NANihal Abdurahiman

Nihal Abdurahiman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nihal Abdurahiman has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of User Interfaces for Actuated Control of Endoscopes During Flexible Endoscopy

    by Sofia Basha, Mohammad Khorasani, Nihal Abdurahiman, Jhasketan Padhan, Victor Baez, Abdulla Al-Ansari, Panagiotis Tsiamyrtzis, Aaron T. Becker, Nikhil V. Navkar

    Objective: Flexible endoscopy is a valuable tool in diagnostic procedures, enabling examination of internal areas via natural orifices. An actuation system tends to improve the procedural outcomes by enabling controlled movements of the endoscope and offering a stable view of the operative field. A user interface is used to issue actuation commands to these systems. Thus, selection of an ideal user interface is vital to improve the ergonomics for the endoscopist and to ensure efficient endoscope navigation. The objective of this work is to perform an in-depth comparative analysis of various user interfaces to optimize endoscope maneuverability. Methods and procedures: A custom-built actuation system was used to maneuver a flexible endoscope. The actuation system enabled translational and rotational movement of the endoscope’s shaft as well as supported left/right and up/down steering of the endoscope’s distal end. Four user interfaces (head-motion based device, eye-gaze based device, a stylus, and a joystick) working under three interaction modes (continuous, discrete, threshold) along with a clutching mechanism were used to issue commands to the actuation system. A user study was conducted to assess the effectiveness of the user interfaces for two scenarios: Scenario-A, which involved maneuvering the endoscope’s distal end to focus on a localized operative field, and Scenario-B, which required targeting polyps during the withdrawal phase of a simulated colonoscopy. Results: In Scenario-A, the head motion-based device and stylus, when used in continuous interaction mode, resulted in the shorter task duration and fewer clutches. The joystick, operating under threshold interaction mode, also demonstrated a reduced task duration. Additionally, the joystick led to fewer instances of the endoscope’s focus shifting outside the localized operative field. In Scenario-B, eye gaze-based device under discrete interaction mode took the longest duration for task completion. The continuous mode of the stylus took the shortest duration to target polyps, once visualized in the operating field. However, it also required the highest number of clutches compared to other user interface and interaction modes. Conclusion: The joystick consistently outperformed other interfaces across all interaction modes. Performance among the other user interfaces varied based on the parameters of the scenarios. Head motion-based and eye-based user interfaces enabled hands-free manipulation of the endoscope. This study establishes a benchmark for enhancing both user interfaces and interaction modes in actuated flexible endoscopy.

  • Open Access

    A Real-Time Markerless Approach for 3D Pose Estimation of Laparoscopic Instruments in Surgical Training Simulators

    by Dehlela Shabir, Jhasketan Padhan, Nihal Abdurahiman, Julien Abinahed, Zhigang Deng, Nikhil V. Navkar

    Box trainers are widely used for laparoscopic skills training due to their ease of setup and realistic tool-tissue interaction. Automating skill assessment on these systems can enhance training by reducing analysis time and eliminating subjective evaluations. Achieving this requires accurate real-time estimation of the instrument tooltip’s three-dimensional (3D) pose. However, existing methods either depend on additional sensing hardware, which introduces ergonomic challenges, or lack real-time capabilities. A modular architecture has been developed for estimation of an instrument’s tooltip pose from video frames acquired during laparoscopic training. Our method incorporates a GPU-based algorithm that takes input from a customized deep learning model (YOLOv7), detects the edges of the surgical instrument, and computes tooltip’s 3D pose. Additionally, an automated 3D-pose dataset generation technique is introduced to generate datasets for training the model. Our method was evaluated using a vision-based tracking experiment, achieving 3D positional errors of 0.72 mm, 0.88 mm, and 3.81 mm over the X, Y, and Z-axes, and an orientation error of 5.65° with an end-to-end latency of 144 ms and sustained real-time throughput of 11.4 frames per second (fps). The proposed method enables accurate estimation of laparoscopic instrument tooltip poses without the need for additional hardware or markers. This work represents a significant step toward automated skill assessment in laparoscopic training using box trainers.


  • Open Access

    Evaluating Human-Robot Interfaces for Maneuvering Surgical Laparoscopes using Robotic Scope Assistant Systems

    by Sofia Basha, Malek Anbatawi, Nihal Abdurahiman, Jhasketan Padhan, Victor M. Baez, Abdulla Al-Ansari, Panagiotis Tsiamyrtzis, Aaron T. Becker, Nikhil V. Navkar

    Robotic scope assistant systems allow surgeons to adjust the operative field view during surgery by robotically maneuvering laparoscopes. A Human-Robot Interface (HRI) is used for issuing commands to these systems, with an interaction mode mapping these commands to laparoscope movements. Optimizing the HRI and interaction mode can streamline laparoscope positioning as well as reduce cognitive workload, helping the surgeon focus on the surgical procedure. Comparing and assessing various HRIs and interaction modes is essential for efficient laparoscope maneuvering. This study evaluates HRIs based on head-motion, eye-motion, hand-motion, and voice-input operating under three interaction modes (namely: discrete, continuous, and threshold). The participants performed a user study comparing different HRIs under two simulated surgical scenarios (one in a real environment and the other in a virtual environment). The results indicated that head and eye-based HRIs performed well in continuous interaction mode, while the voice-based interface suffered from a delay. Conversely, hand-based HRIs demonstrated superior performance in both scenarios across all evaluation parameters. The study provides a benchmark for the comparison of different HRIs and provides insights into the effectiveness, limitations, and potential advantages of different HRIs.


  • Open Access

    An Actuated Variable-View Rigid Scope System to Assist Visualization in Diagnostic Procedures

    by Sofia Basha, Mohammad Khorasani, Nihal Abdurahiman, Jhasketan Padhan, Victor Baez, Abdulla Al-Ansari, Panagiotis Tsiamyrtzis, Aaron T. Becker, Nikhil V. Navkar

    Objective: Variable-view rigid scopes offer advantages compared to traditional angled laparoscopes for examining a diagnostic site. However, altering the scope’s view requires a high level of dexterity and understanding of spatial orientation. This requires an intuitive mechanism to allow an operator to easily understand the anatomical surroundings and smoothly adjust the scope’s focus during diagnosis. To address this challenge, the objective of this work is to develop a mechanized arm that assists in visualization using variable-view rigid scopes during diagnostic procedures. Methods: A system with a mechanized arm to maneuver a variable-view rigid scope (EndoCAMeleon – Karl Storz) was developed. A user study was conducted to assess the ability of the proposed mechanized arm for diagnosis in a preclinical navigation task and a simulated cystoscopy procedure. Results: The mechanized arm performed significantly better than direct maneuvering of the rigid scope. In the preclinical navigation task, it reduced the percentage of time the scope’s focus shifted outside a predefined track. Similarly, for simulated cystoscopy procedure, it reduced the duration and the perceived workload. Conclusion: The proposed mechanized arm enhances the operator’s ability to accurately maneuver a variable-view rigid scope and reduces the effort in performing diagnostic procedures. Clinical and Translational Impact Statement: The preclinical research introduces a mechanized arm to intuitively maneuver a variable-view rigid scope during diagnostic procedures, while minimizing the mental and physical workload to the operator.