Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ming-Che Lu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Designs of Bayesian EWMA Variability Control Charts in the Presence of Measurement Error

    by Ming-Che Lu, Su-Fen Yang

    Statistical process control may lead to false detection results in the presence of measurement error, so it is necessary to deal with the effect of measurement error. The Bayesian exponentially weighted moving average (EWMA) variability control chart, first proposed by Lin et al., is a distribution-free control chart, and it can effectively monitor process variance even if the process skewness varies with time. This paper investigates the influence of measurement error on the Bayesian EWMA variability control chart, and it proposes two designs for the Bayesian EWMA variability control chart in the presence of measurement error. One is to modify the control limits based on the biased error-prone monitoring statistics, called the error-embedded control chart. The other is to design the control limits based on the error-corrected monitoring statistics, called the error-corrected control chart. Simulation results prove that both of the proposed control charts are reliable and have good detection performance in the presence of measurement error. Moreover, the average run lengths of the proposed control charts are exactly the same, indicating that both of them are equivalent control charts. Comparison results show that the existing control chart in Lin et al. is not in-control robust and fails to detect a downward shift in process variance when measurement error is present. Thus, using the error-embedded control chart or the error-corrected control chart to monitor processes with measurement errors is reliable and effective. Moreover, the proposed control charts, where π11 = 1 and π10 = 0, can be applied to monitor processes without measurement errors since their detection performance is equal to that of the existing control chart in Lin et al. Finally, we demonstrate the application of the error-embedded control chart and the error-corrected control chart to analyze the data from the service time system of a bank branch and the data from a semiconductor manufacturing process, showing that the proposed control charts can indeed be applied to data with measurement errors.

  • Pollution concentration monitoring using a new Birnbaum–Saunders control chart

    by Ming‐Che Lu, Su‐Fen Yang

    Air pollution monitoring is an important issue in environmental science. The Birnbaum–Saunders (BS) distribution, originally applied to describe product failure time distribution to fatigue failures and general random wear failures, is also well to describe the pollutant concentration data due to accumulations of various pollutants in the air over time. Sulfur dioxide (SO2) is a critical factor in air pollution. Hence, it is important to monitor its concentration variation for air pollution prevention. Due to the complexity of its distribution form, there is no reliable and easy‐to‐use control chart for monitoring pollutant concentrations based on the BS distribution. We found that the SO2 concentration data follows the BS distribution. In this study, we propose a new median control chart based on the exact sampling distribution of the monitoring statistic to detect shifts in the median of BS distribution. Thus, given the false alarm rate, the control limits for such control charts can be obtained precisely satisfying a preset in‐control average run length using Monte Carlo simulations. The out‐of‐control average run lengths are calculated by simulation to evaluate the detection performance of the proposed chart when the median shifts occur. We further compare the detection performance of the proposed chart and those of the existing control charts based on asymptotic sampling distributions. In order to improve the detection ability of the proposed chart for small median shifts, an exponentially weighted moving average (EWMA) control chart is constructed. The results of numerical analyses demonstrated that the proposed EWMA chart performs much better than all existing control charts for monitoring the median of BS distribution. Finally, the proposed control charts are applied to monitor the median of SO2 concentrations for air pollution control, showing that both charts can effectively detect a shift in the median of SO2 concentrations. The proposed EWMA control chart even detects out a small shift in the median of SO2 concentrations. The results provide a continuous monitoring solution for air pollution prevention.


  • A new phase II EWMA dispersion control chart

    by Su‐Fen Yang, Barry C. Arnold, Yen‐Ling Liu, Ming‐Che Lu, Shin‐Li Lu

    Statistical process control (SPC) methods are useful for improving or maintaining a manufacturing or service process in a stable and satisfactory state. Nowadays, in many industrial applications, it is necessary to simultaneously monitor more than two related quality variables of a process. Multivariate control charts are thus becoming an important research area. Using separate control charts to monitor related quality variables independently is very unreasonable and misleading. The problem of monitoring multivariate statistical process (MSPC) for several related quality variables is of current interest. So far in the literature, a few papers have discussed monitoring process dispersion for cases in which the process has a multivariate normal or non‐normal distribution. A new EWMA dispersion control chart is proposed to monitor the process covariance matrix. Moreover, the proposed new EWMA dispersion control chart is independent of the out‐of‐control process mean vector. It overcomes the problem in many existing covariance matrix control charts of assuming that there are no shifts in the process mean vector which, depending on the existence of shifts in mean, can lead to an increased false alarm rate. The derivation of the new EWMA dispersion control chart is illustrated and its out‐of‐control detection performance investigated. The proposed new EWMA dispersion control chart performs better than the existing control charts for detecting out‐of‐control process variances whether the covariances change or not. An example involving semi‐conductor data is adopted to demonstrate the application of the proposed new EWMA dispersion control chart.


  • Exact statistical inferences for the median of the Birnbaum–Saunders distribution

    by Ming-Che Lu, Dong-Shang Chang, Su-Fen Yang

    The two-parameter Birnbaum–Saunders distribution was derived to describe the failure time from a process of fatigue crack growth. The scale parameter is also the median of the distribution. The inferences for the median of the distribution are mostly based on the maximum likelihood methods and subject to large-sample requirements. In this paper, we develop the exact small-sample confidence intervals of the median of the distribution when the shape parameter is known and unknown, respectively. Moreover, an alternative consistent estimator with an explicit form for the median of the distribution is provided in this study. Finally, we develop the hypothesis testing for the median of the distribution based on a small sample. The Monte Carlo simulations are further carried out to prove the power of the proposed test well performance.


  • Open Access

    A Bayesian Control Chart for Monitoring Process Variance

    by Chien-Hua Lin, Ming-Che Lu, Su-Fen Yang, Ming-Yung Lee

    Automation in the service industry is emerging as a new wave of industrial revolution. Standardization and consistency of service quality is an important part of the automation process. The quality control methods widely used in the manufacturing industry can provide service quality measurement and service process monitoring. In particular, the control chart as an online monitoring technique can be used to quickly detect whether a service process is out of control. However, the control of the service process is more difficult than that of the manufacturing process because the variability of the service process comes from widespread and complex factors. First of all, the distribution of the service process is usually non-normal or unknown. Moreover, the skewness of the process distribution can be time-varying, even if the process is in control. In this study, a Bayesian procedure is applied to construct a Phase II exponential weighted moving average (EWMA) control chart for monitoring the variance of a distribution-free process. We explore the sampling properties of the new monitoring statistic, which is suitable for monitoring the time-varying process distribution. The average run lengths (ARLs) of the proposed Bayesian EWMA variance chart are calculated, and they show that the chart performs well. The simulation studies for a normal process, exponential process, and the mixed process of normal and exponential distribution prove that our chart can quickly detect any shift of a process variance. Finally, a numerical example of bank service time is used to illustrate the application of the proposed Bayesian EWMA variance chart and confirm the performance of the process control.