Shekher Kummari
Shekher Kummari has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Drew A. Hall
University of California, San Diego
2 shared publications Alexander Latham
Allegro MicroSystems
1 shared publicationFlorencia Ferrer
Allegro MicroSystems
1 shared publication- Guillermo Airaldi
Allegro MicroSystems
1 shared publication - Joel Bisarra
Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA, USA
1 shared publication - Kauveri Vengatajalabathy Gobi
National Institute of Technology Warangal
1 shared publication
Latest Publications
Development of 1D‐Metalloid‐Induced Highly Porous Carbon Nanofiber Conjugated with PEDOT Polymer Through Concurrent Selenization of ZIF‐67 for Energy Storage and Green H 2 Production
Manufacturing high‐performance and cost‐affordable non‐metallic, electroactive 1D carbon material for energy storage and hydrogen evolution reaction (HER) is of foremost importance to respond positively to the impending energy crisis. Porous N‐doped carbon nanofiber (PNCNF) is successfully synthesized by electrospinning, using selenium nanoparticles as a sacrificial template (where Se is reutilized for ZIF‐67 selenization as a bi‐process, and the surface of PNCNF is modified with poly(3,4‐ethylenedioxythiophene) (PNCNT/PEDOT) by electropolymerization. The prepared materials are found ideal for energy storage (supercapacitor) and electrocatalysis (HER). The bi‐functional material has shown excellent energy storage capability with the specific capacitance (C S ) of 230 F g −1 (PNCNF) and 395 F g −1 (PNCNF/PEDOT), and the symmetric supercapacitor device, PNCNF/PEDOT//PEDOT/PNCNF, exhibits 32.4 Wh kg −1 energy density at 14400 W kg −1 power density with 96.6% Coulombic efficiency and 106% C S at the end of 5000 charge–discharge cycles. The rate capability of the symmetric supercapacitor cell of PNCNF/PEDOT is 51% for the current density increase from 1 to 8 A g −1 , while that of PNCNF is a meager 29% only. Electrocatalytic HER at the PNCNF electrode is achieved with an overpotential of 281 mV@10 mA cm −2 relative to the Pt/C electrode and a low Tafel slop value of 96 mV dec −1 .
Development of 1D‐Metalloid‐Induced Highly Porous Carbon Nanofiber Conjugated with PEDOT Polymer Through Concurrent Selenization of ZIF‐67 for Energy Storage and Green H 2 Production
Manufacturing high‐performance and cost‐affordable non‐metallic, electroactive 1D carbon material for energy storage and hydrogen evolution reaction (HER) is of foremost importance to respond positively to the impending energy crisis. Porous N‐doped carbon nanofiber (PNCNF) is successfully synthesized by electrospinning, using selenium nanoparticles as a sacrificial template (where Se is reutilized for ZIF‐67 selenization as a bi‐process, and the surface of PNCNF is modified with poly(3,4‐ethylenedioxythiophene) (PNCNT/PEDOT) by electropolymerization. The prepared materials are found ideal for energy storage (supercapacitor) and electrocatalysis (HER). The bi‐functional material has shown excellent energy storage capability with the specific capacitance (C S ) of 230 F g −1 (PNCNF) and 395 F g −1 (PNCNF/PEDOT), and the symmetric supercapacitor device, PNCNF/PEDOT//PEDOT/PNCNF, exhibits 32.4 Wh kg −1 energy density at 14400 W kg −1 power density with 96.6% Coulombic efficiency and 106% C S at the end of 5000 charge–discharge cycles. The rate capability of the symmetric supercapacitor cell of PNCNF/PEDOT is 51% for the current density increase from 1 to 8 A g −1 , while that of PNCNF is a meager 29% only. Electrocatalytic HER at the PNCNF electrode is achieved with an overpotential of 281 mV@10 mA cm −2 relative to the Pt/C electrode and a low Tafel slop value of 96 mV dec −1 .
- 30 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (4) , 756-770
Mitigating Medication Tampering and Diversion via Real-Time Intravenous Opioid Quantification
Opioid tampering and diversion pose a serious problem for hospital patients with potentially life-threatening consequences. The ongoing opioid crisis has resulted in medications used for pain management and anesthesia, such as fentanyl and morphine, being stolen, substituted with a different substance, and abused. This work aims to mitigate tampering and diversion through analytical verification of the administered drug before it enters the patient. We present an electrochemical-based sensor and miniaturized wireless potentiostat that enable real-time intravenous (IV) monitoring of opioids, specifically fentanyl and morphine. The proposed system is connected to an IV drip system during surgery or post-operation recovery. Measurement results of two opioids are presented, including calibration curves and data on the sensor performance concerning pH, temperature, interference, reproducibility, and long-term stability. Finally, we demonstrate real-time fluidic measurements connected to a flow cell to simulate IV administration and a blind study classified using a machine-learning algorithm. The system achieves limits of detection (LODs) of 1.26 μg/mL and 2.75 μg/mL for fentanyl and morphine, respectively, while operating with >1-month battery lifetime due to an optimized ultra-low power 36 μA sleep mode.
- 30 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (4) , 756-770
Mitigating Medication Tampering and Diversion via Real-Time Intravenous Opioid Quantification
Opioid tampering and diversion pose a serious problem for hospital patients with potentially life-threatening consequences. The ongoing opioid crisis has resulted in medications used for pain management and anesthesia, such as fentanyl and morphine, being stolen, substituted with a different substance, and abused. This work aims to mitigate tampering and diversion through analytical verification of the administered drug before it enters the patient. We present an electrochemical-based sensor and miniaturized wireless potentiostat that enable real-time intravenous (IV) monitoring of opioids, specifically fentanyl and morphine. The proposed system is connected to an IV drip system during surgery or post-operation recovery. Measurement results of two opioids are presented, including calibration curves and data on the sensor performance concerning pH, temperature, interference, reproducibility, and long-term stability. Finally, we demonstrate real-time fluidic measurements connected to a flow cell to simulate IV administration and a blind study classified using a machine-learning algorithm. The system achieves limits of detection (LODs) of 1.26 μg/mL and 2.75 μg/mL for fentanyl and morphine, respectively, while operating with >1-month battery lifetime due to an optimized ultra-low power 36 μA sleep mode.