Joana Pinheiro Martins
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Joana Pinheiro Martins has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- António Augusto Fernandes
LAETA, INEGI, Campus da FEUP, R. Dr. Roberto Frias 400, 4200-465 Porto, Portugal
7 shared publications - Elisabete Silva
LAETA, INEGI, 4200-465 Porto, Portugal
7 shared publications - Fábio Pinheiro
LAETA, INEGI, Campus da FEUP, R. Dr. Roberto Frias 400, 4200-465 Porto, Portugal
4 shared publications - Maria Francisca Vaz
LAETA, INEGI, Campus da FEUP Rua Dr. Roberto Frias 400, 4200-465 Porto, Portugal
4 shared publications - Nuno Miguel Ferreira
LAETA, INEGI, 4200-465 Porto, Portugal
4 shared publications - Ana Telma Silva
LAETA, INEGI, Campus da FEUP Rua Dr. Roberto Frias 400, 4200-465 Porto, Portugal
3 shared publications
Latest Publications
- Open Access
Melt Electrowriting-Based Hybrid Fabrication of Biodegradable Cog Threads: Design and Mechanical Evaluation for Pelvic Floor Repair
Additive manufacturing (AM) offers new opportunities for biomedical device design; however, its translation to soft-tissue reinforcement remains challenging, particularly in pelvic organ prolapse (POP) applications requiring mechanical performance and tissue compatibility. In this study, a hybrid AM approach combining melt electrowriting (MEW) and controlled post-processing was developed to fabricate biodegradable poly(ε-caprolactone) (PCL) cog threads for minimally invasive pelvic reinforcement. This integrated fabrication workflow enables the precise deposition of microscale fibers via MEW followed by localized mechanical modification, offering a versatile platform for tailoring graft architecture and anchoring geometry. Smooth filaments were first produced via MEW and subsequently post-processed to introduce barbs for mechanical anchorage. The resulting structures were mechanically characterized through uniaxial tensile testing and evaluated as reinforcement elements in ex vivo sow vaginal tissue using ball burst testing. The MEW-fabricated cog threads increased the ultimate load of vaginal tissue from 83 ± 20 N (control) to 126 ± 15 N, corresponding to a 51.8% improvement (p = 0.0477). Compared with commercial PCL cog threads reported in the literature (177.0 ± 5.4 N), the reinforced specimens achieved approximately 71% of the benchmark load. Owing to their intermediate stiffness profile, the MEW-fabricated cog threads reduced mechanical mismatch with soft tissue compared to high-stiffness commercial alternatives. These findings demonstrate the feasibility of hybrid MEW-based additive manufacturing strategies for engineering mechanically compatible, application-driven soft-tissue reinforcement systems.
Open AccessMelt Electrowriting-Based Hybrid Fabrication of Biodegradable Cog Threads: Design and Mechanical Evaluation for Pelvic Floor Repair
Additive manufacturing (AM) offers new opportunities for biomedical device design; however, its translation to soft-tissue reinforcement remains challenging, particularly in pelvic organ prolapse (POP) applications requiring mechanical performance and tissue compatibility. In this study, a hybrid AM approach combining melt electrowriting (MEW) and controlled post-processing was developed to fabricate biodegradable poly(ε-caprolactone) (PCL) cog threads for minimally invasive pelvic reinforcement. This integrated fabrication workflow enables the precise deposition of microscale fibers via MEW followed by localized mechanical modification, offering a versatile platform for tailoring graft architecture and anchoring geometry. Smooth filaments were first produced via MEW and subsequently post-processed to introduce barbs for mechanical anchorage. The resulting structures were mechanically characterized through uniaxial tensile testing and evaluated as reinforcement elements in ex vivo sow vaginal tissue using ball burst testing. The MEW-fabricated cog threads increased the ultimate load of vaginal tissue from 83 ± 20 N (control) to 126 ± 15 N, corresponding to a 51.8% improvement (p = 0.0477). Compared with commercial PCL cog threads reported in the literature (177.0 ± 5.4 N), the reinforced specimens achieved approximately 71% of the benchmark load. Owing to their intermediate stiffness profile, the MEW-fabricated cog threads reduced mechanical mismatch with soft tissue compared to high-stiffness commercial alternatives. These findings demonstrate the feasibility of hybrid MEW-based additive manufacturing strategies for engineering mechanically compatible, application-driven soft-tissue reinforcement systems.
- Open Access
- 28 August 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (17) , 9436
Mechanical Characterization and Azithromycin Coating of Melt Electrowritten Polycaprolactone Mesh Implants for Prolapse Repair
Pelvic organ prolapse (POP) cases have been rising, affecting women’s quality of life. Severe cases often require surgical mesh implants, which can cause complications like tissue erosion and infection, leading the FDA to ban transvaginal meshes for POP. To address this, polycaprolactone (PCL) mesh implants, produced via melt electrowriting (MEW), were evaluated mechanically and coated with azithromycin, an antibiotic for genitourinary infections. Uniaxial tensile and cyclic tests assessed the long-term behavior of the meshes over 100 cycles. The results show that while all PCL meshes had similar behavior, those with 1 mm pores sustained higher stress, whereas 1.5 mm pore size meshes had mechanical properties closer to vaginal tissue but remained stiffer. Cyclic tests revealed initial damage and hardening during plastic deformation, with tensile tests confirming increased stiffness, as Young’s modulus rose between 19.2% and 29.3%. Zone inhibition and biofilm assays evaluated azithromycin’s effectiveness against bacterial infection. Even though FTIR analysis could not confirm antibiotic incorporation, the drug coated meshes show inhibitory activity against E. coli biofilm formation and MSSA in its planktonic state. Scanning Electron Microscopy supported these findings. These results suggest that MEW-fabricated PCL meshes coated with azithromycin hold promise as improved implants for POP treatment.
- 28 August 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (17) , 9436
Open AccessMechanical Characterization and Azithromycin Coating of Melt Electrowritten Polycaprolactone Mesh Implants for Prolapse Repair
Pelvic organ prolapse (POP) cases have been rising, affecting women’s quality of life. Severe cases often require surgical mesh implants, which can cause complications like tissue erosion and infection, leading the FDA to ban transvaginal meshes for POP. To address this, polycaprolactone (PCL) mesh implants, produced via melt electrowriting (MEW), were evaluated mechanically and coated with azithromycin, an antibiotic for genitourinary infections. Uniaxial tensile and cyclic tests assessed the long-term behavior of the meshes over 100 cycles. The results show that while all PCL meshes had similar behavior, those with 1 mm pores sustained higher stress, whereas 1.5 mm pore size meshes had mechanical properties closer to vaginal tissue but remained stiffer. Cyclic tests revealed initial damage and hardening during plastic deformation, with tensile tests confirming increased stiffness, as Young’s modulus rose between 19.2% and 29.3%. Zone inhibition and biofilm assays evaluated azithromycin’s effectiveness against bacterial infection. Even though FTIR analysis could not confirm antibiotic incorporation, the drug coated meshes show inhibitory activity against E. coli biofilm formation and MSSA in its planktonic state. Scanning Electron Microscopy supported these findings. These results suggest that MEW-fabricated PCL meshes coated with azithromycin hold promise as improved implants for POP treatment.
- Open Access
Development and Simulation-Based Validation of Biodegradable 3D-Printed Cog Threads for Pelvic Organ Prolapse Repair
Pelvic organ prolapse (POP) is a prevalent condition, affecting women all over the world, and is commonly treated through surgical interventions that present limitations such as recurrence or complications associated with synthetic meshes. In this study, biodegradable poly(-caprolactone) (PCL) cog threads are proposed as a minimally invasive alternative for vaginal wall reinforcement. A custom cutting tool was developed to fabricate threads with varying barb angles (90°, 75°, 60°, and 45°), which were produced via Melt Electrowriting. Their mechanical behavior was assessed through uniaxial tensile tests and validated using finite element simulations. The results showed that barb orientation had minimal influence on tensile performance. In simulations of anterior vaginal wall deformation under cough pressure, all cog thread configurations significantly reduced displacement in the damaged tissue model, achieving values comparable to or even lower than those of healthy tissue. A ball burst simulation using an anatomically accurate model further demonstrated a 13% increase in reaction force with cog thread reinforcement. Despite fabrication limitations, this study supports the biomechanical potential of 3D-printed PCL cog threads for POP treatment, and lays the groundwork for future in vivo validation.Open AccessDevelopment and Simulation-Based Validation of Biodegradable 3D-Printed Cog Threads for Pelvic Organ Prolapse Repair
Pelvic organ prolapse (POP) is a prevalent condition, affecting women all over the world, and is commonly treated through surgical interventions that present limitations such as recurrence or complications associated with synthetic meshes. In this study, biodegradable poly(-caprolactone) (PCL) cog threads are proposed as a minimally invasive alternative for vaginal wall reinforcement. A custom cutting tool was developed to fabricate threads with varying barb angles (90°, 75°, 60°, and 45°), which were produced via Melt Electrowriting. Their mechanical behavior was assessed through uniaxial tensile tests and validated using finite element simulations. The results showed that barb orientation had minimal influence on tensile performance. In simulations of anterior vaginal wall deformation under cough pressure, all cog thread configurations significantly reduced displacement in the damaged tissue model, achieving values comparable to or even lower than those of healthy tissue. A ball burst simulation using an anatomically accurate model further demonstrated a 13% increase in reaction force with cog thread reinforcement. Despite fabrication limitations, this study supports the biomechanical potential of 3D-printed PCL cog threads for POP treatment, and lays the groundwork for future in vivo validation. - Open Access
Antibiotic-Coated Melt Electrowritten Polycaprolactone Meshes: Fabrication and In Vitro Antibacterial Evaluation
In recent years, pelvic organ prolapse (POP) cases have been rising, affecting women’s quality of life. Synthetic surgical transvaginal meshes used for POP treatment were withdrawn from the United States market in 2019 due to high risks, including infection, vaginal mesh erosion, and POP reoccurrence. Biodegradable mesh implants with three-dimensional printing technology have emerged as an innovative alternative. In this study, polycaprolactone (PCL) meshes for POP repair were fabricated using melt electrospinning writing (MEW) and mechanically evaluated through uniaxial tensile tests. Following this, they were coated with antibiotics—azithromycin, gentamicin sulfate, and ciprofloxacin—commonly used for genitourinary tract infections. Zone inhibition and biofilm assays evaluated antibiotic effectiveness in preventing mesh infections by Escherichia coli, and methicillin-susceptible (MSSA) and methicillin-resistant (MRSA) Staphylococcus aureus. The meshes presented a mechanical behavior closer to vaginal tissue than commercially available meshes. Fourier transform infrared analysis confirmed antibiotic incorporation. Ciprofloxacin demonstrated antibacterial activity against MRSA, with a 92% reduction in metabolic activity and a 99% biomass reduction. Gentamicin and ciprofloxacin displayed inhibitory activity against MSSA and E. coli. Scanning electron microscopy images support these conclusions. This methodology may offer a more effective, patient-friendly solution for POP repair, improving healing and the quality of life for affected women.
Open AccessAntibiotic-Coated Melt Electrowritten Polycaprolactone Meshes: Fabrication and In Vitro Antibacterial Evaluation
In recent years, pelvic organ prolapse (POP) cases have been rising, affecting women’s quality of life. Synthetic surgical transvaginal meshes used for POP treatment were withdrawn from the United States market in 2019 due to high risks, including infection, vaginal mesh erosion, and POP reoccurrence. Biodegradable mesh implants with three-dimensional printing technology have emerged as an innovative alternative. In this study, polycaprolactone (PCL) meshes for POP repair were fabricated using melt electrospinning writing (MEW) and mechanically evaluated through uniaxial tensile tests. Following this, they were coated with antibiotics—azithromycin, gentamicin sulfate, and ciprofloxacin—commonly used for genitourinary tract infections. Zone inhibition and biofilm assays evaluated antibiotic effectiveness in preventing mesh infections by Escherichia coli, and methicillin-susceptible (MSSA) and methicillin-resistant (MRSA) Staphylococcus aureus. The meshes presented a mechanical behavior closer to vaginal tissue than commercially available meshes. Fourier transform infrared analysis confirmed antibiotic incorporation. Ciprofloxacin demonstrated antibacterial activity against MRSA, with a 92% reduction in metabolic activity and a 99% biomass reduction. Gentamicin and ciprofloxacin displayed inhibitory activity against MSSA and E. coli. Scanning electron microscopy images support these conclusions. This methodology may offer a more effective, patient-friendly solution for POP repair, improving healing and the quality of life for affected women.
- Open Access
- 10 July 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (14) , 7763
Antistatic Melt-Electrowritten Biodegradable Mesh Implants for Enhanced Pelvic Organ Prolapse Repair
Pelvic organ prolapse (POP) is a health condition that can significantly impact patients’ quality of life. Unfortunately, most available treatments present drawbacks such as high recurrence rates, risk of complications, poor tissue integration, and the need for reintervention. One promising alternative is the use of biodegradable implantable meshes, which can support the organs, guide tissue regeneration, and be fully absorbed without damaging the surrounding tissues. In this study, biodegradable polycaprolactone (PCL) meshes were fabricated using melt electrowritten (MEW), incorporating the antistatic agent Hostastat® FA 38 (HT) to address these limitations. The goal was to produce microscaffolds with suitable biophysical properties, particularly more stable fiber deposition and reduced fiber diameter. Different HT concentrations (0.03, 0.06, and 0.1 wt%) were investigated to assess their influence on the fiber diameter and mechanical properties of the PCL meshes. Increasing HT concentration significantly reduced fiber diameter by 14–17%, 39–45%, and 65–66%, depending on mesh geometry (square or sinusoidal). At 0.06 wt%, PCL/HT meshes showed a 24.10% increase in tensile strength and a 55.59% increase in Young’s Modulus compared to pure PCL meshes of similar diameter. All formulations demonstrated cell viability >90%. Differential scanning calorimetry (DSC) revealed preserved thermal stability and changes in crystallinity with HT addition. These findings indicate that the antistatic agent yields promising results, enabling the production of thinner, more stable fibers with higher tensile strength and Young’s Modulus than PCL meshes, without adding cellular toxicity. Developing a thinner and more stable mesh that mimics vaginal tissue mechanics could offer an innovative solution for POP repair.
- 10 July 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (14) , 7763
Open AccessAntistatic Melt-Electrowritten Biodegradable Mesh Implants for Enhanced Pelvic Organ Prolapse Repair
Pelvic organ prolapse (POP) is a health condition that can significantly impact patients’ quality of life. Unfortunately, most available treatments present drawbacks such as high recurrence rates, risk of complications, poor tissue integration, and the need for reintervention. One promising alternative is the use of biodegradable implantable meshes, which can support the organs, guide tissue regeneration, and be fully absorbed without damaging the surrounding tissues. In this study, biodegradable polycaprolactone (PCL) meshes were fabricated using melt electrowritten (MEW), incorporating the antistatic agent Hostastat® FA 38 (HT) to address these limitations. The goal was to produce microscaffolds with suitable biophysical properties, particularly more stable fiber deposition and reduced fiber diameter. Different HT concentrations (0.03, 0.06, and 0.1 wt%) were investigated to assess their influence on the fiber diameter and mechanical properties of the PCL meshes. Increasing HT concentration significantly reduced fiber diameter by 14–17%, 39–45%, and 65–66%, depending on mesh geometry (square or sinusoidal). At 0.06 wt%, PCL/HT meshes showed a 24.10% increase in tensile strength and a 55.59% increase in Young’s Modulus compared to pure PCL meshes of similar diameter. All formulations demonstrated cell viability >90%. Differential scanning calorimetry (DSC) revealed preserved thermal stability and changes in crystallinity with HT addition. These findings indicate that the antistatic agent yields promising results, enabling the production of thinner, more stable fibers with higher tensile strength and Young’s Modulus than PCL meshes, without adding cellular toxicity. Developing a thinner and more stable mesh that mimics vaginal tissue mechanics could offer an innovative solution for POP repair.
- Open Access
- 23 October 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (21) , 9670
Medical- and Non-Medical-Grade Polycaprolactone Mesh Printing for Prolapse Repair: Establishment of Melt Electrowriting Prototype Parameters
Pelvic organ prolapse (POP) occurs due to inadequate support of female pelvic organs and is often treated with synthetic implants. However, complications like infections, mesh shrinkage, and tissue erosion can arise due to biomechanical incompatibilities with native tissue. This study aimed to optimize the melt electrowriting process using medical-grade biodegradable Poly(ε-caprolactone) (PCL) with a pellet extruder to print meshes that mimic the mechanical properties of vaginal tissue. Square and diagonal mesh designs with filament diameters of 80 µm, 160 µm, and 240 µm were produced and evaluated through mechanical testing, comparing them to a commercial mesh and sheep vaginal tissue. The results showed that when comparing medical-grade with non-medical-grade square meshes, there was a 54% difference in the Secant modulus, with the non-medical-grade meshes falling short of matching the properties of vaginal tissue. The square-shaped medical-grade PCL mesh closely approximated vaginal tissue, showing only a 13.7% higher Secant modulus and a maximum stress of 0.29 MPa, indicating strong performance. Although the diagonal-shaped mesh exhibited a 14% stress difference, its larger Secant modulus discrepancy of 45% rendered it less suitable. In contrast, the commercial mesh was significantly stiffer, measuring 77.5% higher than vaginal tissue. The diagonal-shaped mesh may better match the stress–strain characteristics of vaginal tissue, but the square-shaped mesh offers stronger support due to its higher stress–strain curve. Overall, meshes printed with medical-grade PCL show superior performance compared to non-medical-grade meshes, suggesting that they are a promising avenue for future advancements in the field of POP repair.
- 23 October 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (21) , 9670
Open AccessMedical- and Non-Medical-Grade Polycaprolactone Mesh Printing for Prolapse Repair: Establishment of Melt Electrowriting Prototype Parameters
Pelvic organ prolapse (POP) occurs due to inadequate support of female pelvic organs and is often treated with synthetic implants. However, complications like infections, mesh shrinkage, and tissue erosion can arise due to biomechanical incompatibilities with native tissue. This study aimed to optimize the melt electrowriting process using medical-grade biodegradable Poly(ε-caprolactone) (PCL) with a pellet extruder to print meshes that mimic the mechanical properties of vaginal tissue. Square and diagonal mesh designs with filament diameters of 80 µm, 160 µm, and 240 µm were produced and evaluated through mechanical testing, comparing them to a commercial mesh and sheep vaginal tissue. The results showed that when comparing medical-grade with non-medical-grade square meshes, there was a 54% difference in the Secant modulus, with the non-medical-grade meshes falling short of matching the properties of vaginal tissue. The square-shaped medical-grade PCL mesh closely approximated vaginal tissue, showing only a 13.7% higher Secant modulus and a maximum stress of 0.29 MPa, indicating strong performance. Although the diagonal-shaped mesh exhibited a 14% stress difference, its larger Secant modulus discrepancy of 45% rendered it less suitable. In contrast, the commercial mesh was significantly stiffer, measuring 77.5% higher than vaginal tissue. The diagonal-shaped mesh may better match the stress–strain characteristics of vaginal tissue, but the square-shaped mesh offers stronger support due to its higher stress–strain curve. Overall, meshes printed with medical-grade PCL show superior performance compared to non-medical-grade meshes, suggesting that they are a promising avenue for future advancements in the field of POP repair.
- Open Access
- 21 June 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (7) , 636
Three-Dimensional Melted Electrowriting Drug Coating Fibers for the Prevention of Device-Associated Infections: A Pilot Study
Medical device-related infections (DRIs), especially prevalent among critically ill patients, impose significant health and economic burdens and are mainly caused by bacteria. Severe infections often necessitate device removal when antibiotic therapy is inefficient, delaying recovery. To tackle this issue, PCL drug-eluting coated meshes were explored, and they were printed via melt electrowriting (MEW). These meshes were coated with gentamicin sulfate (GS) and tetracycline hydrochloride (TCH) and underwent FTIR analysis to confirm drug integration. Antimicrobial activity was assessed via agar diffusion assays and biofilm formation assays against bacterial strains: Pseudomonas aeruginosa ATCC 27853, Escherichia coli ATCC 25922, Staphylococcus aureus ATCC 43300, and Staphylococcus epidermidis ATCC 35984. FTIR analysis evidenced the presence of the drugs in the meshes. TCH displayed broad-spectrum antimicrobial activity against all strains, whereas GS was effective against all except S. aureus. These findings indicate the potential of cost-effective ultra-fine drug coating fibers for medical device applications, offering infection prevention during implantation. This preliminary study demonstrates the feasibility of producing drug-eluting fibers for DRI prevention through a non-toxic, fast, and cost-efficient technique, paving the way for enhanced patient care and reduced healthcare costs.
- 21 June 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (7) , 636
Open AccessThree-Dimensional Melted Electrowriting Drug Coating Fibers for the Prevention of Device-Associated Infections: A Pilot Study
Medical device-related infections (DRIs), especially prevalent among critically ill patients, impose significant health and economic burdens and are mainly caused by bacteria. Severe infections often necessitate device removal when antibiotic therapy is inefficient, delaying recovery. To tackle this issue, PCL drug-eluting coated meshes were explored, and they were printed via melt electrowriting (MEW). These meshes were coated with gentamicin sulfate (GS) and tetracycline hydrochloride (TCH) and underwent FTIR analysis to confirm drug integration. Antimicrobial activity was assessed via agar diffusion assays and biofilm formation assays against bacterial strains: Pseudomonas aeruginosa ATCC 27853, Escherichia coli ATCC 25922, Staphylococcus aureus ATCC 43300, and Staphylococcus epidermidis ATCC 35984. FTIR analysis evidenced the presence of the drugs in the meshes. TCH displayed broad-spectrum antimicrobial activity against all strains, whereas GS was effective against all except S. aureus. These findings indicate the potential of cost-effective ultra-fine drug coating fibers for medical device applications, offering infection prevention during implantation. This preliminary study demonstrates the feasibility of producing drug-eluting fibers for DRI prevention through a non-toxic, fast, and cost-efficient technique, paving the way for enhanced patient care and reduced healthcare costs.