MHMonica Catalina Huerta-Sanchez

Monica Catalina Huerta-Sanchez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Monica Catalina Huerta-Sanchez has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparative Analysis of PSMA PET-CT: Assessing Prostate Cancer Activity without CT Findings

    by Luis Adrian Alvarez-Lozada, Ethel Valeria Orta-Guerra, Mónica Catalina Huerta-Sánchez, Diego Escamilla-Magaña, Miguel Emmanuel Navarrete-Juárez, Alejandro Quiroga-Garza, Rodrigo Enrique Elizondo-Omaña, Santos Gúzman-López, Guillermo Elizondo-Riojas

  • Underdiagnosis of umbilical hernias in CT scans in a multicenter study – the radiologically neglected pathology and its surgical implications

    by Luis Adrian Alvarez-Lozada, Francisco Javier Arrambide-Garza, Alejandro Quiroga-Garza, Monica Catalina Huerta-Sanchez, Ana Escobar-Luna, Miguel Antonio Sada-Treviño, Carlos Enrique Ramos-Proaño, Rodrigo Enrique Elizondo-Omaña

    Purpose Umbilical hernias (UH) have a higher prevalence than previously considered. With the high workload radiologists must endure, UH can be missed when interpreting a computed tomography scan (CT). The clinical implications of its misdiagnosis are yet to be determined. Unreporting could lead to content lesions in surgical approaches and other potential complications. The aim was to determine the prevalence of UH using CT scans, and the incidence of radiological reporting. Methods A multicenter, cross-sectional study was performed in four tertiary-level hospitals. CT scans were reviewed for abdominal wall defects at the umbilicus, and radiological reports were examined to compare findings. In the case of UH, transversal, anteroposterior, and craniocaudal lengths were obtained. Results A total of 1557 CTs were included, from which 971 (62.4%, 95% CI 0.59–0.64) had UH. Out of those, 629 (64.8%, 95% CI 0.61–0.67) of the defects were not included in the radiological report. Smaller UH (x̄: 7.7 × 6.0 mm) were more frequently missed. Of the reported UH, 187 (54.7%) included at least one axis measurement, 289 (84.5%) content description, and 146 (42.7%) whether or not there were complication signs. Conclusion There is a high prevalence of UH, and a high incidence of under-reporting. This raises the question of whether this is a population-based finding or the norm worldwide. The reason of under-reporting and the clinical implications of these must be addressed in further studies.