JLJiabao Liu

Jiabao Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jiabao Liu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Response and Flow Characteristics of an Angular Momentum Flowmeter

    by Hao Zan, Qiusheng Jia, Chengli Liu, Jiabao Liu, Fuji Huang, Shenmei Zhou

    The angular momentum flowmeter addresses critical challenges in aviation fuel flow measurement during commercial flight operations. This study designed a visualization platform to observe the dynamic responses of internal components under varying flow conditions. By employing the sliding mesh method coupled with an angular momentum algorithm, it enabled the dynamic rotation simulation of the upstream straight-bladed rotor and provided calculation of the deflection angle in the downstream straight-bladed rotor of an angular momentum flowmeter. Experimental results categorize the flow process into three distinct regimes based on flat and spiral spring response states: pre-spring, single-spring, and dual-spring regimes. Under a flow condition of 0.091 kg/s, the upstream straight-bladed rotor maintained stable rotation at a speed of 1.1 rad/s. At a flow rate of 0.20 kg/s, the flat spring initiated outward expansion, and with further increase in flow rate, the rotational speed of the upstream straight-bladed rotor remained within the range of 25.34–26.21 rad/s. Mathematical analysis demonstrates that the flat spring configuration extends the lower measurement limit and promotes dissipation of the secondary vortex through dominant kinetic energy of the primary vortex during dual-spring operation, thereby improving high-pressure zone stability. This work elucidates the operational mechanism of angular momentum flowmeters and provides a theoretical basis for structural optimization.

  • Open Access

    Effect of Axial Clearance Variation on Dual-Rotor Flowmeter Performance

    by Fuji Huang, Liang Yan, Chabi Christian Monsia, Yuxiang Han, Jiabao Liu, Hao Zan

    This study examines the impact of axial clearance variations on the performance characteristics of a dual-rotor flowmeter (DRT-FM) through numerical simulations, with the validity of the numerical results verified by calibration experiments. The results indicate that within the range of 200 L/h to 1600 L/h, the K factors of different groups increase as clearance increases. The K factor of the 0.80 mm group is the largest, showing an average increase of around 6% compared to that of the 0.50 mm group. Additionally, Linearity E also decreased, with a minimum of 1.07% in the 0.65 mm group, significantly lower than the 3.33% in the 0.50 mm group. Furthermore, the pressure loss increased slightly, with the 0.65 mm group having the largest pressure loss; however, at a flow rate of 1600 L/h, the pressure loss only increases by 0.186 kPa compared to that of the 0.50 mm group. Flow field analysis reveals that changes in axial clearance predominantly affect pressure distribution. Larger clearances reduce low-pressure regions on upstream and downstream transition surfaces, thereby reducing energy loss due to pressure changes. Entropy analysis further demonstrates that higher axial clearance decreases energy loss in the upstream and downstream stationary domains, optimizing the DRT-FM’s energy characteristics.


  • Open Access

    Investigation of Cavitation Flow and Entropy Production Characteristics in a Dual-Rotor Turbine Flowmeter

    by Jiabao Liu, Zhibin Zhang, Bing Wang, Yuxiang Han, Fuji Huang, Mantang Chen, Hao Zan

    Flow meters are extensively utilized in fields such as chemical engineering, petroleum, and aerospace, and are an indispensable component of modern industry. This paper examines the metrological properties of a dual-rotor turbine flow meter within its measurable flow range through experimental approaches and investigates the cavitation flow dynamics within the flow meter using numerical methods. First, the flow characteristics curve of the dual-rotor turbine flow meter was established experimentally, and the accuracy of numerical simulation results was validated. Secondly, the transient characteristics of the cavitation cavity were revealed using the Z-G-B cavitation model and dynamic mesh technology. Finally, entropy production theory was applied to investigate the energy losses caused by cavitation, analyzing the contributions of different types of energy losses during the cavitation process. Flow calibration experiments and numerical simulations reveal an increase in the meter coefficient of the dual-rotor turbine flow meter in high-flow cavitation zones, indicating that the displayed flow rate is slightly higher during cavitation compared to non-cavitating flows. Transient cavitation flow undergoes three stages: attachment, development, and collapse. At 323 K, the volume fractions of upstream and downstream cavities increase by 38.9% and 48.3%, respectively, with the cavitation cycle duration being 1.21 times that at 298 K. At 343 K, these increases are 75.3% and 239.2%, with the cycle duration being 2.63 times that at 298 K. Among the various sources of loss, the contribution from losses due to pulsating velocity gradients is the most significant, with maximum proportions of 81.95%, 85.1%, and 87.11% at 298 K, 323 K, and 343 K, respectively.