric sensor structure, Joey measures KMC duration via the presence of mixed ECG signals. It then isolates the infant's ECG from this mixture with a proposed signal extraction algorithm and employs a diffusion-based denoising model to mitigate motion artifacts, enabling reliable inference of infant's vital signs. We fabricate Joey prototypes with off-the-shelf hardware and evaluate its performance with user studies. Results demonstrate that Joey achieves an average F1 score of 96% for KMC duration measurement, and clinically-acceptable accuracy in infant's vital sign estimation with a mean absolute error of 2.3 beats per minute and 2.9 breaths per minute in estimating heart rate and respiration rate. Clinical interviews further confirm the usability of Joey's sensing fabric for infant skin. A demonstration video of Joey is available at: mobilex.cs.columbia.edu/joey
- Open Access
- 3 June 2024
- Published by Association for Computing Machinery (ACM)
- p. 602-603
Demo: Supporting Kangaroo Mother Care with Computational Fabrics
Kangaroo Mother Care (KMC), involving chest-to-chest skin contact between an infant and caregiver, is proven to be an effective intervention for preterm and full-term infants. Accurate monitoring of KMC duration and infant's vital signs during KMC is clinically important. Existing monitoring methods, however, rely on manual efforts and require rigid sensors or wires/electrodes on the infant's body. We propose Joey, a fabric-based approach to continuously monitor KMC duration and two vital signs essential to an infant's well-being: heart rate and respiration rate. Joey is a soft fabric necklace worn by the caregiver. It leverages the transmission of electrocardiogram (ECG) signals across individuals during skin-to-skin contact. With a minimalist fabric sensor structure, Joey measures KMC duration via the presence of mixed ECG signals. It then isolates the infant's ECG from this mixture with a proposed signal extraction algorithm and employs a diffusion-based denoising model to mitigate motion artifacts, enabling reliable inference of the infant's vital signs. We demonstrate Joey's sensing capability with hand-shaking experiments, showing the real-time mixed ECGs. A demonstration video of Joey for actual KMC practice is available at: mobilex.cs.columbia.edu/joey
- 3 June 2024
- Published by Association for Computing Machinery (ACM)
- p. 602-603
Open AccessDemo: Supporting Kangaroo Mother Care with Computational Fabrics
Kangaroo Mother Care (KMC), involving chest-to-chest skin contact between an infant and caregiver, is proven to be an effective intervention for preterm and full-term infants. Accurate monitoring of KMC duration and infant's vital signs during KMC is clinically important. Existing monitoring methods, however, rely on manual efforts and require rigid sensors or wires/electrodes on the infant's body. We propose Joey, a fabric-based approach to continuously monitor KMC duration and two vital signs essential to an infant's well-being: heart rate and respiration rate. Joey is a soft fabric necklace worn by the caregiver. It leverages the transmission of electrocardiogram (ECG) signals across individuals during skin-to-skin contact. With a minimalist fabric sensor structure, Joey measures KMC duration via the presence of mixed ECG signals. It then isolates the infant's ECG from this mixture with a proposed signal extraction algorithm and employs a diffusion-based denoising model to mitigate motion artifacts, enabling reliable inference of the infant's vital signs. We demonstrate Joey's sensing capability with hand-shaking experiments, showing the real-time mixed ECGs. A demonstration video of Joey for actual KMC practice is available at: mobilex.cs.columbia.edu/joey