Zhengbo Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhengbo Li has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Chongyang Huang
1 shared publication- Chongyang Huang
Key Laboratory of Special Machines and High Voltage Apparatus, School of Electrical Engineering, Shenyang University of Technology, Shenyang, China
1 shared publication Chongyang黄翀Huang阳
Key Lab of Special Electric Machine and High Voltage Apparatus, School of Electrical Engineering, Shenyang University of Technology
1 shared publication- Jing Li
Key Laboratory of Special Machines and High Voltage Apparatus, School of Electrical Engineering, Shenyang University of Technology, Shenyang, China
1 shared publication Jingbo苏敬Su博
Key Lab of Special Electric Machine and High Voltage Apparatus, School of Electrical Engineering, Shenyang University of Technology
1 shared publicationJing李Li静
Key Lab of Special Electric Machine and High Voltage Apparatus, School of Electrical Engineering, Shenyang University of Technology
1 shared publication
Latest Publications
- 25 September 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (38) , 385206
Effect of a magnetically blown arc on cumulative electrical erosion of contacts
Cumulative electrical erosion during repeated interruption is a key factor limiting the service lifetime of low-voltage direct current switching devices. In this work, the cumulative erosion behavior of air-switch contacts under magnetically blown arcs was investigated through experiments and numerical simulations. The effects of arc-root migration on molten-pool evolution, surface morphology, and the erosion resistance of Cu–Ni contacts were analyzed. An arc erosion experimental platform was established to perform repeated interruption tests under different magnetic flux densities, and a dynamic cumulative erosion model with a moving heat source was developed. The results show that the transverse magnetic field drives directional arc migration through the Lorentz force, resulting in continuous heating in the leading region and rapid solidification in the trailing region of the contact molten pool. This leads to significant asymmetries in the flow characteristics, force states, and splashing behavior of the molten metal. Compared with stationary heat-source erosion, the crater depth decreases by 25.8%, while the width increases by 12.5%, exhibiting an overall ‘bowl-shaped’ morphology. After repeated interruptions, the initial crater and resolidified layer modify the local thermal boundary conditions, promoting molten-pool spreading, which results in increases in crater width and depth by approximately 12% and 13.2%, respectively. Meanwhile, groove and step-like accumulated structures gradually form along the magnetic blow direction, further aggravating local electrical erosion. Simulations of Cu–Ni contacts indicate that 10% Ni content effectively reduces crater dimensions and improves erosion resistance, whereas 30% Ni content causes heat localization, leading to an 86% increase in crater depth and deterioration of erosion resistance. These findings provide a theoretical basis for lifetime prediction, structural optimization, and material selection of air-switch contacts.
- 25 September 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (38) , 385206
Effect of a magnetically blown arc on cumulative electrical erosion of contacts
Cumulative electrical erosion during repeated interruption is a key factor limiting the service lifetime of low-voltage direct current switching devices. In this work, the cumulative erosion behavior of air-switch contacts under magnetically blown arcs was investigated through experiments and numerical simulations. The effects of arc-root migration on molten-pool evolution, surface morphology, and the erosion resistance of Cu–Ni contacts were analyzed. An arc erosion experimental platform was established to perform repeated interruption tests under different magnetic flux densities, and a dynamic cumulative erosion model with a moving heat source was developed. The results show that the transverse magnetic field drives directional arc migration through the Lorentz force, resulting in continuous heating in the leading region and rapid solidification in the trailing region of the contact molten pool. This leads to significant asymmetries in the flow characteristics, force states, and splashing behavior of the molten metal. Compared with stationary heat-source erosion, the crater depth decreases by 25.8%, while the width increases by 12.5%, exhibiting an overall ‘bowl-shaped’ morphology. After repeated interruptions, the initial crater and resolidified layer modify the local thermal boundary conditions, promoting molten-pool spreading, which results in increases in crater width and depth by approximately 12% and 13.2%, respectively. Meanwhile, groove and step-like accumulated structures gradually form along the magnetic blow direction, further aggravating local electrical erosion. Simulations of Cu–Ni contacts indicate that 10% Ni content effectively reduces crater dimensions and improves erosion resistance, whereas 30% Ni content causes heat localization, leading to an 86% increase in crater depth and deterioration of erosion resistance. These findings provide a theoretical basis for lifetime prediction, structural optimization, and material selection of air-switch contacts.
- 1 October 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (10)
Experimental and numerical study of metal droplet splashing effects on direct current air arc interruption
To investigate the interaction between metal droplet motion and arc plasma dynamics during direct current interruption, an improved bidirectionally coupled model is developed based on magnetohydrodynamic theory. By incorporating the volume force exerted by the metal droplet into the momentum conservation equation, the model enables dynamic feedback between the air arc flow field and the metal droplet trajectories. The influence of droplet splashing (DS)-under varying velocities and particle sizes-on the flow field distribution within the contact gap is analyzed, and the mechanism of flow field reconstruction induced by metal droplet motion is revealed. Simulation and experimental results demonstrate that DS typically occurs under conditions such as current oscillation, which induces localized vortices in the flow field and inhibits the directional motion of the arc. Furthermore, metal droplets with larger diameters and higher velocities cause more severe disturbances to the arc-induced flow field.
- 1 October 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (10)
Experimental and numerical study of metal droplet splashing effects on direct current air arc interruption
To investigate the interaction between metal droplet motion and arc plasma dynamics during direct current interruption, an improved bidirectionally coupled model is developed based on magnetohydrodynamic theory. By incorporating the volume force exerted by the metal droplet into the momentum conservation equation, the model enables dynamic feedback between the air arc flow field and the metal droplet trajectories. The influence of droplet splashing (DS)-under varying velocities and particle sizes-on the flow field distribution within the contact gap is analyzed, and the mechanism of flow field reconstruction induced by metal droplet motion is revealed. Simulation and experimental results demonstrate that DS typically occurs under conditions such as current oscillation, which induces localized vortices in the flow field and inhibits the directional motion of the arc. Furthermore, metal droplets with larger diameters and higher velocities cause more severe disturbances to the arc-induced flow field.
- Open Access
- 1 October 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (10)
Study of arc and magnetic field parameters under delayed breaking condition of DB-DC VCB
Taking the mechanical double-break DC vacuum circuit breaker (DB DC VCB) as the research object, the magnetic field and temperature field distribution between the breaks and the plasma characteristics under the working condition of gap difference caused by actuator dispersion are investigated to explore the difference in arc characteristics between the two breaks. Based on the system of Maxwell and magnetohydrodynamic (MHD) equations, a non-simultaneous breaking model of the DB DC VCB is established, and parameters such as magnetic flux density, plasma velocity, inter-contact pressure, and ion and electron temperatures are calculated. The simulation results show that the cathode surface field emission effect is stronger in the small gap break (delayed breaking break). Besides, in the small gap break, the arc temperature is higher, the rate of decrease of temperature is lower, the electron velocity is higher, the magnetic flux density is lower, the regulatory ability of the magnetic field is weaker, and the plasma diffusion speed is slower. In the arc ignition stage, the arc aggregation state duration of the small gap break is longer than that of the normal break, which means the arc in the small gap break gets diffused and arc energy dissipation becomes harder. Therefore, the arc energy density of the delayed breaking break is greater, the arc morphology transition time is longer, the residual particle concentration after arc extinguishing is higher, and the probability of re-strike breakdown increases with the increase in gap difference. Improving the synchronization of the actuator could improve the breaking ability of the DB DC VCB. Index terms—plasma arc, double-break direct current vacuum circuit breaker (DB-DC VCB), transverse magnetic field (TMF), magnetohydrodynamic (MHD) model.
- 1 October 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (10)
Open AccessStudy of arc and magnetic field parameters under delayed breaking condition of DB-DC VCB
Taking the mechanical double-break DC vacuum circuit breaker (DB DC VCB) as the research object, the magnetic field and temperature field distribution between the breaks and the plasma characteristics under the working condition of gap difference caused by actuator dispersion are investigated to explore the difference in arc characteristics between the two breaks. Based on the system of Maxwell and magnetohydrodynamic (MHD) equations, a non-simultaneous breaking model of the DB DC VCB is established, and parameters such as magnetic flux density, plasma velocity, inter-contact pressure, and ion and electron temperatures are calculated. The simulation results show that the cathode surface field emission effect is stronger in the small gap break (delayed breaking break). Besides, in the small gap break, the arc temperature is higher, the rate of decrease of temperature is lower, the electron velocity is higher, the magnetic flux density is lower, the regulatory ability of the magnetic field is weaker, and the plasma diffusion speed is slower. In the arc ignition stage, the arc aggregation state duration of the small gap break is longer than that of the normal break, which means the arc in the small gap break gets diffused and arc energy dissipation becomes harder. Therefore, the arc energy density of the delayed breaking break is greater, the arc morphology transition time is longer, the residual particle concentration after arc extinguishing is higher, and the probability of re-strike breakdown increases with the increase in gap difference. Improving the synchronization of the actuator could improve the breaking ability of the DB DC VCB. Index terms—plasma arc, double-break direct current vacuum circuit breaker (DB-DC VCB), transverse magnetic field (TMF), magnetohydrodynamic (MHD) model.
- Open Access
- 1 June 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (6)
Impact of contact rotation on the vacuum arc root movement
This paper aims to investigate the dynamic characteristics of vacuum metal vapor arcs under rotating and traditional direct contact separation modes. Non-symmetrical pure copper electrodes with an anode radius of 7.5 mm and a cathode radius of 22.5 mm are employed in the experiments. The permanent magnet actuator provides an average opening speed of 1.0 m/s for cathode direct separation and 1–3 deg/ms for rotation. Results show that electrode rotation significantly influences the distribution and motion speed of the arc root on the cathode surface.
- 1 June 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (6)
Open AccessImpact of contact rotation on the vacuum arc root movement
This paper aims to investigate the dynamic characteristics of vacuum metal vapor arcs under rotating and traditional direct contact separation modes. Non-symmetrical pure copper electrodes with an anode radius of 7.5 mm and a cathode radius of 22.5 mm are employed in the experiments. The permanent magnet actuator provides an average opening speed of 1.0 m/s for cathode direct separation and 1–3 deg/ms for rotation. Results show that electrode rotation significantly influences the distribution and motion speed of the arc root on the cathode surface.