Mohammad Hassan Kharita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mohammad Hassan Kharita has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed Omar
Clinical Imaging Department, Hamad General Hospital , PO Box 3050, Doha , Qatar
1 shared publication - Alaa Abd Al-Rahim
Hamad Medical Corporation
1 shared publication - Amer Ghujeh
Hamad Medical Corporation
1 shared publication - Hadi Fayad
Hamad Medical Corporation, Doha, Qatar
1 shared publication - Huda AlNaemi
Medical Physics Section , OHS Department PO Box 3050, Doha , Qatar
1 shared publication - Ioannis A. Tsalafoutas
Medical Physics Section OHS Department Hamad Medical Corporation Doha Qatar
1 shared publication
Latest Publications
- 2 August 2026
- Published by Springer Nature
- p. 690-704
AI-Driven PET Attenuation Correction: Eliminating the Need for CT
- 2 August 2026
- Published by Springer Nature
- p. 690-704
AI-Driven PET Attenuation Correction: Eliminating the Need for CT
- Open Access
- 21 June 2023
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (12) , 1301-1309
Patient exposure during videofluoroscopic swallowing studies performed by speech-language pathologists
Videofluoroscopic swallowing studies (VFSSs) are fluoroscopic examinations performed by speech and language pathologists (SLPs), for the evaluation of the oral and pharyngeal phases of swallowing, in patients who are diagnosed with symptoms like dysphagia and speech impairment. The study was focused on the evaluation of the patient doses from VFSS performed at Hamad Medical Corporation hospitals. Data on the patient exposure and examination parameters were extracted from the Radiation Dose Monitoring system, statistically analysed and compared with literature. For adult patients, the mean (median) values for fluoroscopy time and kerma-air product were 2.8 (2.7) min and 181 (144) cGycm2, respectively. For children, the respective mean (median) values were 2.6 (2.4) min and 15.3 (9.2) cGycm2. The results of the study indicate that the VFSS are performed by well-trained health professionals, and as a result, image quality sufficient for a confident diagnosis is obtained at relatively low dose levels.
- 21 June 2023
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (12) , 1301-1309
Open AccessPatient exposure during videofluoroscopic swallowing studies performed by speech-language pathologists
Videofluoroscopic swallowing studies (VFSSs) are fluoroscopic examinations performed by speech and language pathologists (SLPs), for the evaluation of the oral and pharyngeal phases of swallowing, in patients who are diagnosed with symptoms like dysphagia and speech impairment. The study was focused on the evaluation of the patient doses from VFSS performed at Hamad Medical Corporation hospitals. Data on the patient exposure and examination parameters were extracted from the Radiation Dose Monitoring system, statistically analysed and compared with literature. For adult patients, the mean (median) values for fluoroscopy time and kerma-air product were 2.8 (2.7) min and 181 (144) cGycm2, respectively. For children, the respective mean (median) values were 2.6 (2.4) min and 15.3 (9.2) cGycm2. The results of the study indicate that the VFSS are performed by well-trained health professionals, and as a result, image quality sufficient for a confident diagnosis is obtained at relatively low dose levels.