Alicia M. Anderson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alicia M. Anderson has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Adam J. Christiansen
Blue Sky Spectroscopy Inc., Suite 9 740 4 Ave S, Lethbridge T1J 0N9, Alberta, Canada
2 shared publications - Matthew A. Buchan
University of Lethbridge, Institute for Space Imaging Science, Department of Physics and Astronomy, Lethbridge, Alberta, Canada
2 shared publications Alain Cournoyer
ABB Inc., Measurements & Analytics Division, Québec, Canada
1 shared publicationBrad G. Gom
University of Lethbridge, Institute for Space Imaging Science, Department of Physics and Astronomy, Lethbridge, Alberta, Canada
1 shared publication- Brad G. Gom
Blue Sky Spectroscopy Inc., Suite 9 740 4 Ave S, Lethbridge T1J 0N9, Alberta, Canada
1 shared publication Carole Tucker
Cardiff University, School of Physics and Astronomy, Cardiff, United Kingdom
1 shared publication
Latest Publications
- 9 June 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 11 (03) , 031640-17
Design and end-to-end validation of a cryogenic far-infrared post-dispersed polarizing Fourier transform spectrometer
The PRobe far-Infrared Mission for Astrophysics (PRIMA) will feature a 1.8 m cryogenically cooled telescope that will enable astronomical spectroscopy at both low-resolution and high-resolution over a broad spectral range. In the absence of telescope self-emission and with access to ultra-sensitive detectors, the point source sensitivity of a broad spectral observation is limited by photon noise. The only meaningful way to reduce photon noise is by restricting the instantaneous spectral bandwidth observed by a single detector, typically to a fraction of one percent. In the case of the Far-InfraRed Enhanced Survey Spectrometer (FIRESS) instrument, low-resolution spectroscopy is achieved using several reflection diffraction gratings to restrict the spectral bandwidth. For high-resolution spectroscopy, a Fourier transform spectrometer is placed in front of and in series with the grating spectrometer, which serves as a post-dispersing element to achieve the same goal. The polarization encoding properties of a Martin–Puplett interferometer can exploit the strong polarization dependence of the low-resolution diffraction grating, by ensuring the interferometer output presents the transverse magnetic polarization mode to the grating. We term this hybrid instrument the post-dispersed polarizing Fourier transform spectrometer (PDPFTS). A fully cryogenic far-infrared PDPFTS has been developed in our laboratory to gain a better understanding of the challenges presented by this instrument. The results we present will help to guide the development of FIRESS.
- 9 June 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 11 (03) , 031640-17
Design and end-to-end validation of a cryogenic far-infrared post-dispersed polarizing Fourier transform spectrometer
The PRobe far-Infrared Mission for Astrophysics (PRIMA) will feature a 1.8 m cryogenically cooled telescope that will enable astronomical spectroscopy at both low-resolution and high-resolution over a broad spectral range. In the absence of telescope self-emission and with access to ultra-sensitive detectors, the point source sensitivity of a broad spectral observation is limited by photon noise. The only meaningful way to reduce photon noise is by restricting the instantaneous spectral bandwidth observed by a single detector, typically to a fraction of one percent. In the case of the Far-InfraRed Enhanced Survey Spectrometer (FIRESS) instrument, low-resolution spectroscopy is achieved using several reflection diffraction gratings to restrict the spectral bandwidth. For high-resolution spectroscopy, a Fourier transform spectrometer is placed in front of and in series with the grating spectrometer, which serves as a post-dispersing element to achieve the same goal. The polarization encoding properties of a Martin–Puplett interferometer can exploit the strong polarization dependence of the low-resolution diffraction grating, by ensuring the interferometer output presents the transverse magnetic polarization mode to the grating. We term this hybrid instrument the post-dispersed polarizing Fourier transform spectrometer (PDPFTS). A fully cryogenic far-infrared PDPFTS has been developed in our laboratory to gain a better understanding of the challenges presented by this instrument. The results we present will help to guide the development of FIRESS.
- Open Access
- 1 January 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (1)
Development and validation of a cryogenic far-infrared diffraction grating spectrometer used to post-disperse the output from a Fourier transform spectrometer
Recent advances in far-infrared detector technology have led to increases in raw sensitivity of more than an order of magnitude over previous state-of-the-art detectors. With such sensitivity, photon noise becomes the dominant noise component, even when using cryogenically cooled optics, unless a method of restricting the spectral bandpass is employed. The leading instrument concept features reflecting diffraction gratings, which post-disperse the light that has been modulated by a polarizing Fourier transform spectrometer (FTS) onto a detector array, thereby reducing the photon noise on each detector. This paper discusses the development of a cryogenic (4 K) diffraction grating spectrometer that operates over the wavelength range of 285 to 500 μm and was used to post-disperse the output from a room-temperature polarizing FTS. Measurements of the grating spectral response and diffraction efficiency are presented as a function of both wavelength and polarization to characterize the instrumental performance.
- 1 January 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (1)
Open AccessDevelopment and validation of a cryogenic far-infrared diffraction grating spectrometer used to post-disperse the output from a Fourier transform spectrometer
Recent advances in far-infrared detector technology have led to increases in raw sensitivity of more than an order of magnitude over previous state-of-the-art detectors. With such sensitivity, photon noise becomes the dominant noise component, even when using cryogenically cooled optics, unless a method of restricting the spectral bandpass is employed. The leading instrument concept features reflecting diffraction gratings, which post-disperse the light that has been modulated by a polarizing Fourier transform spectrometer (FTS) onto a detector array, thereby reducing the photon noise on each detector. This paper discusses the development of a cryogenic (4 K) diffraction grating spectrometer that operates over the wavelength range of 285 to 500 μm and was used to post-disperse the output from a room-temperature polarizing FTS. Measurements of the grating spectral response and diffraction efficiency are presented as a function of both wavelength and polarization to characterize the instrumental performance.