ВСВолодимир Солодущенко

Володимир Солодущенко

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Володимир Солодущенко has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Multiparametric ultrasound phenotyping of paediatric liver cirrhosis for future artificial intelligence models

    by Borys Andriiovych Tarasiuk, Volodymyr Vladyslavovych Solodushchenko, Maryna Vasylivna Globa, Iryna Mykolaivna Dykan, Vitalii Olehovych Babenko

    Background. Multiparametric ultrasonographic characterization of cirrhotic liver involvement may provide standardized information for development of interpretable clinical decision support systems. Purpose – to identify informative structural and haemodynamic characteristics and establish parameters for future artificial intelligence modelling. Materials and methods. This case-control investigation included 32 children aged 6–18 years with cirrhotic liver involvement and 30 controls. Aetiology was autoimmune hepatitis in 19 patients and Wilson disease in 13. B-mode ultrasonography, Doppler assessment and two-dimensional shear wave elastography were performed. Statistical estimates were calculated from aggregate measurements. Results. Left-lobe enlargement occurred in 65.6% of patients versus 10.0% of controls; segment I enlargement, in 43.8% versus 6.7%; surface irregularity, in 40.6% versus 0%; umbilicalvein recanalization, in 21.9% versus 0%; and splenomegaly, in 50.0% versus 3.3%. Triphasic hepatic venous waveforms were absent in all patients but present in 90.0% of controls. Absence of triphasicity showed 100.0% sensitivity (95% confidence interval 89.3–100.0%) and 90.0% specificity (74.4–96.5%). Portal venous velocity was lower and proper hepatic arterial resistive index was higher among patients in both age subgroups. All four comparisons: p < 0.001 (Welch test). Surface irregularity, monophasic venous waveforms and umbilical-vein recanalization each demonstrated 100.0% specificity. Conclusions. The identified characteristics describe structural and haemody-namic alterations in the investigated population and offer candidate parameters for interpretable modelling. Diagnostic estimates require independent confirmation; artificial intelligence-based fibrosis staging was not evaluated. The parameter set requires prospective multicentre evaluation against a reference standard.

  • Open Access

    INTERPRETABLE AI-DRIVEN ULTRASOUND ANALYSIS FOR THE SELECTION OF PEDIATRIC PATIENTS FOR LIVER ELASTOGRAPHY: A PILOT STUDY

    by Volodymyr V. Soloduschenko, Maryna B. Dyba, Vitalii O. Babenko, Maryna V. Globa, Borys A. Tarasiuk

    Introduction. Standard two-dimensional B-mode liver ultrasound is the most accessible modality for primary diagnosis; however, its conventional visual interpretation in pediatric chronic diffuse liver diseases is limited by subjectivity and low sensitivity to early-stage fibrosis. Shear wave elastography requires specialized equipment and is frequently unavailable in primary care settings. The development of interpretable artificial intelligence (AI) tools for objective computer-aided analysis of echograms enables automated patient triage and rational identification of priority cohorts for referral to liver elastography.Aim. To evaluate the diagnostic performance and clinical interpretability of a developed AI-based computer tool designed for the automated triage of children with chronic diffuse liver diseases prior to elastographic examination.Materials and methods: In a retrospective single-center study, the clinical echogram archive of 105 children aged 5–18 years was analyzed. The total dataset comprised 661 regions of interest (ROIs) extracted from 337 two-dimensional B-mode ultrasound images acquired via expert-class ultrasound systems. Two-dimensional shear wave elastography (2D-SWE) served as the reference standard (stratification into stages F0 vs. F1–F4 based on verified kPa thresholds). A logistic regression model was trained using local grayscale intensity profiles (32 bins) to construct spatial local-support maps and compute an integrated patient score. Validation was performed using a 5-fold cross-validation scheme configured to strictly prevent data leakage (patient-level splitting). Additionally, a selective classification analysis was conducted by introducing an indeterminate/uncertainty zone (rejection option) for equivocal cases.Results. In the binary task of differentiating normal tissue (F0) from fibrotic changes (F1–F4) at the patient level, the model achieved an area under the ROC curve (AUC) of 0.91 [95% confidence interval: 0.84–0.96], a balanced accuracy of 0.83 [0.76–0.90], a sensitivity of 0.80 [0.68–0.91], and a specificity of 0.86 [0.77–0.95] at a standard operating threshold of 0.50. Implementing a screening threshold of 0.32 increased the sensitivity for detecting fibrotic changes to 0.91. Exploratory selective classification analysis revealed that routing equivocal cases to the indeterminate category captured 15 out of 17 (88%) baseline model errors. After filtering out these indeterminate cases, the balanced accuracy on the retained subset of patients increased to 0.90, and specificity reached 1.00 with a sensitivity of 0.80.Conclusions. The developed intelligent method provides high triage accuracy for children requiring subsequent elastographic fibrosis stratification. Spatial local-support maps render the model's logic clinically interpretable for clinicians by providing a visual explanation of the calculated score. While the selective classification method effectively routes equivocal cases to an expert review zone, the low coverage (only 31.4% of patients remained outside the indeterminate zone) limits its utility as a standalone screening tool.


  • Open Access

    DIAGNOSTIC PERFORMANCE OF MULTIPARAMETRIC ULTRASOUND WITH ARTIFICIAL INTELLIGENCE TOOLS IN PEDIATRIC DIFFUSE LIVER DISEASES

    by Vitalii O. Babenko, Volodymyr V. Soloduschenko, Maryna B. Dyba, Maryna V. Globa, Borys A. Tarasiuk, Марина Б. Диба, Борис А. Тарасюк

    Introduction. Chronic diffuse liver diseases in children require safe noninvasive assessment and repeated monitoring of fibrosis. Liver biopsy remains the reference method for morphological verification; however, in pediatric practice its use is limited by invasiveness, risk of complications, and ethical considerations. Multiparametric ultrasound, including shear wave elastography and Doppler assessment of blood flow, is suitable for longitudinal follow-up, yet interpretation of ultrasound features remains operator-dependent. Automated image analysis using artificial intelligence algorithms may increase objectivity and reproducibility of fibrosis stratification and support clinical decision-making. Aim. To evaluate the diagnostic accuracy of multiparametric ultrasound, including two-dimensional shear wave elastography and machine learning algorithms, for staging liver fibrosis in children. Materials and methods: This retrospective single-center study included 185 children (140 with chronic diffuse liver diseases and 45 controls). All participants underwent two-dimensional shear wave elastography, hepatic vein Doppler assessment, and grayscale ultrasound image analysis using two machine learning approaches: Model A (random forest algorithm; binary classification) and Model B (hierarchical ensemble; multiclass classification). The reference approach was clinical verification and risk stratification based on elastography findings. Results. A strong positive association was observed between elastography measures and Model B predictions (Spearman rank correlation coefficient 0.77). Model A demonstrated 84% specificity in differentiating normal findings from pathological changes. Model B showed higher sensitivity (83%) but tended to overestimate fibrosis at the boundary between minimal and moderate stages. Doppler patterns, particularly a monophasic hepatic vein waveform, were significantly associated with higher fibrosis stages. Conclusions. Integrating machine learning algorithms into the ultrasound protocol increases diagnostic objectivity; however, hierarchical approaches require calibration to reduce false-positive results in the borderline zone of early fibrosis stages.


  • Open Access

    Artificial intelligence and radiological diagnostics in hepatology

    by M. M. Kolotilov, V. V. Solodushchenko, B. A. Tarasyuk, V. S. Berezenko

    Artificial intelligence and radiological diagnostics in hepatology

  • Open Access

    ІЄРАРХІЧНИЙ АЛГОРИТМ МУЛЬТИКЛАСИФІКАЦІЇ СТАДІЙ ФІБРОЗУ ПЕЧІНКИ З ІНТЕГРОВАНИМ АНАЛІЗОМ ОБЛАСТЕЙ ІНТЕРЕСУ

    by Віталій Бабенко, Євген Настенко, Володимир Солодущенко, Володимир Павлов, Ірина Дикан

    Ультразвукове дослідження є провідним методом у діагностиці таких патологій, як хронічний гепатит і цироз печінки. Однак ефективність даного інструменту значною мірою залежить від кваліфікації лікаря, а інтерпретація зображень є суб'єктивною. Точна оцінка ультразвукових зображень вимагає значного досвіду фахівця в цій галузі. Впровадження автоматизованих систем класифікації стадій фіброзу печінки може стати розв’язанням проблеми нестачі висококваліфікованих радіологів, особливо в регіонах з обмеженими ресурсами. Дослідження, метою якого є розробка подібної системи, базувалося на матеріалах державної установи «Інститут ядерної медицини та променевої діагностики Національної академії медичних наук України». У дослідженні використовувався набір даних з 1059 сегментованих вручну областей інтересу з 585 ультразвукових зображень 162 пацієнтів. Кожному пацієнту була проведена біопсія печінки з подальшим гістопатологічним аналізом за системою METAVIR. Для класифікації оцінок METAVIR використовувались ансамблеві методи машинного навчання, а саме: випадковий ліс, XGBoost, LightGBM і ВЛДОС. Ефективність цих методів на різних стадіях фіброзу печінки оцінювалась за допомогою таких показників, як точність, чутливість і специфічність. Найкращі результати показали LightGBM (82% точності на тестовому наборі в задачі “F0-1 проти F2-4”, 86% точності в задачі “F0-2 проти F3-4” і 96% точності в задачі “F0-3 проти F4”) і ВЛДОС (77% точності в задачі “F0 проти F1-4”). При використанні цих моделей в запропонованому ієрархічному алгоритмі мультикласифікації стадій фіброзу була досягнута точність 99% для всіх суб’єктів. Результати дослідження підтверджують ефективність запропонованого алгоритму для визначення конкретної стадії фіброзу печінки за системою METAVIR з використанням звичайних ультразвукових зображень у В-режимі. Це відкриває перспективу швидкої та точної діагностики без необхідності використання додаткового обладнання або тестових процедур, що робить цю технологію потенційно корисною для підтримки діагностичних можливостей радіологів у клінічних умовах