Kan Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Kan Zhu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Baris Kasikci
University of Washington, Seattle, WA, USA
2 shared publications - Dedong Xie
University of Washington, Seattle, WA, USA
1 shared publication - Ion Stoica
University of California, Berkeley, Berkeley, USA
1 shared publication - Jiarong Xing
Rice University, Houston, Texas, USA
1 shared publication - Lianmin Zheng
University of California, Berkeley, Berkeley, CA, USA
1 shared publication - Shuo Yang
University of California, Berkeley, Berkeley, USA
1 shared publication
Latest Publications
- Open Access
- 22 March 2026
- Published by Association for Computing Machinery (ACM)
- p. 255-273
BlendServe: Optimizing Offline Inference with Resource-Aware Batching
- 22 March 2026
- Published by Association for Computing Machinery (ACM)
- p. 255-273
Open AccessBlendServe: Optimizing Offline Inference with Resource-Aware Batching
- Open Access
- 8 July 2024
- Published by Association for Computing Machinery (ACM)
- p. 47-54
Can Storage Devices be Power Adaptive?
Power is becoming a scarce resource for data centers, raising the need for power adaptive system design---the ability to dynamically change power consumption---to match available power. Storage makes up an increasing fraction of total data center power consumption. As such, it holds great potential to contribute to data center power adaptivity. To this end, we conduct a measurement study of power control mechanisms on a variety of modern data center storage devices. By changing device power states and shaping IO, we achieve a power dynamic range of up to 59.4% of the device's maximum operating power. We also study power control trade-offs, including throughput and latency. Based on our observations, we construct storage device power-throughput models and discuss the implications on power adaptive storage system design.
- 8 July 2024
- Published by Association for Computing Machinery (ACM)
- p. 47-54
Open AccessCan Storage Devices be Power Adaptive?
Power is becoming a scarce resource for data centers, raising the need for power adaptive system design---the ability to dynamically change power consumption---to match available power. Storage makes up an increasing fraction of total data center power consumption. As such, it holds great potential to contribute to data center power adaptivity. To this end, we conduct a measurement study of power control mechanisms on a variety of modern data center storage devices. By changing device power states and shaping IO, we achieve a power dynamic range of up to 59.4% of the device's maximum operating power. We also study power control trade-offs, including throughput and latency. Based on our observations, we construct storage device power-throughput models and discuss the implications on power adaptive storage system design.