AAAlicia M. Anderson

Alicia M. Anderson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alicia M. Anderson has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Design and end-to-end validation of a cryogenic far-infrared post-dispersed polarizing Fourier transform spectrometer

    by Matthew A. Buchan, David A. Naylor, Brad G. Gom, Adam J. Christiansen, Alicia M. Anderson, Alain Cournoyer, Éric Carbonneau, Martin Larouche, Hugo A. Bourque, Peter A. R. Ade, et al.

    The PRobe far-Infrared Mission for Astrophysics (PRIMA) will feature a 1.8 m cryogenically cooled telescope that will enable astronomical spectroscopy at both low-resolution and high-resolution over a broad spectral range. In the absence of telescope self-emission and with access to ultra-sensitive detectors, the point source sensitivity of a broad spectral observation is limited by photon noise. The only meaningful way to reduce photon noise is by restricting the instantaneous spectral bandwidth observed by a single detector, typically to a fraction of one percent. In the case of the Far-InfraRed Enhanced Survey Spectrometer (FIRESS) instrument, low-resolution spectroscopy is achieved using several reflection diffraction gratings to restrict the spectral bandwidth. For high-resolution spectroscopy, a Fourier transform spectrometer is placed in front of and in series with the grating spectrometer, which serves as a post-dispersing element to achieve the same goal. The polarization encoding properties of a Martin–Puplett interferometer can exploit the strong polarization dependence of the low-resolution diffraction grating, by ensuring the interferometer output presents the transverse magnetic polarization mode to the grating. We term this hybrid instrument the post-dispersed polarizing Fourier transform spectrometer (PDPFTS). A fully cryogenic far-infrared PDPFTS has been developed in our laboratory to gain a better understanding of the challenges presented by this instrument. The results we present will help to guide the development of FIRESS.


  • Open Access

    Development and validation of a cryogenic far-infrared diffraction grating spectrometer used to post-disperse the output from a Fourier transform spectrometer

    by Alicia M. Anderson, David A. Naylor, Brad G. Gom, Matthew A. Buchan, Adam J. Christiansen, Ian T. Veenendaal

    Recent advances in far-infrared detector technology have led to increases in raw sensitivity of more than an order of magnitude over previous state-of-the-art detectors. With such sensitivity, photon noise becomes the dominant noise component, even when using cryogenically cooled optics, unless a method of restricting the spectral bandpass is employed. The leading instrument concept features reflecting diffraction gratings, which post-disperse the light that has been modulated by a polarizing Fourier transform spectrometer (FTS) onto a detector array, thereby reducing the photon noise on each detector. This paper discusses the development of a cryogenic (4 K) diffraction grating spectrometer that operates over the wavelength range of 285 to 500 μm and was used to post-disperse the output from a room-temperature polarizing FTS. Measurements of the grating spectral response and diffraction efficiency are presented as a function of both wavelength and polarization to characterize the instrumental performance.