Chie Kamada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chie Kamada has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Ayumu Yamaoka
Department of Neurosurgery, Sapporo Medical University, Sapporo, Hokkaido, Japan
2 shared publications Nobuhiro Mikuni
Department of Neurosurgery, Sapporo Medical University, Sapporo, Hokkaido, Japan
2 shared publicationsSangnyon Kim
Department of Neurosurgery, Sapporo Medical University, Sapporo, Hokkaido, Japan
2 shared publicationsAya Kanno
Sapporo Med Univ, Dept Neurosurg, Sapporo, Japan
1 shared publicationEmiru Tsunoo
1 shared publicationHiroki Ota
Department of Neurosurgery, Sapporo Medical University, Sapporo, Hokkaido, Japan
1 shared publication
Latest Publications
- Open Access
- 25 May 2026
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Case Lessons
- Vol. 11 (21)
Stent-assisted coil embolization for a graft-related aneurysm following high-flow bypass: illustrative case
BACKGROUND: High-flow bypass (HFB) combined with parent artery occlusion is an established treatment for complex cerebral aneurysms. Graft-related aneurysm (GA) at the anastomotic site is a rare late complication of HFB, and its optimal management remains poorly defined. The authors report a case of an unruptured GA that enlarged more than 10 years after HFB and was treated with stent-assisted coil embolization (SACE). OBSERVATIONS: A 50-year-old woman had undergone HFB using a radial artery (RA) graft for a cavernous segment aneurysm of the internal carotid artery 10 years earlier. A small aneurysmal dilation at the anastomosis was detected 2 years postoperatively, but long-term follow-up was interrupted. Ten years after the initial surgery, imaging revealed enlargement of a saccular GA with a bleb at the anastomotic site. SACE was performed through the tortuous RA graft using a distal access catheter for stable support, with deployment of an intracranial stent across the anastomosis to secure coil stability. Complete aneurysm occlusion was achieved without procedural complications. Follow-up cerebral angiography confirmed durable occlusion with preserved bypass patency. LESSONS: GA can occur as a late complication after HFB, underscoring the importance of long-term follow-up and medical management. Endovascular treatment may represent a less invasive treatment option in selected cases. https://thejns.org/doi/10.3171/CASE26249
- 25 May 2026
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Case Lessons
- Vol. 11 (21)
Open AccessStent-assisted coil embolization for a graft-related aneurysm following high-flow bypass: illustrative case
BACKGROUND: High-flow bypass (HFB) combined with parent artery occlusion is an established treatment for complex cerebral aneurysms. Graft-related aneurysm (GA) at the anastomotic site is a rare late complication of HFB, and its optimal management remains poorly defined. The authors report a case of an unruptured GA that enlarged more than 10 years after HFB and was treated with stent-assisted coil embolization (SACE). OBSERVATIONS: A 50-year-old woman had undergone HFB using a radial artery (RA) graft for a cavernous segment aneurysm of the internal carotid artery 10 years earlier. A small aneurysmal dilation at the anastomosis was detected 2 years postoperatively, but long-term follow-up was interrupted. Ten years after the initial surgery, imaging revealed enlargement of a saccular GA with a bleb at the anastomotic site. SACE was performed through the tortuous RA graft using a distal access catheter for stable support, with deployment of an intracranial stent across the anastomosis to secure coil stability. Complete aneurysm occlusion was achieved without procedural complications. Follow-up cerebral angiography confirmed durable occlusion with preserved bypass patency. LESSONS: GA can occur as a late complication after HFB, underscoring the importance of long-term follow-up and medical management. Endovascular treatment may represent a less invasive treatment option in selected cases. https://thejns.org/doi/10.3171/CASE26249
- Open Access
- 1 January 2026
- Published by The Japanese Society for Neuroendovascular Therapy in Journal of Neuroendovascular Therapy
- Vol. 20 (1)
Angiographically Occult Perforator Ischemia Detected by Motor-Evoked Potential Monitoring during Woven EndoBridge Deployment: A Case Report
Objective: To demonstrate that intraoperative motor-evoked potential (MEP) monitoring can detect angiographically occult perforator ischemia caused by intermediate catheter–induced luminal occupation and flow restriction during Woven EndoBridge (WEB; Terumo Neuro, Aliso Viejo, CA, USA) deployment, which would otherwise remain unrecognized.Case Presentation: A woman in her 60s underwent WEB deployment for an unruptured left middle cerebral artery aneurysm under general anesthesia with intraoperative MEP monitoring using an optimized transcranial electrical stimulation protocol. Immediately prior to device deployment, MEP amplitudes abruptly disappeared in the right extremities. DSA showed preserved lenticulostriate artery opacification; however, the M1 segment was nearly completely occupied by the intermediate catheter. Catheter-induced perforator ischemia was suspected, and the catheter was promptly withdrawn to the cavernous internal carotid artery. MEP signals fully recovered within approximately 4 minutes, and WEB deployment was completed without further incident. Postoperative MRI revealed a small lacunar infarction in the lenticulostriate territory, but the patient was discharged without neurological deficits.Conclusion: Intermediate catheter–induced luminal occupation of the parent artery can cause angiographically occult perforator ischemia detectable only by functional monitoring. MEP monitoring may serve as a critical safeguard during WEB deployment and other neuroendovascular procedures involving large-bore intermediate catheters in perforator-rich arterial segments.
- 1 January 2026
- Published by The Japanese Society for Neuroendovascular Therapy in Journal of Neuroendovascular Therapy
- Vol. 20 (1)
Open AccessAngiographically Occult Perforator Ischemia Detected by Motor-Evoked Potential Monitoring during Woven EndoBridge Deployment: A Case Report
Objective: To demonstrate that intraoperative motor-evoked potential (MEP) monitoring can detect angiographically occult perforator ischemia caused by intermediate catheter–induced luminal occupation and flow restriction during Woven EndoBridge (WEB; Terumo Neuro, Aliso Viejo, CA, USA) deployment, which would otherwise remain unrecognized.Case Presentation: A woman in her 60s underwent WEB deployment for an unruptured left middle cerebral artery aneurysm under general anesthesia with intraoperative MEP monitoring using an optimized transcranial electrical stimulation protocol. Immediately prior to device deployment, MEP amplitudes abruptly disappeared in the right extremities. DSA showed preserved lenticulostriate artery opacification; however, the M1 segment was nearly completely occupied by the intermediate catheter. Catheter-induced perforator ischemia was suspected, and the catheter was promptly withdrawn to the cavernous internal carotid artery. MEP signals fully recovered within approximately 4 minutes, and WEB deployment was completed without further incident. Postoperative MRI revealed a small lacunar infarction in the lenticulostriate territory, but the patient was discharged without neurological deficits.Conclusion: Intermediate catheter–induced luminal occupation of the parent artery can cause angiographically occult perforator ischemia detectable only by functional monitoring. MEP monitoring may serve as a critical safeguard during WEB deployment and other neuroendovascular procedures involving large-bore intermediate catheters in perforator-rich arterial segments.
- 23 May 2024
- Published by Elsevier in World Neurosurgery
- Vol. 188, e288-e296
Functional Brain Mapping Using Depth Electrodes
- 23 May 2024
- Published by Elsevier in World Neurosurgery
- Vol. 188, e288-e296
Functional Brain Mapping Using Depth Electrodes
- Open Access
Polyphone disambiguation and accent prediction using pre-trained language models in Japanese TTS front-end
Although end-to-end text-to-speech (TTS) models can generate natural speech, challenges still remain when it comes to estimating sentence-level phonetic and prosodic information from raw text in Japanese TTS systems. In this paper, we propose a method for polyphone disambiguation (PD) and accent prediction (AP). The proposed method incorporates explicit features extracted from morphological analysis and implicit features extracted from pre-trained language models (PLMs). We use BERT and Flair embeddings as implicit features and examine how to combine them with explicit features. Our objective evaluation results showed that the proposed method improved the accuracy by 5.7 points in PD and 6.0 points in AP. Moreover, the perceptual listening test results confirmed that a TTS system employing our proposed model as a front-end achieved a mean opinion score close to that of synthesized speech with ground-truth pronunciation and accent in terms of naturalness.
Open AccessPolyphone disambiguation and accent prediction using pre-trained language models in Japanese TTS front-end
Although end-to-end text-to-speech (TTS) models can generate natural speech, challenges still remain when it comes to estimating sentence-level phonetic and prosodic information from raw text in Japanese TTS systems. In this paper, we propose a method for polyphone disambiguation (PD) and accent prediction (AP). The proposed method incorporates explicit features extracted from morphological analysis and implicit features extracted from pre-trained language models (PLMs). We use BERT and Flair embeddings as implicit features and examine how to combine them with explicit features. Our objective evaluation results showed that the proposed method improved the accuracy by 5.7 points in PD and 6.0 points in AP. Moreover, the perceptual listening test results confirmed that a TTS system employing our proposed model as a front-end achieved a mean opinion score close to that of synthesized speech with ground-truth pronunciation and accent in terms of naturalness.