Mauro Lúcio Gonçalves de Oliveira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mauro Lúcio Gonçalves de Oliveira has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Ana Paula Pontelo
Laboratório Nacional Agropecuário – LANAGRO/MG, Ministry of Agriculture, Livestock and Food Supply of Brazil , Pesticides Laboratory, Av. Rômulo Joviano s/n – Fazenda Modelo, Postal Code: 33.600-000, Pedro Leopoldo-MG/Brazil
1 shared publicationCláudia Paes
Laboratório Nacional Agropecuário – LANAGRO/MG, Ministry of Agriculture, Livestock and Food Supply of Brazil , Pesticides Laboratory, Av. Rômulo Joviano s/n – Fazenda Modelo, Postal Code: 33.600-000, Pedro Leopoldo-MG/Brazil
1 shared publicationFabiano Aurélio
Laboratório Nacional Agropecuário – LANAGRO/MG, Ministry of Agriculture, Livestock and Food Supply of Brazil , Pesticides Laboratory, Av. Rômulo Joviano s/n – Fazenda Modelo, Postal Code: 33.600-000, Pedro Leopoldo-MG/Brazil
1 shared publicationFernando Diniz Madureira
Laboratório Nacional Agropecuário – LANAGRO/MG, Ministry of Agriculture, Livestock and Food Supply of Brazil , Pesticides Laboratory, Av. Rômulo Joviano s/n – Fazenda Modelo, Postal Code: 33.600-000, Pedro Leopoldo-MG/Brazil
1 shared publicationGilsara Silva
Laboratório Nacional Agropecuário – LANAGRO/MG, Ministry of Agriculture, Livestock and Food Supply of Brazil , Pesticides Laboratory, Av. Rômulo Joviano s/n – Fazenda Modelo, Postal Code: 33.600-000, Pedro Leopoldo-MG/Brazil
1 shared publicationReginaldo Oliveira
Laboratório Nacional Agropecuário – LANAGRO/MG, Ministry of Agriculture, Livestock and Food Supply of Brazil , Pesticides Laboratory, Av. Rômulo Joviano s/n – Fazenda Modelo, Postal Code: 33.600-000, Pedro Leopoldo-MG/Brazil
1 shared publication
Latest Publications
- 1 February 2012
- Published by Taylor & Francis in Food Additives & Contaminants: Part A
- Vol. 29 (4) , 657-664
A multi-residue method for the determination of pesticides in high water content matrices by gas chromatography–single quadrupole mass spectrometry with electron ionisation (EI-GC/MS)
An EI-GC/MS method for the determination of pesticide residues in vegetable matrices with high water content was validated using papaya samples. The validation of a multi-residue pesticide method was in agreement with national and international regulations enabling the Ministry of the Agriculture, Livestock and Food Supply of Brazil to cover a large number of matrices and pesticide residues in its monitoring and control programmes. The extraction used 60 mL of ethyl acetate and 30 g of sample previously processed. After extraction, clean-up of all the extracts was carried out by percolation through GBC cartridges. The samples were then injected in an EI-GC/MS system. Calibration curves were prepared in quadruplet by fortifying blank extracts with a standard solution containing all the pesticides studied at 0.000, 0.005, 0.010, 0.020, 0.030, 0.050, 0.080 and 0.100 mg kg−1. For the recovery study, blank samples were fortified at 0.010, 0.020, 0.030, 0.050 and 0.080 mg kg−1 and then submitted to the extraction procedure. The complete procedure was repeated over four different days by two analysts. The regression parameters of calibration curves were calculated for each validation day. Linearity, selectivity, specificity, robustness, limits of detection and quantification were also assessed. The uncertainty was estimated for each analyte at each spike level studied. The method had recoveries between 91% and 105% and precision results ≤20%. Limits of quantification were below or equal to the maximum residue limits (MRLs) regulated by Brazilian legislation. The MRLs of the selected pesticides are not regulated by CODEX Alimentarius. The results are also in agreement with SANCO/10684/2009.
- 1 February 2012
- Published by Taylor & Francis in Food Additives & Contaminants: Part A
- Vol. 29 (4) , 657-664
A multi-residue method for the determination of pesticides in high water content matrices by gas chromatography–single quadrupole mass spectrometry with electron ionisation (EI-GC/MS)
An EI-GC/MS method for the determination of pesticide residues in vegetable matrices with high water content was validated using papaya samples. The validation of a multi-residue pesticide method was in agreement with national and international regulations enabling the Ministry of the Agriculture, Livestock and Food Supply of Brazil to cover a large number of matrices and pesticide residues in its monitoring and control programmes. The extraction used 60 mL of ethyl acetate and 30 g of sample previously processed. After extraction, clean-up of all the extracts was carried out by percolation through GBC cartridges. The samples were then injected in an EI-GC/MS system. Calibration curves were prepared in quadruplet by fortifying blank extracts with a standard solution containing all the pesticides studied at 0.000, 0.005, 0.010, 0.020, 0.030, 0.050, 0.080 and 0.100 mg kg−1. For the recovery study, blank samples were fortified at 0.010, 0.020, 0.030, 0.050 and 0.080 mg kg−1 and then submitted to the extraction procedure. The complete procedure was repeated over four different days by two analysts. The regression parameters of calibration curves were calculated for each validation day. Linearity, selectivity, specificity, robustness, limits of detection and quantification were also assessed. The uncertainty was estimated for each analyte at each spike level studied. The method had recoveries between 91% and 105% and precision results ≤20%. Limits of quantification were below or equal to the maximum residue limits (MRLs) regulated by Brazilian legislation. The MRLs of the selected pesticides are not regulated by CODEX Alimentarius. The results are also in agreement with SANCO/10684/2009.