Yu Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yu Gao has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Baomiao Wang
School of Electrical and Control Engineering, Xi’an University of Science and Technology
1 shared publication- Baomiao Wang
School of Electrical and Control Engineering, Xi’an University of Science and Technology, Xi’an 710699, China
1 shared publication Fei Guo
School of Electrical and Control Engineering, Xi’an University of Science and Technology
1 shared publication- Fei Guo
School of Electrical and Control Engineering, Xi’an University of Science and Technology, Xi’an 710699, China
1 shared publication Haibo Tian
School of Mechanical Engineering, Xi’an University of Science and Technology
1 shared publication- Haibo Tian
School of Mechanical Engineering, Xi’an University of Science and Technology, Xi’an, CHINA
1 shared publication
Latest Publications
- Open Access
- 25 August 2024
- Published by Institute of Electronics, Information and Communications Engineers (IEICE) in IEICE Electronics Express
- Vol. 21 (16) , 20240357
Investigating the impact of humidity on potential-induced degradation (PID) in photovoltaic modules with ash accumulation
A laboratory test platform was established to explore the impact of humidity on potential-induced degradation (PID) under ash-covered photovoltaic modules. The mechanism behind changes in leakage current and output power was thoroughly investigated. The results indicate that the combination of dust accumulation on the module surface and humidity significantly elevates the leakage current. Specifically, the leakage current experiences an exponential increase when humidity exceeds 45% (CRH).By utilizing Peck's equation, the correlation coefficient λ between the power degradation of dust-covered and clean modules was derived. This coefficient can accurately forecast the power loss of dust-covered modules, offering valuable insights for the maintenance of PV power stations.
- 25 August 2024
- Published by Institute of Electronics, Information and Communications Engineers (IEICE) in IEICE Electronics Express
- Vol. 21 (16) , 20240357
Open AccessInvestigating the impact of humidity on potential-induced degradation (PID) in photovoltaic modules with ash accumulation
A laboratory test platform was established to explore the impact of humidity on potential-induced degradation (PID) under ash-covered photovoltaic modules. The mechanism behind changes in leakage current and output power was thoroughly investigated. The results indicate that the combination of dust accumulation on the module surface and humidity significantly elevates the leakage current. Specifically, the leakage current experiences an exponential increase when humidity exceeds 45% (CRH).By utilizing Peck's equation, the correlation coefficient λ between the power degradation of dust-covered and clean modules was derived. This coefficient can accurately forecast the power loss of dust-covered modules, offering valuable insights for the maintenance of PV power stations.
- Open Access
Effect of Accumulated Dust Conductivity on Leakage Current of Photovoltaic Modules
Photovoltaic (PV) modules are often situated in hot and windy environments, such as deserts, where dust accumulation poses a significant problem. The build-up of dust can result in an increase in PV module leakage current, making the modules more vulnerable to potential-induced degradation (PID), ultimately leading to a reduction in the efficiency of PV power generation. In this study, we investigate the impact of dust accumulation on the surface of PV modules on leakage current. A dust model is developed based on the Arrhenius relation, taking into account the impact of temperature and density on dust conductivity. The equation for leakage current due to dust accumulation is derived based on the clean module leakage current equation. We undertake a simulation of natural conditions in a laboratory setting to analyze the impact of dust on the leakage current of photovoltaic modules. The results show the following: At high temperatures, the leakage current will significantly increase due to the elevated conductivity of the dust. The conductivity increased by 27.1%, 48.9%, 64.3%, and 118% for the four groups of dusty PV modules, respectively. Leakage current prediction has a better accuracy when dust is equated to series conductance. Dust can reduce the activation energy of PV modules by up to 3.48%.
Open AccessEffect of Accumulated Dust Conductivity on Leakage Current of Photovoltaic Modules
Photovoltaic (PV) modules are often situated in hot and windy environments, such as deserts, where dust accumulation poses a significant problem. The build-up of dust can result in an increase in PV module leakage current, making the modules more vulnerable to potential-induced degradation (PID), ultimately leading to a reduction in the efficiency of PV power generation. In this study, we investigate the impact of dust accumulation on the surface of PV modules on leakage current. A dust model is developed based on the Arrhenius relation, taking into account the impact of temperature and density on dust conductivity. The equation for leakage current due to dust accumulation is derived based on the clean module leakage current equation. We undertake a simulation of natural conditions in a laboratory setting to analyze the impact of dust on the leakage current of photovoltaic modules. The results show the following: At high temperatures, the leakage current will significantly increase due to the elevated conductivity of the dust. The conductivity increased by 27.1%, 48.9%, 64.3%, and 118% for the four groups of dusty PV modules, respectively. Leakage current prediction has a better accuracy when dust is equated to series conductance. Dust can reduce the activation energy of PV modules by up to 3.48%.