Joanna Lemańska
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Joanna Lemańska has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Slawomir Jednorog
Central Laboratory for Radiological Protection , Konwaliowa 7 St. , Warsaw , Poland
2 shared publications Agnieszka Matysiak
Central Laboratory for Radiological Protection , Konwaliowa 7 St. , Warsaw , Poland
1 shared publicationBarbara Piotrowska
Central Laboratory for Radiological Protection , Konwaliowa 7 St. , Warsaw , Poland
1 shared publication- Bartłomiej Fliszkiewicz
Military University of Technology in Warsaw
1 shared publication - Karol Wiatr
Central Laboratory for Radiological Protection , Konwaliowa 7 St. , Warsaw , Poland
1 shared publication - Katarzyna Wołoszczuk
Central Laboratory for Radiological Protection, Konwaliowa 7, 03-194 Warsaw, Poland
1 shared publication
Latest Publications
- Open Access
- 14 January 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (2) , 823
Mitigating Indoor Radon Exposure: The Effect of Air Purifiers on Radon Progeny
Radon is one of the leading causes of lung cancer worldwide. Following the implementation of the European Council Directive 2013/59/EURATOM, regular measurements of radon concentrations in workplaces have been carried out in European countries for approximately ten years. This provides a basis for assessing the exposure of workers and the general population to radon, as well as for determining the need to implement measures aimed at reducing this exposure. In addition to commonly used methods that focus on eliminating radon sources or minimizing its ingress into buildings, there are also temporary measures available, such as using air purifiers to improve indoor air quality. Although they are not recommended as a standalone or definitive solution, they can be useful as an interim measure—until appropriate actions to reduce indoor radon concentrations are implemented. In this study, five commercially available air purifiers were tested under controlled laboratory conditions to assess their impact on radon and its decay products. The results show that none of the tested devices significantly reduced gaseous radon concentrations. However, the air purifiers were highly effective in removing radon progeny, achieving a 95–99% reduction in potential alpha energy concentration (PAEC) and reducing the equilibrium factor from 48 to 76% to 0–2%. From a sustainability perspective, these findings are relevant for public health protection, responsible consumer decision-making, and evidence-based indoor air quality management. By distinguishing between ineffective radon gas removal and effective reduction of dose-relevant decay products, this study supports sustainable risk mitigation strategies and helps prevent the misuse of energy- and resource-intensive technologies for purposes they cannot fulfill.
- 14 January 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (2) , 823
Open AccessMitigating Indoor Radon Exposure: The Effect of Air Purifiers on Radon Progeny
Radon is one of the leading causes of lung cancer worldwide. Following the implementation of the European Council Directive 2013/59/EURATOM, regular measurements of radon concentrations in workplaces have been carried out in European countries for approximately ten years. This provides a basis for assessing the exposure of workers and the general population to radon, as well as for determining the need to implement measures aimed at reducing this exposure. In addition to commonly used methods that focus on eliminating radon sources or minimizing its ingress into buildings, there are also temporary measures available, such as using air purifiers to improve indoor air quality. Although they are not recommended as a standalone or definitive solution, they can be useful as an interim measure—until appropriate actions to reduce indoor radon concentrations are implemented. In this study, five commercially available air purifiers were tested under controlled laboratory conditions to assess their impact on radon and its decay products. The results show that none of the tested devices significantly reduced gaseous radon concentrations. However, the air purifiers were highly effective in removing radon progeny, achieving a 95–99% reduction in potential alpha energy concentration (PAEC) and reducing the equilibrium factor from 48 to 76% to 0–2%. From a sustainability perspective, these findings are relevant for public health protection, responsible consumer decision-making, and evidence-based indoor air quality management. By distinguishing between ineffective radon gas removal and effective reduction of dose-relevant decay products, this study supports sustainable risk mitigation strategies and helps prevent the misuse of energy- and resource-intensive technologies for purposes they cannot fulfill.
- Open Access
- 1 June 2024
- Published by Walter de Gruyter GmbH in Nukleonika
- Vol. 69 (2) , 107-111
Radiation impact of ashes from the combustion of bottom sediments in a municipal sewage treatment plant, Czajka, located in Warsaw, Poland
The aim of the present research was to assess the radiological importance of the fly ashes generated from the incineration of sludge from the “Czajka” sewage treatment plant located in Warsaw, Poland. The γ-spectrometry technique was employed for their radiometry. The high purity germanium (HPGe) detector was mathematically energy-efficiency calibrated. The ash samples were measured two times, i.e., after 24 days and after 3 months of storage. Storage was supposed to provide a radioactive equilibrium. Radionuclides from three natural decay series, i.e., uranium–radium, uranium–actinium, and thorium, were detected in the ash samples. Apart from these, 40 K, 137 Cs, and 7 Be were also detected. The indicated levels of radionuclides do not produce radioactive hazards, regardless of the method used for further management.
- 1 June 2024
- Published by Walter de Gruyter GmbH in Nukleonika
- Vol. 69 (2) , 107-111
Open AccessRadiation impact of ashes from the combustion of bottom sediments in a municipal sewage treatment plant, Czajka, located in Warsaw, Poland
The aim of the present research was to assess the radiological importance of the fly ashes generated from the incineration of sludge from the “Czajka” sewage treatment plant located in Warsaw, Poland. The γ-spectrometry technique was employed for their radiometry. The high purity germanium (HPGe) detector was mathematically energy-efficiency calibrated. The ash samples were measured two times, i.e., after 24 days and after 3 months of storage. Storage was supposed to provide a radioactive equilibrium. Radionuclides from three natural decay series, i.e., uranium–radium, uranium–actinium, and thorium, were detected in the ash samples. Apart from these, 40 K, 137 Cs, and 7 Be were also detected. The indicated levels of radionuclides do not produce radioactive hazards, regardless of the method used for further management.
- Open Access
- 1 June 2024
- Published by Walter de Gruyter GmbH in Nukleonika
- Vol. 69 (2) , 87-91
The influence of method precision on assessing radiological hazards for patients using radium water in balneotherapy
The influence of uncertainty on the method adopted for the determination of radioactive radium concentration in water was analyzed due to the assessment of the radiation hazards of balneotherapy. For the calculation, we considered the influence of the bath in radioactive water containing only 226 Ra. 226 Ra concentration was determined with two γ-spectrometers armed with HPGe detectors with different relative efficiencies. Both spectrometers were energy-efficiency calibrated with a calibration source and based on numerical simulations. Different methods for qualitative γ-spectrum analysis were adopted. The emanation method and the liquid scintillation method were also used. The uncertainty of humans hazard assessment linearly depends on the adopted radiometric method precision. For effective dose calculation, two models were adopted: the model of external exposure proposed by ICRP Publication 144 and the Reference Men model proposed by ICRP Publication 23, respectively.
- 1 June 2024
- Published by Walter de Gruyter GmbH in Nukleonika
- Vol. 69 (2) , 87-91
Open AccessThe influence of method precision on assessing radiological hazards for patients using radium water in balneotherapy
The influence of uncertainty on the method adopted for the determination of radioactive radium concentration in water was analyzed due to the assessment of the radiation hazards of balneotherapy. For the calculation, we considered the influence of the bath in radioactive water containing only 226 Ra. 226 Ra concentration was determined with two γ-spectrometers armed with HPGe detectors with different relative efficiencies. Both spectrometers were energy-efficiency calibrated with a calibration source and based on numerical simulations. Different methods for qualitative γ-spectrum analysis were adopted. The emanation method and the liquid scintillation method were also used. The uncertainty of humans hazard assessment linearly depends on the adopted radiometric method precision. For effective dose calculation, two models were adopted: the model of external exposure proposed by ICRP Publication 144 and the Reference Men model proposed by ICRP Publication 23, respectively.