Mohammad Junaid
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mohammad Junaid has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Mahmud- Or- Rashid
Department of Mechanical Engineering, Shahjalal University of Science and Technology, Sylhet, 3114, Bangladesh
2 shared publicationsAbul Mukid Mohammad Mukaddes
Department of Industrial and Production Engineering, Shahjalal University of Science and Technology, Sylhet, 3114, Bangladesh
1 shared publicationAhsan-Us-Sadique Sadique
1 shared publicationFarhan Chowdhury Ruhel
Department of Mechanical Engineering, Shahjalal University of Science and Technology, Sylhet-3114, Bangladesh
1 shared publicationPabel Shahrear
Department of Mathematics, Shahjalal University of Science and Technology, Sylhet-3114, Bangladesh
1 shared publication- Pabel Shahrear
Shahjalal University of Science and Technology
1 shared publication
Latest Publications
- Open Access
- 5 May 2026
- Published by Elsevier in SSRN Electronic Journal
Enhancing Durability of Cast Iron Cylinder Liners through Normalizing: Hardness, Thermal Conductivity, and Wear Analysis
Cylinder liners play a vital role in internal combustion engines by governing wear resistance, heat transfer, and mechanical stability. This study evaluates the effect of normalizing heat treatment on gray cast iron liners used in Toyota 1HZ diesel engines deployed in Bangladesh Army vehicles. Liners were normalized at 910 °C with controlled cooling, followed by systematic hardness, thermal conductivity, and wear–deformation tests under both laboratory and real engine conditions.,Results demonstrated that normalizing reduced hardness from 283 to 166 BHN (41.4% decrease), improving ductility and lowering the risk of brittle cracking. Thermal conductivity increased from 49 W/m.K in untreated liners to 68 W/m.K after normalizing, a 38.8% improvement that facilitated faster heat dissipation and reduced thermal stresses. Wear analysis revealed a marked improvement in thickness uniformity: untreated liners exhibited 10.7% non-uniformity, while normalized liners showed only 2.2%, corresponding to an 80% reduction in wear variation. Microstructural observations confirmed refinement of coarse pearlite into fine, evenly distributed pearlite, which underpinned these property changes.,The findings highlight a practical trade-off: while higher conductivity may slightly reduce thermal efficiency by accelerating heat rejection, the overall durability, ductility, and wear uniformity of normalized liners are significantly enhanced. For military and heavy-duty applications where reliability is critical, normalizing emerges as a cost-effective treatment that extends service life compared to untreated liners and offers a feasible alternative to expensive coatings or advanced alloys.
- 5 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEnhancing Durability of Cast Iron Cylinder Liners through Normalizing: Hardness, Thermal Conductivity, and Wear Analysis
Cylinder liners play a vital role in internal combustion engines by governing wear resistance, heat transfer, and mechanical stability. This study evaluates the effect of normalizing heat treatment on gray cast iron liners used in Toyota 1HZ diesel engines deployed in Bangladesh Army vehicles. Liners were normalized at 910 °C with controlled cooling, followed by systematic hardness, thermal conductivity, and wear–deformation tests under both laboratory and real engine conditions.,Results demonstrated that normalizing reduced hardness from 283 to 166 BHN (41.4% decrease), improving ductility and lowering the risk of brittle cracking. Thermal conductivity increased from 49 W/m.K in untreated liners to 68 W/m.K after normalizing, a 38.8% improvement that facilitated faster heat dissipation and reduced thermal stresses. Wear analysis revealed a marked improvement in thickness uniformity: untreated liners exhibited 10.7% non-uniformity, while normalized liners showed only 2.2%, corresponding to an 80% reduction in wear variation. Microstructural observations confirmed refinement of coarse pearlite into fine, evenly distributed pearlite, which underpinned these property changes.,The findings highlight a practical trade-off: while higher conductivity may slightly reduce thermal efficiency by accelerating heat rejection, the overall durability, ductility, and wear uniformity of normalized liners are significantly enhanced. For military and heavy-duty applications where reliability is critical, normalizing emerges as a cost-effective treatment that extends service life compared to untreated liners and offers a feasible alternative to expensive coatings or advanced alloys.
- 1 August 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (8)
Impact of bifurcation angle on hemodynamics and oxygen delivery in stenosed arterial junctions
Cardiovascular diseases, largely driven by atherosclerosis-induced stenosis, remain the leading cause of mortality worldwide. The bifurcation of the brachiocephalic trunk into the subclavian and common carotid arteries is particularly susceptible to disturbed hemodynamics and plaque accumulation. This study presents a computational analysis of the impact of stenosis and bifurcation geometry (45°, 60°, and 75°) on blood flow and oxygen transport using COMSOL Multiphysics®. Pulsatile flow conditions were modeled with coupled laminar flow and transport of diluted species modules to evaluate velocity, wall shear stress (WSS), and oxygen concentration. Results show that stenosis leads to a significant increase in peak systolic velocity (up to ∼31%) and localized WSS (peaking at 16 Pa), especially at lower bifurcation angles. Wider bifurcation geometries (75°) resulted in pronounced flow separation, vortex formation, and reduced oxygen delivery, with concentrations falling as low as 0.10 mol/m 3 in critical downstream regions. These hemodynamic disturbances were most severe in the presence of both wide bifurcation angles and stenotic narrowing. The model was validated against previous numerical and experimental studies, confirming its accuracy. The findings underscore the importance of considering arterial geometry in diagnosing vascular risk and optimizing intervention strategies. Integrating hemodynamic and oxygen transport analysis provides a more comprehensive understanding of stenosis progression and offers a foundation for personalized cardiovascular treatments.
- 1 August 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (8)
Impact of bifurcation angle on hemodynamics and oxygen delivery in stenosed arterial junctions
Cardiovascular diseases, largely driven by atherosclerosis-induced stenosis, remain the leading cause of mortality worldwide. The bifurcation of the brachiocephalic trunk into the subclavian and common carotid arteries is particularly susceptible to disturbed hemodynamics and plaque accumulation. This study presents a computational analysis of the impact of stenosis and bifurcation geometry (45°, 60°, and 75°) on blood flow and oxygen transport using COMSOL Multiphysics®. Pulsatile flow conditions were modeled with coupled laminar flow and transport of diluted species modules to evaluate velocity, wall shear stress (WSS), and oxygen concentration. Results show that stenosis leads to a significant increase in peak systolic velocity (up to ∼31%) and localized WSS (peaking at 16 Pa), especially at lower bifurcation angles. Wider bifurcation geometries (75°) resulted in pronounced flow separation, vortex formation, and reduced oxygen delivery, with concentrations falling as low as 0.10 mol/m 3 in critical downstream regions. These hemodynamic disturbances were most severe in the presence of both wide bifurcation angles and stenotic narrowing. The model was validated against previous numerical and experimental studies, confirming its accuracy. The findings underscore the importance of considering arterial geometry in diagnosing vascular risk and optimizing intervention strategies. Integrating hemodynamic and oxygen transport analysis provides a more comprehensive understanding of stenosis progression and offers a foundation for personalized cardiovascular treatments.
- Open Access
- 27 March 2025
- Published by Akademia Baru Publishing in Journal of Advanced Research in Numerical Heat Transfer
- Vol. 31 (1) , 126-150
Removal of Fungal Pathogens from Fingernails through Hyperthermal Treatments: A Mathematical Foundation in the Field of Computational Perspective
Onychomycosis (OM) afflicts a staggering 2% to 13% of the global populace, casting a long shadow over quality of life. Traditional treatments, be they systemic or topical, are fraught with challenges like poor permeability and undesirable side effects. In this groundbreaking study, we explore the mystical realm of natural hyperthermal treatments, specifically the mesmerizing dance of stepwise hot water and heated contact disks, as a novel remedy for OM. Harnessing the sophisticated wizardry of COMSOL Multiphysics®, we conjured a lifelike human figure nail model, comprising the nail plate, nail bed, and inner muscle layers. Through this intricate simulation, we meticulously observed nail temperatures during thermal applications, set at the enchanting heats of 70°C, 80°C, 90°C, and 100°C, thereby mapping out temperature profiles and deciphering the secrets of heat propagation. The results of this inquiry are nothing short of magical: stepwise hyperthermal treatments summon peak temperatures within the nail plate, powerful enough to vanquish fungal foes while preserving the sanctity of surrounding tissues. Intriguingly, our findings elevate hot water treatments as the supreme choice, proving more potent and safer than their hot disk counterparts for the treatment of onychomycosis-ravaged nails. Furthermore, for the soothing aftercare of these hyperthermal sessions, the gentle caress of running water at an optimal temperature significantly enhances patient comfort and diminishes the risk of thermal harm. This exotic approach not only unveils a cost-effective and accessible alternative to conventional OM therapies but also holds the enchanting promise of home-based administration, liberating patients from the clutches of medical expenses. This method heralds a spectacular evolution in the treatment of onychomycosis, blending scientific marvel with practical enchantment.
- 27 March 2025
- Published by Akademia Baru Publishing in Journal of Advanced Research in Numerical Heat Transfer
- Vol. 31 (1) , 126-150
Open AccessRemoval of Fungal Pathogens from Fingernails through Hyperthermal Treatments: A Mathematical Foundation in the Field of Computational Perspective
Onychomycosis (OM) afflicts a staggering 2% to 13% of the global populace, casting a long shadow over quality of life. Traditional treatments, be they systemic or topical, are fraught with challenges like poor permeability and undesirable side effects. In this groundbreaking study, we explore the mystical realm of natural hyperthermal treatments, specifically the mesmerizing dance of stepwise hot water and heated contact disks, as a novel remedy for OM. Harnessing the sophisticated wizardry of COMSOL Multiphysics®, we conjured a lifelike human figure nail model, comprising the nail plate, nail bed, and inner muscle layers. Through this intricate simulation, we meticulously observed nail temperatures during thermal applications, set at the enchanting heats of 70°C, 80°C, 90°C, and 100°C, thereby mapping out temperature profiles and deciphering the secrets of heat propagation. The results of this inquiry are nothing short of magical: stepwise hyperthermal treatments summon peak temperatures within the nail plate, powerful enough to vanquish fungal foes while preserving the sanctity of surrounding tissues. Intriguingly, our findings elevate hot water treatments as the supreme choice, proving more potent and safer than their hot disk counterparts for the treatment of onychomycosis-ravaged nails. Furthermore, for the soothing aftercare of these hyperthermal sessions, the gentle caress of running water at an optimal temperature significantly enhances patient comfort and diminishes the risk of thermal harm. This exotic approach not only unveils a cost-effective and accessible alternative to conventional OM therapies but also holds the enchanting promise of home-based administration, liberating patients from the clutches of medical expenses. This method heralds a spectacular evolution in the treatment of onychomycosis, blending scientific marvel with practical enchantment.