Mustapha Chaar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mustapha Chaar has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Christof Devriendt
Vrije Universiteit Brussel (VUB)
2 shared publications- Christof Devriendt
Department of Applied Mechanics, OWI-LAB, Vrije Universiteit Brussel, Brussels, 1050, Belgium
2 shared publications Wout Weijtjens
Vrije Universiteit Brussel (VUB)
2 shared publications- Wout Weijtjens
Vrije Universiteit Brussel
2 shared publications Maximillian Weil
Vrije Universiteit Brussel (VUB)
1 shared publicationYacine Bel-Hadj
1 shared publication
Latest Publications
- Open Access
- 28 August 2026
- Published by Copernicus GmbH
- p. 1-17
Comment on wes-2026-133
Thrust loading on wind turbines causes quasi-static loading that ultimately introduces fatigue loading on the turbine. Monitoring these quasi-static loads is relevant for assessing the residual lifetime of the asset. However, installing strain gauges on all assets is practically and economically infeasible; only a subset of turbines, referred to as fleet leaders, are instrumented to this level. Interestingly, these quasi-static loads also result in a temporary inclination or tilt of the tower, which can be picked up by accelerometers or inclinometers installed on the tower or nacelle. This paper proposes using gravity-sensitive tri-axial MEMS accelerometers placed in the nacelle to estimate the inclination and load characteristics of a fleet of turbines. To do this accurately, the MEMS sensor needs to be calibrated to offset installation errors and compensate for the turbines’ permanent inclination. For this purpose, long-term data from the MEMS accelerometer are processed, and the constituting offsets are estimated. After calibration, the quasi-static angles induced by loading can be estimated from the accelerometer. The derived load characteristics can then be used to extrapolate bending moments from fully instrumented fleet-leader turbines to the remainder of the wind farm. The bending moment is then used to assess damage-equivalent moments, and it was found that the accelerometer produces damage estimates similar to those obtained from strain gauges. Thus, the approach enables scalable and cost-effective farmwide load monitoring.
- 28 August 2026
- Published by Copernicus GmbH
- p. 1-17
Open AccessComment on wes-2026-133
Thrust loading on wind turbines causes quasi-static loading that ultimately introduces fatigue loading on the turbine. Monitoring these quasi-static loads is relevant for assessing the residual lifetime of the asset. However, installing strain gauges on all assets is practically and economically infeasible; only a subset of turbines, referred to as fleet leaders, are instrumented to this level. Interestingly, these quasi-static loads also result in a temporary inclination or tilt of the tower, which can be picked up by accelerometers or inclinometers installed on the tower or nacelle. This paper proposes using gravity-sensitive tri-axial MEMS accelerometers placed in the nacelle to estimate the inclination and load characteristics of a fleet of turbines. To do this accurately, the MEMS sensor needs to be calibrated to offset installation errors and compensate for the turbines’ permanent inclination. For this purpose, long-term data from the MEMS accelerometer are processed, and the constituting offsets are estimated. After calibration, the quasi-static angles induced by loading can be estimated from the accelerometer. The derived load characteristics can then be used to extrapolate bending moments from fully instrumented fleet-leader turbines to the remainder of the wind farm. The bending moment is then used to assess damage-equivalent moments, and it was found that the accelerometer produces damage estimates similar to those obtained from strain gauges. Thus, the approach enables scalable and cost-effective farmwide load monitoring.
- Open Access
- 30 July 2026
- Published by Copernicus GmbH in EGUsphere
- p. 1-17
Low-Frequency Fatigue monitoring using nacelle-mounted accelerometers
Thrust loading on wind turbines causes quasi-static loading that ultimately introduces fatigue loading on the turbine. Monitoring these quasi-static loads is relevant for assessing the residual lifetime of the asset. However, installing strain gauges on all assets is practically and economically infeasible; only a subset of turbines, referred to as fleet leaders, are instrumented to this level. Interestingly, these quasi-static loads also result in a temporary inclination or tilt of the tower, which can be picked up by accelerometers or inclinometers installed on the tower or nacelle. This paper proposes using gravity-sensitive tri-axial MEMS accelerometers placed in the nacelle to estimate the inclination and load characteristics of a fleet of turbines. To do this accurately, the MEMS sensor needs to be calibrated to offset installation errors and compensate for the turbines’ permanent inclination. For this purpose, long-term data from the MEMS accelerometer are processed, and the constituting offsets are estimated. After calibration, the quasi-static angles induced by loading can be estimated from the accelerometer. The derived load characteristics can then be used to extrapolate bending moments from fully instrumented fleet-leader turbines to the remainder of the wind farm. The bending moment is then used to assess damage-equivalent moments, and it was found that the accelerometer produces damage estimates similar to those obtained from strain gauges. Thus, the approach enables scalable and cost-effective farmwide load monitoring.
- 30 July 2026
- Published by Copernicus GmbH in EGUsphere
- p. 1-17
Open AccessLow-Frequency Fatigue monitoring using nacelle-mounted accelerometers
Thrust loading on wind turbines causes quasi-static loading that ultimately introduces fatigue loading on the turbine. Monitoring these quasi-static loads is relevant for assessing the residual lifetime of the asset. However, installing strain gauges on all assets is practically and economically infeasible; only a subset of turbines, referred to as fleet leaders, are instrumented to this level. Interestingly, these quasi-static loads also result in a temporary inclination or tilt of the tower, which can be picked up by accelerometers or inclinometers installed on the tower or nacelle. This paper proposes using gravity-sensitive tri-axial MEMS accelerometers placed in the nacelle to estimate the inclination and load characteristics of a fleet of turbines. To do this accurately, the MEMS sensor needs to be calibrated to offset installation errors and compensate for the turbines’ permanent inclination. For this purpose, long-term data from the MEMS accelerometer are processed, and the constituting offsets are estimated. After calibration, the quasi-static angles induced by loading can be estimated from the accelerometer. The derived load characteristics can then be used to extrapolate bending moments from fully instrumented fleet-leader turbines to the remainder of the wind farm. The bending moment is then used to assess damage-equivalent moments, and it was found that the accelerometer produces damage estimates similar to those obtained from strain gauges. Thus, the approach enables scalable and cost-effective farmwide load monitoring.
- 22 June 2024
- Published by Springer Nature
- p. 659-669
Scaling Operational Modal Analysis Through Delayed DBSCAN Tracking: Lessons from Widespread Offshore Wind Turbine Monitoring
- 22 June 2024
- Published by Springer Nature
- p. 659-669
Scaling Operational Modal Analysis Through Delayed DBSCAN Tracking: Lessons from Widespread Offshore Wind Turbine Monitoring
- Open Access
- 12 September 2023
- Published by DEStech Publications
TOWER VIBRATION-BASED ICING DETECTION ON OPERATIONAL WIND TURBINES
Ice accretion on wind turbines poses a significant safety risk, especially in densely populated areas. Ice built up on the blades can be thrown towards people and infrastructure and cause potential damage and harm. This risk is known and, as such, several solutions exist in today’s market to detect ice accretion on the blades and timely shut down the system. The industry consensus is that icing detection systems installed directly on the blades offer more reliable detection. However, (post-) installation of hardware on the blades poses some practical limitations, impacting the overall cost and maintainability. To complement existing technology this study proposes monitoring the whirling modes, which are the natural frequencies associated with the wind turbine rotor, through a sensitive accelerometer mounted on the tower. The working principles rely on the concept that the increase of mass due to ice will lower the natural frequencies of the rotor. Observing this phenomenon from the tower implies a similar working principle as some blade mounted systems, while having a sensor installed on the tower simplifies installation and maintenance. Utilizing SHM data from tower, an ice indicator was made during standstill and operation which provided a proof of concept for this method.
- 12 September 2023
- Published by DEStech Publications
Open AccessTOWER VIBRATION-BASED ICING DETECTION ON OPERATIONAL WIND TURBINES
Ice accretion on wind turbines poses a significant safety risk, especially in densely populated areas. Ice built up on the blades can be thrown towards people and infrastructure and cause potential damage and harm. This risk is known and, as such, several solutions exist in today’s market to detect ice accretion on the blades and timely shut down the system. The industry consensus is that icing detection systems installed directly on the blades offer more reliable detection. However, (post-) installation of hardware on the blades poses some practical limitations, impacting the overall cost and maintainability. To complement existing technology this study proposes monitoring the whirling modes, which are the natural frequencies associated with the wind turbine rotor, through a sensitive accelerometer mounted on the tower. The working principles rely on the concept that the increase of mass due to ice will lower the natural frequencies of the rotor. Observing this phenomenon from the tower implies a similar working principle as some blade mounted systems, while having a sensor installed on the tower simplifies installation and maintenance. Utilizing SHM data from tower, an ice indicator was made during standstill and operation which provided a proof of concept for this method.