Xiuzhen Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xiuzhen Wang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Chenguang Shen
BSL-3 Laboratory (Guangdong), Guangdong Provincial Key Laboratory of Tropical Disease Research, Ministry of Education Key Laboratory of Infectious Diseases Research in South China, School of Public Health, Southern Medical University, Guangzhou, China
1 shared publication - Huiyang Jie
Department of Detection and Diagnosis Technology Research, Guangzhou National Laboratory, Guangzhou 510000, China
1 shared publication - Qian Liu
Department of Detection and Diagnosis Technology Research Guangzhou National Laboratory Guangzhou Guangdong People's Republic of China
1 shared publication - Sidi Liu
Department of Detection and Diagnosis Technology Research, Guangzhou National Laboratory, Guangzhou 510000, China
1 shared publication - Yu Wang
Department of Detection and Diagnosis Technology Research, Guangzhou National Laboratory, Guangzhou 510000, China
1 shared publication
Latest Publications
- Open Access
- 12 June 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (6) , 305
Enhancing Sensitivity in SARS-CoV-2 Rapid Antigen Testing through Integration of a Water-Soluble Polymer Wall
Lateral flow immunoassays (LFIAs) are recognized for their practicality in homecare and point-of-care testing, owing to their simplicity, cost-efficiency, and rapid visual readouts. Despite these advantages, LFIAs typically fall short in sensitivity, particularly in detecting viruses such as SARS-CoV-2, thus limiting their broader application. In response to this challenge, we have innovated an approach to substantially enhance LFIA sensitivity. This involves the integration of a water-soluble dextran–methacrylate polymer wall with a 15% grafting degree positioned between the test and control lines on the LFIA strip. This novel modification significantly improved the sensitivity of the assay, achieving detection limits as low as 50 pg mL−1 and enhancing the sensitivity by 5–20-fold relative to existing LFIA kits available on the market. Furthermore, our developed LFIA kit (WSPW-LFIA) demonstrated exceptional specificity for SARS-CoV-2. Coupled with a straightforward fabrication process and robust stability, the WSPW-LFIA represents a promising advancement for real-time in vitro diagnosis across a spectrum of diseases.
- 12 June 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (6) , 305
Open AccessEnhancing Sensitivity in SARS-CoV-2 Rapid Antigen Testing through Integration of a Water-Soluble Polymer Wall
Lateral flow immunoassays (LFIAs) are recognized for their practicality in homecare and point-of-care testing, owing to their simplicity, cost-efficiency, and rapid visual readouts. Despite these advantages, LFIAs typically fall short in sensitivity, particularly in detecting viruses such as SARS-CoV-2, thus limiting their broader application. In response to this challenge, we have innovated an approach to substantially enhance LFIA sensitivity. This involves the integration of a water-soluble dextran–methacrylate polymer wall with a 15% grafting degree positioned between the test and control lines on the LFIA strip. This novel modification significantly improved the sensitivity of the assay, achieving detection limits as low as 50 pg mL−1 and enhancing the sensitivity by 5–20-fold relative to existing LFIA kits available on the market. Furthermore, our developed LFIA kit (WSPW-LFIA) demonstrated exceptional specificity for SARS-CoV-2. Coupled with a straightforward fabrication process and robust stability, the WSPW-LFIA represents a promising advancement for real-time in vitro diagnosis across a spectrum of diseases.