NENir Emuna

Nir Emuna

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nir Emuna has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers

    Multiphysics Simulations of a Bioprinted Pulsatile Fontan Conduit

    by Zinan Hu, Jessica E. Herrmann, Erica L. Schwarz, Fannie M. Gerosa, Nir Emuna, Jay D. Humphrey, Adam W. Feinberg, Tain-Yen Hsia, Mark A. Skylar-Scott, Alison L. Marsden

    For single ventricle congenital heart patients, Fontan surgery is the final stage in a series of palliative procedures, bypassing the heart to enable passive flow of de-oxygenated blood from the inferior vena cava (IVC) to the pulmonary arteries. This circulation leads to severely elevated central venous pressure, diminished cardiac output, and thus numerous sequelae and premature mortality. To address these issues, we propose a bioprinted pulsatile conduit to provide a secondary power source for the Fontan circulation. A multiphysics computational framework was developed to predict conduit performance and to guide design prior to printing. Physics components included electrophysiology, cardiomyocyte contractility, and fluid-structure interaction coupled to a closed-loop lumped parameter network representing Fontan physiology. A range of myocardial contractility was considered and simulated. The initial conduit design with adult ventricular cardiomyocyte contractility values coupled to a Purkinje network demonstrated potential to reduce liver (IVC) pressure from 16.4 to 9.3 mmHg and increase cardiac output by 29%. After systematically assessing the impacts of contraction duration, fiber direction, and valve placement on conduit performance, we identified a favorable design that successfully reduces liver pressure to 7.3 mmHg and increases cardiac output by 38%, almost normalizing adverse hemodynamics in the lower venous circulation. Valves at the input and output of the conduit are essential to achieve these satisfactory results; without valves, performance is compromised. However, a potential drawback of the design is the elevation of superior vena cava (SVC) pressure, which varies linearly with liver pressure reduction.


  • Open Access

    Cellular stiffness sensing through talin 1 in tissue mechanical homeostasis

    by Manasa Chanduri, Abhishek Kumar, Dar Weiss, Nir Emuna, Igor Barsukov, Miusi Shi, Keiichiro Tanaka, Xinzhe Wang, Amit Datye, Jean Kanyo, et al.

    Tissue mechanical properties are determined mainly by the extracellular matrix (ECM) and actively maintained by resident cells. Despite its broad importance to biology and medicine, tissue mechanical homeostasis remains poorly understood. To explore cell-mediated control of tissue stiffness, we developed mutations in the mechanosensitive protein talin 1 to alter cellular sensing of ECM. Mutation of a mechanosensitive site between talin 1 rod-domain helix bundles R1 and R2 increased cell spreading and tension exertion on compliant substrates. These mutations promote binding of the ARP2/3 complex subunit ARPC5L, which mediates the change in substrate stiffness sensing. Ascending aortas from mice bearing these mutations showed less fibrillar collagen, reduced axial stiffness, and lower rupture pressure. Together, these results demonstrate that cellular stiffness sensing contributes to ECM mechanics, directly supporting the mechanical homeostasis hypothesis and identifying a mechanosensitive interaction within talin that contributes to this mechanism.


  • Open Access

    Optimized Biomechanical Design of a Pulsatile Fontan Conduit for Congenital Heart Palliation

    by Nir Emuna, Alison L. Marsden, Jay D. Humphrey

    The evolution of palliative surgical procedures for children born with congenital heart defects has proven remarkably successful in extending life, but the resulting non-physiological circulation predisposes to myriad sequelae that compromise quality of life and overall life span. Among these procedures, standard-of-care Fontan completion surgery bypasses the nonfunctional ventricle and provides steady flow of deoxygenated blood to the lungs via a synthetic conduit that typically connects the inferior vena cava to a pulmonary artery. This altered circulation reduces cardiac output, elevates central venous pressures, and possibly contributes to adverse remodeling of the pulmonary vessels. There is, therefore, strong motivation to develop a next generation Fontan conduit capable of serving as a sub-pulmonic pulsatile pump, and there are now several reports of initial attempts. None of these studies have been driven by biomechanical considerations, however, and none have achieved the desired functionality. We thus present a novel analytical framework to improve design and guide fabrication by focusing on the microstructure and material properties of the contractile myofibers and associated passive matrix. Our optimized designs simultaneously ensure desired levels of stroke volume, ejection fraction, and pressure generation given constraints on Frank-Starling myofiber contraction and the limited space within the thoracic cavity of a three-to four-year-old child. This analysis also highlights the need to minimize any associated axial force or torque generation that a pulsatile conduit could transmit to the host vessels at the requisite anastomoses.

  • Instability of Incompatible Bilayered Soft Tissues and the Role of Interface Conditions

    by Nir Emuna, David Durban

    Mechanical stability analysis is instructive in explaining biological processes like morphogenesis, organogenesis, and pathogenesis of soft tissues. Consideration of the layered, residually stressed structure of tissues, requires accounting for the joint effects of interface conditions and layer incompatibility. This paper is concerned with the influence of imposed rate (incremental) interface conditions (RICs) on critical loads in soft tissues, within the context of linear bifurcation analysis. Aiming at simplicity, we analyze a model of bilayered isotropic hyperelastic (neo-Hookean) spherical shells with residual stresses generated by “shrink-fitting” two perfectly bonded layers with radial interfacial incompatibility. This setting allows a comparison between available, seemingly equivalent, interface conditions commonly used in the literature of layered media stability. We analytically determine the circumstances under which the interface conditions are equivalent or not, and numerically demonstrate significant differences between interface conditions with increasing level of layer incompatibility. Differences of more than tenfold in buckling and 30% in inflation instability critical loads are recorded using the different RICs. Contrasting instability characteristics are also revealed using the different RICs in the presence of incompatibility: inflation instability can occur before pressure maximum, and spontaneous instability may be excluded for thin shells. These findings are relevant to the growing body of stability studies of layered and residually stressed tissues. The impact of interface conditions on critical thresholds is significant in studies that use concepts of instability to draw conclusions about the normal development and the pathologies of tissues like arteries, esophagus, airways, and the brain.