Kwang-Am Moon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kwang-Am Moon has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Hwi-Ung Choi
Department of Refrigeration and Air-Conditioning Engineering, Chonnam National University, Yeosu 59626, Republic of Korea
4 shared publications - Seong-Bhin Kim
Department of Mechanical Engineering, Ulsan National Institute of Science and Technology, Ulsan 44919, Republic of Korea
3 shared publications - Byeong-Hwa An
Department of Refrigeration and Air-Conditioning Engineering, Chonnam National University, Yeosu 59626, Republic of Korea
2 shared publications - Kwang-Hwan Choi
Department of Refrigeration and Air-Conditioning Engineering, Pukyong National University, Busan 48513, Republic of Korea
2 shared publications - Eflita Yohana
Department of Mechanical Engineering, Diponegoro University, Jl. Prof. Sudharto, SH, Semarang 50275, Indonesia
1 shared publication
Latest Publications
- Open Access
CFD Analysis of the Thermal-Hydraulic Performance in a Fin Channel of a Solar Air Heater with Various Block Shapes
A solar air heater generates heated air using solar energy. This system has a relatively simple design, which reduces the initial cost and facilitates maintenance compared with other solar systems. However, its thermal conversion efficiency is limited by the poor thermal conductivity of air. Previous studies have improved thermal efficiency by enhancing either the heat transfer area or the heat transfer coefficient, but most have applied only one of these approaches. In this work, a novel solar air heater with longitudinal fins and blocks, designed to simultaneously enhance the heat transfer area and heat transfer coefficient, is investigated for various block shapes (rectangular, forward-chamfered, backward-chamfered, and triangular blocks) utilizing computational fluid dynamics. Compared to the smooth fin channel, heat transfer is enhanced by a maximum of 1.61 times with the backward-chamfered block, while the corresponding enhancement factors for the rectangular, forward-chamfered, and triangular blocks are 1.52, 1.46, and 1.54, respectively. The thermo-hydraulic performance parameter, which simultaneously evaluates heat transfer augmentation and frictional penalty, further indicates that the backward-chamfered block is most effective at Reynolds numbers below 6000, while the rectangular block performs best above 9000.
Open AccessCFD Analysis of the Thermal-Hydraulic Performance in a Fin Channel of a Solar Air Heater with Various Block Shapes
A solar air heater generates heated air using solar energy. This system has a relatively simple design, which reduces the initial cost and facilitates maintenance compared with other solar systems. However, its thermal conversion efficiency is limited by the poor thermal conductivity of air. Previous studies have improved thermal efficiency by enhancing either the heat transfer area or the heat transfer coefficient, but most have applied only one of these approaches. In this work, a novel solar air heater with longitudinal fins and blocks, designed to simultaneously enhance the heat transfer area and heat transfer coefficient, is investigated for various block shapes (rectangular, forward-chamfered, backward-chamfered, and triangular blocks) utilizing computational fluid dynamics. Compared to the smooth fin channel, heat transfer is enhanced by a maximum of 1.61 times with the backward-chamfered block, while the corresponding enhancement factors for the rectangular, forward-chamfered, and triangular blocks are 1.52, 1.46, and 1.54, respectively. The thermo-hydraulic performance parameter, which simultaneously evaluates heat transfer augmentation and frictional penalty, further indicates that the backward-chamfered block is most effective at Reynolds numbers below 6000, while the rectangular block performs best above 9000.
- Open Access
Analysis of Heat Transfer and Fluid Flow in a Solar Air Heater with Sequentially Placed Rectangular Obstacles on the Fin Surface
A solar air heater (SAH) converts solar energy into heated air without causing environmental pollution. It features a low initial cost and easy maintenance due to its simple design. However, owing to air’s poor thermal conductivity, its thermal efficiency is relatively low compared to that of other solar systems. To improve its thermal performance, previous studies have aimed at either enlarging the heat transfer surface or increasing the convective heat transfer coefficient. In this study, a novel SAH with fins and sequentially placed obstacles on the fin surface—designed to achieve both surface extension through a finned channel and enhancement of the heat transfer coefficient via the obstacles—was investigated using computational fluid dynamics analysis. The results confirmed that the obstacles enhanced heat transfer performance by up to 2.602 times in the finned channel. However, the obstacles also caused a pressure loss. Therefore, the thermo-hydraulic performance was discussed, and it was concluded that the obstacles with a relative height of 0.12 and a relative pitch of 10 yielded the maximum THP values among the investigated conditions. Additionally, correlations for the Nusselt number and friction factor were derived and predicted the simulation values with good agreement.
Open AccessAnalysis of Heat Transfer and Fluid Flow in a Solar Air Heater with Sequentially Placed Rectangular Obstacles on the Fin Surface
A solar air heater (SAH) converts solar energy into heated air without causing environmental pollution. It features a low initial cost and easy maintenance due to its simple design. However, owing to air’s poor thermal conductivity, its thermal efficiency is relatively low compared to that of other solar systems. To improve its thermal performance, previous studies have aimed at either enlarging the heat transfer surface or increasing the convective heat transfer coefficient. In this study, a novel SAH with fins and sequentially placed obstacles on the fin surface—designed to achieve both surface extension through a finned channel and enhancement of the heat transfer coefficient via the obstacles—was investigated using computational fluid dynamics analysis. The results confirmed that the obstacles enhanced heat transfer performance by up to 2.602 times in the finned channel. However, the obstacles also caused a pressure loss. Therefore, the thermo-hydraulic performance was discussed, and it was concluded that the obstacles with a relative height of 0.12 and a relative pitch of 10 yielded the maximum THP values among the investigated conditions. Additionally, correlations for the Nusselt number and friction factor were derived and predicted the simulation values with good agreement.
- Open Access
Experimental Study on the Performance of an Air Conditioning Unit with a Baffled Indirect Evaporative Cooler
Indirect evaporative coolers (IECs) use the latent heat of water evaporation to cool air. This system has the advantage of operating at low power without a compressor and does not increase the absolute humidity of the air. However, an IEC is difficult to use on its own because its cooling capacity is limited by the theoretical constraint of the wet-bulb temperature of the ambient air. Therefore, an air conditioning unit (ACU) was integrated with an IEC and experimentally evaluated in this study. The dry and wet channels of the IEC were integrated with an ACU evaporator and a condenser, unlike previous studies where IECs were integrated solely with either an evaporator or a condenser. This reduced the cooling load on the evaporator and helped the condenser to dissipate heat to improve the performance of the existing ACU. In addition, the IEC was equipped with baffles to improve its performance. To assess the extent of the performance improvement due to integration with the IEC, comparisons were also performed under the same experimental conditions with an ACU only. The results showed that under conditions with an indoor temperature of 32 °C, integrating the IEC with the ACU increased the average cooling capacity by 13.1% and decreased the average power consumption by 8.60% during the test period, compared to using only the ACU. Consequently, the average coefficient of performance (COP) increased by 19.5% compared to using only the ACU under the same conditions.
Open AccessExperimental Study on the Performance of an Air Conditioning Unit with a Baffled Indirect Evaporative Cooler
Indirect evaporative coolers (IECs) use the latent heat of water evaporation to cool air. This system has the advantage of operating at low power without a compressor and does not increase the absolute humidity of the air. However, an IEC is difficult to use on its own because its cooling capacity is limited by the theoretical constraint of the wet-bulb temperature of the ambient air. Therefore, an air conditioning unit (ACU) was integrated with an IEC and experimentally evaluated in this study. The dry and wet channels of the IEC were integrated with an ACU evaporator and a condenser, unlike previous studies where IECs were integrated solely with either an evaporator or a condenser. This reduced the cooling load on the evaporator and helped the condenser to dissipate heat to improve the performance of the existing ACU. In addition, the IEC was equipped with baffles to improve its performance. To assess the extent of the performance improvement due to integration with the IEC, comparisons were also performed under the same experimental conditions with an ACU only. The results showed that under conditions with an indoor temperature of 32 °C, integrating the IEC with the ACU increased the average cooling capacity by 13.1% and decreased the average power consumption by 8.60% during the test period, compared to using only the ACU. Consequently, the average coefficient of performance (COP) increased by 19.5% compared to using only the ACU under the same conditions.
- Open Access
Experimental Study on the Heat Pump Performance Combined with Dual-Purpose Solar Collector
In this study, we proposed and experimentally investigated a novel solar-assisted heat pump (SAHP) system integrated with a dual-purpose solar collector (DPSC). The DPSC is a solar collector designed to produce both heated air and hot water, and the proposed configuration of the SAHP utilizes both heated air and water simultaneously to improve the performance of the heat pump. The experiment was conducted under natural weather conditions on a clear day. The performance of the proposed system was evaluated and compared to that of a conventional air-type SAHP system. The results showed that the coefficient of performance (COP) of the proposed system, which takes into account the performance of the DPSC, heat pump, and the power consumption of both the blower and pump, was 3.14. In contrast, the system COP of the SAHP operated as conventional air-type SAHP was 2.33. This finding clearly demonstrated that the proposed SAHP performed better than the traditional SAHP mode. Additionally, the results of this research are useful as fundamental data related to SAHP combined with DPSC.
Open AccessExperimental Study on the Heat Pump Performance Combined with Dual-Purpose Solar Collector
In this study, we proposed and experimentally investigated a novel solar-assisted heat pump (SAHP) system integrated with a dual-purpose solar collector (DPSC). The DPSC is a solar collector designed to produce both heated air and hot water, and the proposed configuration of the SAHP utilizes both heated air and water simultaneously to improve the performance of the heat pump. The experiment was conducted under natural weather conditions on a clear day. The performance of the proposed system was evaluated and compared to that of a conventional air-type SAHP system. The results showed that the coefficient of performance (COP) of the proposed system, which takes into account the performance of the DPSC, heat pump, and the power consumption of both the blower and pump, was 3.14. In contrast, the system COP of the SAHP operated as conventional air-type SAHP was 2.33. This finding clearly demonstrated that the proposed SAHP performed better than the traditional SAHP mode. Additionally, the results of this research are useful as fundamental data related to SAHP combined with DPSC.