LLLixuan Li

Lixuan Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lixuan Li has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Age Differences in Flow Experience During Body Movement–Controlled Video Game Rehabilitation Tasks: Cross-Sectional Study

    by Shiyi Tong, Lixuan Li, Yuankun Zhang, Weiyan Ren, Fang Pu

    Background: Body movement–controlled video games (BMCVGs) are increasingly adopted in rehabilitation because they combine physical training with interactive engagement. Flow experience, a critical factor for enhancing user engagement and training efficacy, exhibits age-related differences that are essential for designing age-appropriate rehabilitation tasks. However, current BMCVG rehabilitation tasks often overlook these age-related differences in subjective experience, leading to insufficient engagement among older adults. Objective: This study aimed to explore differences in flow experience between younger and older adults when performing the same BMCVG rehabilitation task and to provide empirical evidence for designing personalized and age-appropriate programs. Methods: A total of 40 participants were recruited, including 21 older adults (mean age 63.00, SD 6.64 y; n=10, 48% male participants) and 19 younger adults (mean age 24.68, SD 1.16 y; n=9, 47% male participants). Participants performed the “Space Pop” task in Kinect Adventures , simulating limb coordination training. Flow experience was assessed using the Chinese version of the Flow State Scale-2, which measures 9 dimensions of flow. Group differences were analyzed using the nonparametric Wilcoxon rank-sum tests, and effect sizes (Cohen d ) were calculated via bootstrap estimation. Results: Older adults exhibited significantly lower overall flow experience than younger adults (W=339.5; P <.001; Cohen d =1.45; η 2 =0.37). Significant differences were also found in the dimensions of “challenge-skill balance” (W=339; P <.001); “clear goals” (W=271; P =.04); “sense of control” (W=389.5; P <.001); and “loss of self-consciousness” (W=268; P =.048). The largest effect was observed in the “sense of control” dimension (Cohen d =3.22; η 2 =0.74), indicating it was the most significantly impacted by age. Other dimensions (eg, concentration and time transformation) showed no significant differences. Conclusions: Age plays a significant role in shaping flow experiences during BMCVG rehabilitation tasks. Older adults’ reduced flow may be attributed to declines in cognitive processing speed, motor control, and self-efficacy, which particularly impair their sense of control and goal clarity. Tailoring designs through strategies such as dynamic difficulty adjustment, clearer goal cues, and reduced motor demands is crucial. These adaptations can enhance older adults’ sense of control and immersion, promoting active participation and ultimately improving rehabilitation outcomes.


  • Open Access

    Wearable Device–Based Respiratory Complexity Analysis for Detecting Pulmonary Congestion in Patients With Heart Failure: Observational Exploratory Study

    by Mengwei Li, Yu Kang, Shuanglin Zhao, Xiu Zhang, Zheng Liu, Lixuan Li, Qing Zhang, Zhengbo Zhang

    Background: Excessive pulmonary congestion (PC) is a major contributor to heart failure (HF) deterioration and often necessitates emergency hospitalization. Early detection of PC-related respiratory abnormalities via wearable devices could enable prompt intervention and reduce admissions. However, the feasibility of using wearables to detect specific respiratory biomarkers of PC remains unclear. Objective: This study aimed to evaluate the feasibility of using wearables to monitor respiratory data in hospitalized patients with HF and to determine if these signals could distinguish patients with HF and PC. Methods: This single-center, observational, exploratory study enrolled hospitalized patients with HF without severe lung diseases or need for intensive care or ventilation. All participants wore a designated device for ≥24 hours starting within 24 hours after admission; only nighttime data were analyzed. Breathing patterns were quantified across the respiratory cycle, amplitude, and multiscale entropy (MSE). Patients underwent comprehensive evaluations, including vital signs, laboratories, echocardiography, and a 28-zone lung ultrasound to define PC (>5 B-lines) within the first 24 hours. Results: The study enrolled 62 patients with HF between May 2021 and November 2022, including 44 with PC. Compared with patients with non-PC, those with PC demonstrated significantly prolonged mean expiratory time (TE; mean 2.17, SD 0.43 s vs mean 1.94, SD 0.34 s, P=.03), elevated expiratory time ratio (TE_ratio; mean 59.12%, SD 2.94% vs mean 56.4%, SD 3.36%, P=.006), and higher area under the curves (AUC) of MSE values for scales 1 to 5 (area_1_5) and scales 6 to 20 (area_6_20) in respiratory amplitude (RA; area_1_5 mean 4.20, SD 1.52 vs area_1_5 mean 2.93, SD 1.03, P<.001; and area_6_20 mean 8.86, SD 3.14 vs area_6_20 mean 12.28, SD 4.84, P=.002). Logistic regression identified mean TE_ratio, RA area_1_5, and RA area_6_20 as significant predictors of PC (P<.05). After adjusting for clinical confounders, both RA area_1_5 and RA area_6_20 remained independently associated with PC. Receiver operating characteristic analysis revealed that RA area_1_5 had the largest AUC of 0.75 (95% CI 0.63‐0.88, P=.002), with 65.9% sensitivity and 73.3% specificity. For the multivariate logistic regression model constructed using combined parameters of diastolic blood pressure, logarithmically transformed N-terminal pro-B-type natriuretic peptide, New York Heart Association class IV, mean TE_ratio, RA area_1_5, and RA area_6_20, the AUC was 0.91 (95% CI 0.84-0.98, P<.001), sensitivity of 77.3%, and specificity of 88.9%. Conclusions: In this exploratory study, wearable-based MSE analysis distinguished hospitalized patients with HF with and those without PC, showing prolonged expiratory phases and increased respiratory amplitude complexity in the PC group.

  • Open Access

    Age Differences in Flow Experience During Virtual Reality Rehabilitation Tasks: A Cross-Sectional Study (Preprint)

    by Shiyi Tong, Lixuan Li, Yuankun Zhang, Fang Pu, Weiyan Ren

    BACKGROUND Virtual reality (VR) is increasingly applied in rehabilitation training. Flow experience, a critical factor for enhancing user engagement and training efficacy, exhibits age-related differences that are essential for designing elderly-friendly rehabilitation tasks. However, current VR rehabilitation systems often overlook age-related subjective experience disparities, leading to insufficient engagement among older adults. OBJECTIVE This study aims to explore differences in flow experience between younger and older adults during identical VR rehabilitation tasks and provide empirical evidence for designing personalized elderly rehabilitation programs. METHODS We recruited 21 older adults (mean age: 63.00 ± 6.64 years, 10 males) and 19 younger adults (mean age: 24.68 ± 1.16 years, 9 males). Participants performed the "Space Pop" task in Kinect Adventures (simulating limb coordination training) using VR. Flow experience was measured using the Chinese version of the Flow State Scale-2 (CFSS-2). Group differences were analyzed via Wilcoxon rank-sum tests. RESULTS Older adults exhibited significantly lower overall flow experience than younger adults (p < 0.001, d = 1.45), with significant differences in the dimensions of "challenge-skill balance" (p < 0.001), "clear goals" (p = 0.044), "sense of control" (p < 0.001), and "loss of self-consciousness" (p = 0.048). Other dimensions (e.g., concentration, time transformation) showed no statistical differences. CONCLUSIONS Age significantly impacts flow experience in VR rehabilitation tasks. Tailoring designs through dynamic difficulty adjustment, intuitive goal cues, and reduced motor demands can enhance older adults’ control, immersion, and active participation, thereby improving health outcomes.

  • Open Access

    Benefits From Different Modes of Slow and Deep Breathing on Vagal Modulation

    by Deshan Ma, Conghui Li, Wenbin Shi, Yong Fan, Hong Liang, Lixuan Li, Zhengbo Zhang, Chien-Hung Yeh

    Objective: Slow and deep breathing (SDB) is a relaxation technique that can increase vagal activity. Respiratory sinus arrhythmia (RSA) serves as an index of vagal function usually quantified by the high-frequency power of heart rate variability (HRV). However, the low breathing rate during SDB results in deviations when estimating RSA by HRV. Besides, the impact of the inspiration-expiration (I: E) ratio and guidelines ways (fixed breathing rate or intelligent guidance) on SDB is not yet clear. Methods: In our study, 30 healthy people (mean age = 26.5 years, 17 females) participated in three SDB modes, including 6 breaths per minute (bpm) with an I:E ratio of 1:1/ 1:2, and intelligent guidance mode (I:E ratio of 1:2 with guiding to gradually lower breathing rate to 6 bpm). Parameters derived from HRV, multimodal coupling analysis (MMCA), Poincaré plot, and detrended fluctuation analysis were introduced to examine the effects of SDB exercises. Besides, multiple machine learning methods were applied to classify breathing patterns (spontaneous breathing vs. SDB) after feature selection by max-relevance and min-redundancy. Results: All vagal-activity markers, especially MMCA-derived RSA, statistically increased during SDB. Among all SDB modes, breathing at 6 bpm with a 1:1 I:E ratio activated the vagal function the most statistically, while the intelligent guidance mode had more indicators that still significantly increased after training, including SDRR and MMCA-derived RSA, etc. About the classification of breathing patterns, the Naive Bayes classifier has the highest accuracy (92.2%) with input features including LFn, CPercent, pNN50, α2, SDRatio, α1, and LF. Conclusions: Our study proposed a system that can be applied to medical devices for automatic SDB identification and real-time feedback on the training effect. We demonstrated that breathing at 6 bpm with an I:E ratio of 1:1 performed best during the training phase, while intelligent guidance mode had a more long-lasting effect.