Liangyi Lyu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Liangyi Lyu has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Hanjie Chen
Department of Electronic Engineering, Chinese University of Hong Kong, Hong Kong
3 shared publications - Rosa H. M. Chan
Department of Electrical Engineering, City University of Hong Kong
3 shared publications - Yuan-Ting Zhang
Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong, SAR, China
3 shared publications - Bangul Khan
Department of Biomedical Engineering College of Biomedicine City University of Hong Kong Kowloon Tong Hong Kong
1 shared publication Bee Luan Khoo
1 shared publicationBilawal Khan
1 shared publication
Latest Publications
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (17) , 26115-26131
Physiological Stratified Models for Personalized Cuffless Blood Pressure Estimation Using Wearable Multimodal Sensors
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (17) , 26115-26131
Physiological Stratified Models for Personalized Cuffless Blood Pressure Estimation Using Wearable Multimodal Sensors
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 30 (1) , 676-687
PDSNet: Patient-Disease Dual Spatial Similarity Neural Networks for Predicting Heart Failure Risk Using Short Electronic Health Records
Heart failure (HF) is a complex and heterogeneous syndrome caused by diverse factors, such as atrial fibrillation, diabetes, and pulmonary hypertension. The intricate pathophysiology of HF, coupled with variability in patient demographics and presentations, poses significant challenges to the effectiveness of existing deep learning models in HF risk prediction. In this paper, we propose a novel deep neural network, PDSNet, which leverages a new dual patient-disease spatial similarity strategy to improve HF risk prediction using short electronic health records. First, we develop ontology graphs to capture hierarchical relationships between patients based on HF-related symptoms and causes; Then, a bipartite graph model is utilized to learn spatial similarities between patients with similar hospital visit histories; Finally, we design a transformer-based architecture to integrate both temporal and spatial dynamics for predicting future hospital visits associated with HF risk. We benchmarked the PDSNet on predicting HF risk for 7,346 patients from the MIMIC-III dataset. Compared to seven state-of-the-art deep learning methods, our PDSNet model achieved improvements of 2%-12% in the area under the curve (AUC) score and 3%-18% in the F1 score. These findings highlight the promising potential of our proposed PDSNet to provide accurate and robust HF risk predictions, paving the way for efficient clinical decision support and personalized HF management.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 30 (1) , 676-687
PDSNet: Patient-Disease Dual Spatial Similarity Neural Networks for Predicting Heart Failure Risk Using Short Electronic Health Records
Heart failure (HF) is a complex and heterogeneous syndrome caused by diverse factors, such as atrial fibrillation, diabetes, and pulmonary hypertension. The intricate pathophysiology of HF, coupled with variability in patient demographics and presentations, poses significant challenges to the effectiveness of existing deep learning models in HF risk prediction. In this paper, we propose a novel deep neural network, PDSNet, which leverages a new dual patient-disease spatial similarity strategy to improve HF risk prediction using short electronic health records. First, we develop ontology graphs to capture hierarchical relationships between patients based on HF-related symptoms and causes; Then, a bipartite graph model is utilized to learn spatial similarities between patients with similar hospital visit histories; Finally, we design a transformer-based architecture to integrate both temporal and spatial dynamics for predicting future hospital visits associated with HF risk. We benchmarked the PDSNet on predicting HF risk for 7,346 patients from the MIMIC-III dataset. Compared to seven state-of-the-art deep learning methods, our PDSNet model achieved improvements of 2%-12% in the area under the curve (AUC) score and 3%-18% in the F1 score. These findings highlight the promising potential of our proposed PDSNet to provide accurate and robust HF risk predictions, paving the way for efficient clinical decision support and personalized HF management.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 30 (1) , 303-314
Multi-Wavelength Photoplethysmographic Assessment of Fingertip Vasculature for Auto-Calibrated Cuffless Blood Pressure Monitoring
Long-term cuffless monitoring of blood pressure (BP) is of immense value in the diagnosis and prevention of cardiovascular diseases (CVD). While there are critical needs for wearable cuffless BP monitoring devices in personalized CVD care and hypertension management, current technologies face challenges in long-term accuracy which limits significantly its clinical applicability. To maintain the accuracy of cuffless blood pressure forecasting, frequent calibration is a vital necessity. However, conventional BP calibration approaches are inherently inconvenient and time-consuming. In this work, we address the challenge by developing a novel auto-calibration system enabling long-term BP estimation. The innovation of this approach combines depth-resolved vascular characteristics extracted from multi-wavelength photoplethysmographic (MWPPG) measurements at fingertip, with an adaptive cross-modal knowledge distillation algorithm for continuous refinement of blood pressure estimation. We have evaluated the system on the CAS-BP database of over a thousand subjects using various calibration strategies. The results have shown that frequent calibration can effectively enhance the accuracy of long-term blood pressure estimation. Compared to traditional manual calibration, the proposed auto-calibration method can perform frequent calibration of the model without requiring the true BP values. Furthermore, under the condition of daily auto-calibration, the system attains an optimal Mean Absolute Error (MAE) of 3.77 mmHg and 2.62 mmHg for systolic BP (SBP) and diastolic BP (DBP) respectively, significantly outperforming the performance achieved through traditional calibration methods. This work provides a novel conceptual framework to guide the calibration of cuffless wearable devices for BP monitoring.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 30 (1) , 303-314
Open AccessMulti-Wavelength Photoplethysmographic Assessment of Fingertip Vasculature for Auto-Calibrated Cuffless Blood Pressure Monitoring
Long-term cuffless monitoring of blood pressure (BP) is of immense value in the diagnosis and prevention of cardiovascular diseases (CVD). While there are critical needs for wearable cuffless BP monitoring devices in personalized CVD care and hypertension management, current technologies face challenges in long-term accuracy which limits significantly its clinical applicability. To maintain the accuracy of cuffless blood pressure forecasting, frequent calibration is a vital necessity. However, conventional BP calibration approaches are inherently inconvenient and time-consuming. In this work, we address the challenge by developing a novel auto-calibration system enabling long-term BP estimation. The innovation of this approach combines depth-resolved vascular characteristics extracted from multi-wavelength photoplethysmographic (MWPPG) measurements at fingertip, with an adaptive cross-modal knowledge distillation algorithm for continuous refinement of blood pressure estimation. We have evaluated the system on the CAS-BP database of over a thousand subjects using various calibration strategies. The results have shown that frequent calibration can effectively enhance the accuracy of long-term blood pressure estimation. Compared to traditional manual calibration, the proposed auto-calibration method can perform frequent calibration of the model without requiring the true BP values. Furthermore, under the condition of daily auto-calibration, the system attains an optimal Mean Absolute Error (MAE) of 3.77 mmHg and 2.62 mmHg for systolic BP (SBP) and diastolic BP (DBP) respectively, significantly outperforming the performance achieved through traditional calibration methods. This work provides a novel conceptual framework to guide the calibration of cuffless wearable devices for BP monitoring.