Oksana Kalinkevich
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Oksana Kalinkevich has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Aleksei N. Kalinkevich
Institute of Applied Physics NASU, 40000 Sumy, Ukraine
2 shared publications - Maksym Pogorielov
Sumy State University
2 shared publications - Agata Jakóbik-Kolon
Department of Inorganic, Analytical Chemistry and Electrochemistry, Faculty of Chemistry, Silesian University of Technology, Krzywoustego 6, 44-100 Gliwice, Poland
1 shared publication - Aleksandr Kulik
Institute of Applied Physics, National Academy of Sciences of Ukraine, Sumy, Ukraine
1 shared publication Alena Zlatska
Biotechnology Laboratory Ilaya Regeneration, Medical Company Ilaya, 03115 Kyiv, Ukraine
1 shared publication- Alicja Kazek-Kęsik
Department of Inorganic Chemistry, Analytical Chemistry and Electrochemistry, Faculty of Chemistry, Silesian University of Technology, Krzywoustego 6 Str., 44-100 Gliwice, Poland
1 shared publication
Latest Publications
- Open Access
- 21 May 2021
- Published by MDPI AG in Biomedicines
- Vol. 9 (6) , 588
Hemostatic and Tissue Regeneration Performance of Novel Electrospun Chitosan-Based Materials
The application of chitosan (Ch) as a promising biopolymer with hemostatic properties and high biocompatibility is limited due to its prolonged degradation time, which, in turn, slows the repair process. In the present research, we aimed to develop new technologies to reduce the biodegradation time of Ch-based materials for hemostatic application. This study was undertaken to assess the biocompatibility and hemostatic and tissue-regeneration performance of Ch-PEO-copolymer prepared by electrospinning technique. Chitosan electrospinning membranes (ChEsM) were made from Ch and polyethylene oxide (PEO) powders for rich high-porous material with sufficient hemostatic parameters. The structure, porosity, density, antibacterial properties, in vitro degradation and biocompatibility of ChEsM were evaluated and compared to the conventional Ch sponge (ChSp). In addition, the hemostatic and bioactive performance of both materials were examined in vivo, using the liver-bleeding model in rats. A penetrating punch biopsy of the left liver lobe was performed to simulate bleeding from a non-compressible irregular wound. Appropriately shaped ChSp or ChEsM were applied to tissue lesions. Electrospinning allows us to produce high-porous membranes with relevant ChSp degradation and swelling properties. Both materials demonstrated high biocompatibility and hemostatic effectiveness in vitro. However, the antibacterial properties of ChEsM were not as good when compared to the ChSp. In vivo studies confirmed superior ChEsM biocompatibility and sufficient hemostatic performance, with tight interplay with host cells and tissues. The in vivo model showed a higher biodegradation rate of ChEsM and advanced liver repair.
- 21 May 2021
- Published by MDPI AG in Biomedicines
- Vol. 9 (6) , 588
Open AccessHemostatic and Tissue Regeneration Performance of Novel Electrospun Chitosan-Based Materials
The application of chitosan (Ch) as a promising biopolymer with hemostatic properties and high biocompatibility is limited due to its prolonged degradation time, which, in turn, slows the repair process. In the present research, we aimed to develop new technologies to reduce the biodegradation time of Ch-based materials for hemostatic application. This study was undertaken to assess the biocompatibility and hemostatic and tissue-regeneration performance of Ch-PEO-copolymer prepared by electrospinning technique. Chitosan electrospinning membranes (ChEsM) were made from Ch and polyethylene oxide (PEO) powders for rich high-porous material with sufficient hemostatic parameters. The structure, porosity, density, antibacterial properties, in vitro degradation and biocompatibility of ChEsM were evaluated and compared to the conventional Ch sponge (ChSp). In addition, the hemostatic and bioactive performance of both materials were examined in vivo, using the liver-bleeding model in rats. A penetrating punch biopsy of the left liver lobe was performed to simulate bleeding from a non-compressible irregular wound. Appropriately shaped ChSp or ChEsM were applied to tissue lesions. Electrospinning allows us to produce high-porous membranes with relevant ChSp degradation and swelling properties. Both materials demonstrated high biocompatibility and hemostatic effectiveness in vitro. However, the antibacterial properties of ChEsM were not as good when compared to the ChSp. In vivo studies confirmed superior ChEsM biocompatibility and sufficient hemostatic performance, with tight interplay with host cells and tissues. The in vivo model showed a higher biodegradation rate of ChEsM and advanced liver repair.
- Open Access
Formation of a Bacteriostatic Surface on ZrNb Alloy via Anodization in a Solution Containing Cu Nanoparticles
High strength, excellent corrosion resistance, high biocompatibility, osseointegration ability, and low bacteria adhesion are critical properties of metal implants. Additionally, the implant surface plays a critical role as the cell and bacteria host, and the development of a simultaneously antibacterial and biocompatible implant is still a crucial challenge. Copper nanoparticles (CuNPs) could be a promising alternative to silver in antibacterial surface engineering due to low cell toxicity. In our study, we assessed the biocompatibility and antibacterial properties of a PEO (plasma electrolytic oxidation) coating incorporated with CuNPs (Cu nanoparticles). The structural and chemical parameters of the CuNP and PEO coating were studied with TEM/SEM (Transmission Electron Microscopy/Scanning Electron Microscopy), EDX (Energy-Dispersive X-ray Dpectroscopy), and XRD (X-ray Diffraction) methods. Cell toxicity and bacteria adhesion tests were used to prove the surface safety and antibacterial properties. We can conclude that PEO on a ZrNb alloy in Ca–P solution with CuNPs formed a stable ceramic layer incorporated with Cu nanoparticles. The new surface provided better osteoblast adhesion in all time-points compared with the nontreated metal and showed medium grade antibacterial activities. PEO at 450 V provided better antibacterial properties that are recommended for further investigation.
Open AccessFormation of a Bacteriostatic Surface on ZrNb Alloy via Anodization in a Solution Containing Cu Nanoparticles
High strength, excellent corrosion resistance, high biocompatibility, osseointegration ability, and low bacteria adhesion are critical properties of metal implants. Additionally, the implant surface plays a critical role as the cell and bacteria host, and the development of a simultaneously antibacterial and biocompatible implant is still a crucial challenge. Copper nanoparticles (CuNPs) could be a promising alternative to silver in antibacterial surface engineering due to low cell toxicity. In our study, we assessed the biocompatibility and antibacterial properties of a PEO (plasma electrolytic oxidation) coating incorporated with CuNPs (Cu nanoparticles). The structural and chemical parameters of the CuNP and PEO coating were studied with TEM/SEM (Transmission Electron Microscopy/Scanning Electron Microscopy), EDX (Energy-Dispersive X-ray Dpectroscopy), and XRD (X-ray Diffraction) methods. Cell toxicity and bacteria adhesion tests were used to prove the surface safety and antibacterial properties. We can conclude that PEO on a ZrNb alloy in Ca–P solution with CuNPs formed a stable ceramic layer incorporated with Cu nanoparticles. The new surface provided better osteoblast adhesion in all time-points compared with the nontreated metal and showed medium grade antibacterial activities. PEO at 450 V provided better antibacterial properties that are recommended for further investigation.
- 13 June 2020
- Published by Springer Nature in Biological Trace Element Research
- Vol. 199 (3) , 935-943
A Simple Method to Determine the Fractions of Labile and Mineral-Bound Microelements in Bone Tissue by Atomic Absorption Spectrometry
In this work a simple and inexpensive method to assess the concentration ratio of the labile and mineral-bound microelements of the bone tissue was developed. The approach is based on the separation of the components of bone tissue by their selective solubility with the subsequent determination of microelements with atomic absorption spectrometry. The total concentrations of Mg, Zn, Fe, Sr, Al, Cu, and Mn and the concentrations of these elements in aqueous solutions with pH 6.5, 10, and 12 after their ultrasonically activated interaction with the powder of dried bone were determined. Two quite different bone samples were analyzed: a cortical fragment of the femur of a mature healthy cow and the spongy part of a human femoral head affected by osteoporosis. Some common and individual features of the both type of bones in regard to the total concentrations and fractional distribution of microelements are discussed. The obtained concentrations of the “soluble” fractions of microelements were critically analyzed taking into account the possible reactions leading to new insoluble phases’ formation in alkaline solutions. Based on the data obtained, the ability of elements to form labile fractions in the bone tissue could be arranged in the following descending series: Mg ≥ Zn > Al > Fe > Mn > Cu > Sr.
- 13 June 2020
- Published by Springer Nature in Biological Trace Element Research
- Vol. 199 (3) , 935-943
A Simple Method to Determine the Fractions of Labile and Mineral-Bound Microelements in Bone Tissue by Atomic Absorption Spectrometry
In this work a simple and inexpensive method to assess the concentration ratio of the labile and mineral-bound microelements of the bone tissue was developed. The approach is based on the separation of the components of bone tissue by their selective solubility with the subsequent determination of microelements with atomic absorption spectrometry. The total concentrations of Mg, Zn, Fe, Sr, Al, Cu, and Mn and the concentrations of these elements in aqueous solutions with pH 6.5, 10, and 12 after their ultrasonically activated interaction with the powder of dried bone were determined. Two quite different bone samples were analyzed: a cortical fragment of the femur of a mature healthy cow and the spongy part of a human femoral head affected by osteoporosis. Some common and individual features of the both type of bones in regard to the total concentrations and fractional distribution of microelements are discussed. The obtained concentrations of the “soluble” fractions of microelements were critically analyzed taking into account the possible reactions leading to new insoluble phases’ formation in alkaline solutions. Based on the data obtained, the ability of elements to form labile fractions in the bone tissue could be arranged in the following descending series: Mg ≥ Zn > Al > Fe > Mn > Cu > Sr.