LCLiming Chen

Liming Chen

*This is an algorithmically generated author record based on publicly available information.

Liming Chen has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    CFG-Net: A Coarse-to-Fine Grouping Network for Surface Defect Rating

    by Kai Tian, Dehao Meng, Kai Wang, Yongzhen Ke, Shuai Yang, Liming Chen, Jianghong Hu, Changku Sun, Xiaodong Zhang

    Automatic surface defect rating is vital for industrial quality control but faces challenges in handling diverse defect scales and learning ordinal relationships with ambiguous boundaries. To address the inherent contradiction between scale and ordinality processing, we propose CFG-Net (Coarse-to-Fine Grouping Network), which adopts a "divide-and-conquer" strategy to decouple multi-scale rating tasks. CFG-Net uses a dual-stream grouping-gating module with lossless pixel unshuffle for initial-scale grouping and localization. Defects are dynamically dispatched to specialized branches: a low-level branch using anchor difference to amplify weak anomaly signals, and a high-level branch using deformable convolutions to fit irregular contours. Features are integrated via an adaptive ordinal fusion module guided by gating probabilities. Furthermore, we introduce a Multi-Margin N-Pair (MMNP) contrastive loss to construct an ordinal manifold space that strictly aligns with defect severity levels. Experimental results on real-world industrial datasets show that CFG-Net effectively resolves mixed-scale conflicts, achieving 97.2% group classification accuracy and 65.7% fine-grained rating accuracy. With a Mean Absolute Error (MAE) of 0.45 and Mean Squared Error (MSE) of 0.58, the proposed architecture demonstrates high precision and engineering robustness for complex, multi-scale defect rating tasks.

  • Group-Driven Causal Modeling and Root Cause Analysis for High-Dimensional Time Series

    by Yongkun Han, Kai Wang, Liming Chen, Yongzhen Ke, Shuai Yang, Kai Tian

    Root Cause Analysis (RCA) is vital for industrial monitoring and network diagnosis. In high-dimensional scenarios, traditional causal modeling is susceptible to noise and redundant dependencies, leading to unstable causal structures and poor interpretability. This paper proposes a novel method, GCRA (Group-Driven Causal Modeling and Root Cause Analysis), to address these challenges. First, the method utilizes cross-correlation to construct variable groups, establishing a group-level causal graph to effectively manage complex dependencies. Second, a mapping mechanism gradually refines this group-level graph into a variable-level structure. This structure guides the reconstruction of time-series observations, while structure-guided predictors are designed to model exogenous interventions representing unpredictable external disturbances. Finally, fine-grained RCA is achieved by calculating attribution scores based on these exogenous interventions. Experimental results across three synthetic and one real-world dataset demonstrate that GCRA accurately captures causal relationships and identifies root causes. The findings validate that group-level construction and structure-guided modeling significantly stabilize causal structures and enhance localization accuracy in high-dimensional data.

  • Motion-vector calibration for industrial translational laser profilometers under arbitrary mounting orientations

    by Minxue Wang, Menghang Chen, Liming Chen, Ang Zhang, Xu Li, Zezhen Zhang, Yanyu Ding, Jianquan Yao, Xiaodong Zhang

    Industrial laser profile sensor requires linear motion module to acquire three-dimensional data. Accurate calibration of their relative pose is crucial for applications such as 3D contour scanning of mechanical parts, point cloud registration, defect detection, and precision measurement. This paper presents a novel motion vector calibration method that is applicable to arbitrary mounting orientations for an industrial translational laser profile sensor system, offering high accuracy and efficiency. An innovative calibration device, featuring multiple planar surfaces at distinct poses, was designed and manufactured. The relative pose between the laser profile sensor and the calibration device was calibrated from a single measurement using a proposed four-feature-point algorithm without any secondary camera. Subsequently, with the linear motion module moving to capture a sequence of profiles, a hybrid global–local nonlinear optimization method was employed to calibrate the motion vector between the sensor and the module. Experimental validation demonstrated that this method achieves an overall measurement accuracy of less than 0.030 mm and a repeatability within 0.005 mm over a 100 mm travel range, confirming its feasibility and stability for high-precision industrial applications.