Naveen Guruprasad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Naveen Guruprasad has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- John van der Schaaf
Technische Universiteit Eindhoven
3 shared publications - Matheus Theodorus de Groot
Department of Chemical Engineering and Chemistry, Sustainable Process Engineering Group, Eindhoven University of Technology, Eindhoven, 5600 MB, The Netherlands
3 shared publications
Latest Publications
- Open Access
- 11 November 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (21) , 214508
Hydrogen Crossover in AEM Water Electrolysis: Influence of Cell Architecture and Catalyst Layer Supersaturation
Hydrogen gas crossover limits part-load flexibility and pressurized operation of anion exchange membrane water electrolysis. This phenomenon is often attributed to the membrane properties, while the influence of cell architecture remains poorly quantified. In this work, two zero-gap cells (a commercial Baltic flow cell and a 3D printed diagnostic cell) with identical membrane electrode assembly (MEA) were tested in 1 M KOH at 25 °C and 60 °C to isolate the effect of cell topology. A 1D transport model was further developed to isolate the contributions of membrane and dissolved hydrogen supersaturation at the catalyst layer to the measured crossover flux. The two cells showed a 2.9 fold difference in crossover, which was attributed to differences in catalyst-layer supersaturation. Comparison with independently reported data for the same commercial platform operated with a hydrophobic carbon gas diffusion electrode at the cathode, shows a further reduction of crossover by more than an order of magnitude. Across the published PEM and alkaline studies the catalyst-layer supersaturation varies by at least two orders of magnitude. A Pt/C recombination layer reduced crossover by 40%, but with the voltage penalty of 230 mV. Cathode redesign can therefore substantially reduce crossover using existing membranes, without adding any significant efficiency penalty.
- 11 November 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (21) , 214508
Open AccessHydrogen Crossover in AEM Water Electrolysis: Influence of Cell Architecture and Catalyst Layer Supersaturation
Hydrogen gas crossover limits part-load flexibility and pressurized operation of anion exchange membrane water electrolysis. This phenomenon is often attributed to the membrane properties, while the influence of cell architecture remains poorly quantified. In this work, two zero-gap cells (a commercial Baltic flow cell and a 3D printed diagnostic cell) with identical membrane electrode assembly (MEA) were tested in 1 M KOH at 25 °C and 60 °C to isolate the effect of cell topology. A 1D transport model was further developed to isolate the contributions of membrane and dissolved hydrogen supersaturation at the catalyst layer to the measured crossover flux. The two cells showed a 2.9 fold difference in crossover, which was attributed to differences in catalyst-layer supersaturation. Comparison with independently reported data for the same commercial platform operated with a hydrophobic carbon gas diffusion electrode at the cathode, shows a further reduction of crossover by more than an order of magnitude. Across the published PEM and alkaline studies the catalyst-layer supersaturation varies by at least two orders of magnitude. A Pt/C recombination layer reduced crossover by 40%, but with the voltage penalty of 230 mV. Cathode redesign can therefore substantially reduce crossover using existing membranes, without adding any significant efficiency penalty.
- Open Access
- 11 February 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (3) , 034505
Elucidating the Role of Catalyst Layer Resistance in AEM Water Electrolysis
Enhancing catalyst-layer efficiency and durability at high current densities is essential for scalable electrolyzer deployment. Unlike proton exchange membrane systems that are dominated by anodic losses, anion exchange membrane (AEM) systems can exhibit catalyst layer resistances at both electrodes, warranting the use of reference electrodes for kinetic decoupling. We present a methodology to quantify catalyst layer resistance, utilization heterogeneity, and transport limitations (ionic or electronic) by means of impedance diagnostics with dual reference electrodes integrated in the flow channels of each half-cell. Under nominal catalyst loading, we observed elevated local current densities near the membrane anode catalyst interface, implicating ionic conductivity as the primary cause. For the cathode, electronic resistance seems to be limiting. Combined, they manifest as an additional 50–80 mV overpotential attributable to the catalyst layer, a non-negligible fraction of the total 1.9 V of cell voltage at 2 A cm −2 . Reducing the catalyst loading improved the reaction homogeneity at the anode; however, for the cathode, it resulted in a marked decrease in effective electronic conductivity, which exacerbated the spatial heterogeneity and further elevated the cathodic kinetic overpotential. These findings highlight the need for designing and evaluating catalyst layer morphologies for balanced electrochemical activity and efficiency.
- 11 February 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (3) , 034505
Open AccessElucidating the Role of Catalyst Layer Resistance in AEM Water Electrolysis
Enhancing catalyst-layer efficiency and durability at high current densities is essential for scalable electrolyzer deployment. Unlike proton exchange membrane systems that are dominated by anodic losses, anion exchange membrane (AEM) systems can exhibit catalyst layer resistances at both electrodes, warranting the use of reference electrodes for kinetic decoupling. We present a methodology to quantify catalyst layer resistance, utilization heterogeneity, and transport limitations (ionic or electronic) by means of impedance diagnostics with dual reference electrodes integrated in the flow channels of each half-cell. Under nominal catalyst loading, we observed elevated local current densities near the membrane anode catalyst interface, implicating ionic conductivity as the primary cause. For the cathode, electronic resistance seems to be limiting. Combined, they manifest as an additional 50–80 mV overpotential attributable to the catalyst layer, a non-negligible fraction of the total 1.9 V of cell voltage at 2 A cm −2 . Reducing the catalyst loading improved the reaction homogeneity at the anode; however, for the cathode, it resulted in a marked decrease in effective electronic conductivity, which exacerbated the spatial heterogeneity and further elevated the cathodic kinetic overpotential. These findings highlight the need for designing and evaluating catalyst layer morphologies for balanced electrochemical activity and efficiency.
- Open Access
- 13 June 2024
- Published by Elsevier in Journal of Power Sources
- Vol. 613
Unraveling the impact of reverse currents on electrode stability in anion exchange membrane water electrolysis
- 13 June 2024
- Published by Elsevier in Journal of Power Sources
- Vol. 613
Open AccessUnraveling the impact of reverse currents on electrode stability in anion exchange membrane water electrolysis