HSHaoxuan Si

Haoxuan Si

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Haoxuan Si has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • High-resolution Dante spectrometer based on quasi-monochromatic multilayer mirror array for soft X-ray spectral measurement in plasma diagnostics

    by Hao Xu, Ke Dong, Ermeng Zhang, Huiyao Du, Haoxuan Si, Jun Chen, Yongtang Liu, Zhe Zhang, Zhanshan Wang, Bo Tang, et al.

    Soft X-ray spectroscopic diagnostics based on Dante spectrometers are essential for evaluating plasma conditions driven by Z-pinch or laser fusion. A Dante spectrometer configuration capable of achieving low spectral measurement uncertainty remains a bottleneck problem at present. This paper develops a quantitative uncertainty-analysis framework for Dante spectrometers employing an array of quasi-monochromatic multilayer mirrors. Accordingly, we further developed a set of practical methods, including the precise synchrotron radiation calibration and optimized spectrometer installation, to effectively suppress these measurement uncertainties. For implementation, we developed a Dante spectrometer covering 100–1000 eV and validated it on a Z-pinch platform. The relative expanded uncertainty of individual channels was maintained within 2%–3%, and the reconstructed spectral-distribution uncertainty was better than 3.2%.


  • Multispectral Schwarzschild imaging system for the extreme ultraviolet emission measurement of tokamak plasma: erratum

    by Haoxuan Si, Shengzhen Yi, Tingfeng Ming, Zhe Zhang, Gongshun Li, Shanwei Hou, Li Jiang, Zhanshan Wang, Xiang Gao, XiaoJu Liu, et al.

    This erratum corrects the affiliation addresses of authors of our paper [ Opt. Express 32, 43748 (2024).10.1364/OE.545563 ].

  • Multispectral Schwarzschild imaging system for the extreme ultraviolet emission measurement of tokamak plasma

    by Haoxuan Si, Shengzhen Yi, Tingfeng Ming, Zhe Zhang, Gongshun Li, Shanwei Hou, Li Jiang, Zhanshan Wang, Xiang Gao, XiaoJu Liu, et al.

    A multispectral extreme ultraviolet imaging system based on a separated multichannel Schwarzschild objective was developed for emission measurements of tokamak plasma, with a wide field of view, high spatial resolution, and multispectral resolution. Multiple energy responses were realized by depositing different multilayer coatings on each mirror, targeting the interesting spectral lines of common impurities, such as Ne, C, and W, observed in tokamak experiments. Direct-current magnetron sputtering in conjunction with mask reshaping was employed to fabricate highly uniform multilayers on large-curvature substrates, achieving a thickness control accuracy of ±0.1 nm. Furthermore, this paper proposes an assembly and adjustment scheme that transitions from single-channel centering to multichannel integration, ensuring high-precision alignment across all channels. The design, preparation, and experimental validation of the proposed system are reported. The system was experimentally validated in the Experimental and Advanced Superconducting Tokamak facility, successfully detecting all target spectral lines. The results of the study demonstrate the feasibility of electron temperature measurements using the proposed system.


  • Open Access

    High-resolution, highly monochromatic, time-framed, x-ray-backlit-imaging diagnostics with dual-channel toroidal crystals

    by Huiyao Du, Haoxuan Si, Li Jiang, Shengzhen Yi, Zhanshan Wang, Jiaqin Dong

    Here, we developed a high-resolution, dual-channel toroidal-crystal x-ray imager for time-framed x-ray backlit imaging diagnostics using the 4.727 keV helium-like Ti line. We also presented a method for adjusting the dual-channel imager through the self-imaging of a two-dimensional periodic object. Offline x-ray experiments achieved a spatial resolution of ∼5.0 μm in the center and better than 8.0 μm within a field of view (FOV) of ∼2 mm. At the ShenGuang-III prototype laser facility, we obtained imaging results with a spatial resolution of better than 5 μm within an FOV of ±40 µm. This imager thus provides a way of observing with high spatial, temporal, and spectral resolutions to diagnose the behavior of laser-produced plasma.


  • Direct multiple monochromatic x-ray imaging with a pinhole array and a laterally graded multilayer mirror

    by Hao Xu, Shengyou Wen, Haoxuan Si, Qiushi Huang, Zhe Zhang, Feng Zhang, Shengzhen Yi, Zhanshan Wang

    Multiple monochromatic x-ray imaging (MMI) is a technique for diagnosing the emission spectra of tracer elements in laser-driven inertial confinement fusion experiments. This study proposes an MMI method that combines a simple pinhole array with a laterally graded multilayer mirror. The method directly obtains multiple monochromatic x-ray images by regulating the multilayer thickness in different mirror positions to compensate for the energy-broadening effect. This paper presents a comprehensive design scheme, the multilayer fabrication and experimental verification of the gradient MMI imaging performance. The experimental results show that the method achieves monochromatic imaging with a spectral resolution of ∼70–90 eV in several keV energy regions. This paper presents a practical diagnostic approach for directly and synchronously capturing the spatial, temporal, and spectral information of laser plasma x rays.