Daniel Krauss
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Daniel Krauss has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Bjoern Michael Eskofier
Friedrich-Alexander-Universität Erlangen-Nürnberg
6 shared publications - Lukas Engel
Friedrich-Alexander-Universität Erlangen-Nürnberg
4 shared publications - Martin Vossiek
Institute of Microwaves and Photonics, Friedrich-Alexander-Universitt Erlangen-Nrnberg, Erlangen, Germany
4 shared publications - Robert Richer
Machine Learning and Data Analytics Lab, Department Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Germany
4 shared publications - Alexander Koelpin
Hamburg University of Technology
3 shared publications - Ingrid Ullmann
Friedrich-Alexander-Universität Erlangen-Nürnberg
3 shared publications
Latest Publications
- Open Access
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 7, 54-62
Contactless Sleep Staging With Radar: A Transfer Learning Approach
Accurate sleep monitoring is essential to assess sleep quality and diagnose sleep disorders. Although sleep laboratories provide precise assessments, they are expensive, labor-intensive, and unsuitable for long-term or large-scale monitoring. Radar-based sensing offers a fully contactless alternative, enabling unobtrusive real-world sleep monitoring. However, the lack of large, labeled datasets has limited the development of robust sleep stage classification models. We address this with transfer learning to improve classification accuracy and generalization to unseen participants within the radar cohort. An LSTM model was pretrained on movement, HRV, and respiratory features from the MESA Sleep dataset ($>$1,100 participants) and fine-tuned using radar data from 44 synchronized polysomnography recordings. Transfer learning increased the Matthews Correlation Coefficient from 0.25 to 0.47 (five-class staging), particularly for Wake, N3, and REM sleep. Future work should explore domain-adaptation across modalities and cohorts. Our results highlight the potential of radar-based sleep analysis for scalable, contactless long-term sleep monitoring.
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 7, 54-62
Open AccessContactless Sleep Staging With Radar: A Transfer Learning Approach
Accurate sleep monitoring is essential to assess sleep quality and diagnose sleep disorders. Although sleep laboratories provide precise assessments, they are expensive, labor-intensive, and unsuitable for long-term or large-scale monitoring. Radar-based sensing offers a fully contactless alternative, enabling unobtrusive real-world sleep monitoring. However, the lack of large, labeled datasets has limited the development of robust sleep stage classification models. We address this with transfer learning to improve classification accuracy and generalization to unseen participants within the radar cohort. An LSTM model was pretrained on movement, HRV, and respiratory features from the MESA Sleep dataset ($>$1,100 participants) and fine-tuned using radar data from 44 synchronized polysomnography recordings. Transfer learning increased the Matthews Correlation Coefficient from 0.25 to 0.47 (five-class staging), particularly for Wake, N3, and REM sleep. Future work should explore domain-adaptation across modalities and cohorts. Our results highlight the potential of radar-based sleep analysis for scalable, contactless long-term sleep monitoring.
- Open Access
RadProPoser: A Framework for Human Pose Estimation with Uncertainty Quantification from Raw Radar Data
Radar-based human pose estimation (HPE) provides a privacy-preserving, illumination-invariant sensing modality but is challenged by noisy, multipath-affected measurements. We introduce RadProPoser, a probabilistic encoder-decoder architecture that processes complex-valued radar tensors from a compact 3-transmitter, 4-receiver MIMO radar. By incorporating variational inference into keypoint regression, RadProPoser jointly predicts 26 three-dimensional joint locations alongside heteroscedastic aleatoric uncertainties and can be recalibrated to predict total uncertainty. We explore different probabilistic formulations using both Gaussian and Laplace distributions for latent priors and likelihoods. On our newly released dataset with optical motion-capture ground truth, RadProPoser achieves an overall mean per-joint position error (MPJPE) of 6.425 cm, with 5.678 cm at the 45 degree aspect angle. The learned uncertainties exhibit strong alignment with actual pose errors and can be calibrated to produce reliable prediction intervals, with our best configuration achieving an expected calibration error of 0.021. As an additional demonstration, sampling from these latent distributions enables effective data augmentation for downstream activity classification, resulting in an F1 score of 0.870. To our knowledge, this is the first end-to-end radar tensor-based HPE system to explicitly model and quantify per-joint uncertainty from raw radar tensor data, establishing a foundation for explainable and reliable human motion analysis in radar applications.
Open AccessRadProPoser: A Framework for Human Pose Estimation with Uncertainty Quantification from Raw Radar Data
Radar-based human pose estimation (HPE) provides a privacy-preserving, illumination-invariant sensing modality but is challenged by noisy, multipath-affected measurements. We introduce RadProPoser, a probabilistic encoder-decoder architecture that processes complex-valued radar tensors from a compact 3-transmitter, 4-receiver MIMO radar. By incorporating variational inference into keypoint regression, RadProPoser jointly predicts 26 three-dimensional joint locations alongside heteroscedastic aleatoric uncertainties and can be recalibrated to predict total uncertainty. We explore different probabilistic formulations using both Gaussian and Laplace distributions for latent priors and likelihoods. On our newly released dataset with optical motion-capture ground truth, RadProPoser achieves an overall mean per-joint position error (MPJPE) of 6.425 cm, with 5.678 cm at the 45 degree aspect angle. The learned uncertainties exhibit strong alignment with actual pose errors and can be calibrated to produce reliable prediction intervals, with our best configuration achieving an expected calibration error of 0.021. As an additional demonstration, sampling from these latent distributions enables effective data augmentation for downstream activity classification, resulting in an F1 score of 0.870. To our knowledge, this is the first end-to-end radar tensor-based HPE system to explicitly model and quantify per-joint uncertainty from raw radar tensor data, establishing a foundation for explainable and reliable human motion analysis in radar applications.
- Open Access
- 22 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Contactless Sleep Staging with Radar: A Transfer Learning Approach
Accurate sleep monitoring is essential for assessing sleep quality and diagnosing sleep disorders. While sleep laboratories provide precise assessments, they are expensive, laborintensive, and unsuitable for long-term or large-scale monitoring. Radar-based sensing offers a fully contactless alternative, enabling unobtrusive real-world sleep monitoring. However, the lack of large, labeled datasets has limited the development of robust classification models. We propose a transfer learning approach to improve radar-based sleep staging. An LSTM model was pretrained on movement, HRV, and respiratory features from the MESA Sleep dataset (>1,100 participants), and finetuned using radar data from 44 synchronized polysomnography recordings. The transfer learning approach outperformed the radar-only baseline, increasing the Matthews Correlation Coefficient from 0.25 to 0.47 in five-class sleep staging, particularly for Wake, N3, and REM sleep. Future work should explore domain adaptation to enhance generalizability across modalities. Our results highlight the potential of radar-based sleep analysis for scalable, contactless long-term sleep monitoring.
- 22 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessContactless Sleep Staging with Radar: A Transfer Learning Approach
Accurate sleep monitoring is essential for assessing sleep quality and diagnosing sleep disorders. While sleep laboratories provide precise assessments, they are expensive, laborintensive, and unsuitable for long-term or large-scale monitoring. Radar-based sensing offers a fully contactless alternative, enabling unobtrusive real-world sleep monitoring. However, the lack of large, labeled datasets has limited the development of robust classification models. We propose a transfer learning approach to improve radar-based sleep staging. An LSTM model was pretrained on movement, HRV, and respiratory features from the MESA Sleep dataset (>1,100 participants), and finetuned using radar data from 44 synchronized polysomnography recordings. The transfer learning approach outperformed the radar-only baseline, increasing the Matthews Correlation Coefficient from 0.25 to 0.47 in five-class sleep staging, particularly for Wake, N3, and REM sleep. Future work should explore domain adaptation to enhance generalizability across modalities. Our results highlight the potential of radar-based sleep analysis for scalable, contactless long-term sleep monitoring.
- Open Access
- 11 April 2025
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 48 (9)
Incorporating respiratory signals for machine learning-based multimodal sleep stage classification: a large-scale benchmark study with actigraphy and heart rate variability
Insufficient sleep quality is directly linked to various diseases, making reliable sleep monitoring crucial for prevention, diagnosis, and treatment. As sleep laboratories are cost- and resource-prohibitive, wearable sensors offer a promising alternative for long-term unobtrusive sleep monitoring at home. Current unobtrusive sleep detection systems are mostly based on actigraphy (ACT) that tend to overestimate sleep due to a lack of movement in short periods of wakefulness. Previous research established sleep stage classification by combining ACT with cardiac information but has not investigated the incorporation of respiration in large-scale studies. For that reason, this work aims to systematically compare ACT-based sleep-stage classification with multimodal approaches combining ACT, heart rate variability (HRV) as well as respiration rate variability (RRV) using state-of-the-art machine- and deep learning algorithms. The evaluation is performed on a publicly available sleep dataset including more than 1000 recordings. Respiratory information is introduced through ECG-derived respiration features, which are evaluated against traditional respiration belt data. Results show that including RRV features improves the Matthews Correlation Coefficient (MCC), with long short-term memory (LSTM) algorithms performing best. For sleep staging based on AASM standards, the LSTM achieved a median MCC of 0.51 (0.16 IQR). Respiratory information enhanced classification performance, particularly in detecting wake and rapid eye movement (REM) sleep epochs. Our findings underscore the potential of including respiratory information in sleep analysis to improve sleep detection algorithms and, thus, help to transfer sleep laboratories into a home monitoring environment. The code used in this work can be found online at https://github.com/mad-lab-fau/sleep_analysis.
- 11 April 2025
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 48 (9)
Open AccessIncorporating respiratory signals for machine learning-based multimodal sleep stage classification: a large-scale benchmark study with actigraphy and heart rate variability
Insufficient sleep quality is directly linked to various diseases, making reliable sleep monitoring crucial for prevention, diagnosis, and treatment. As sleep laboratories are cost- and resource-prohibitive, wearable sensors offer a promising alternative for long-term unobtrusive sleep monitoring at home. Current unobtrusive sleep detection systems are mostly based on actigraphy (ACT) that tend to overestimate sleep due to a lack of movement in short periods of wakefulness. Previous research established sleep stage classification by combining ACT with cardiac information but has not investigated the incorporation of respiration in large-scale studies. For that reason, this work aims to systematically compare ACT-based sleep-stage classification with multimodal approaches combining ACT, heart rate variability (HRV) as well as respiration rate variability (RRV) using state-of-the-art machine- and deep learning algorithms. The evaluation is performed on a publicly available sleep dataset including more than 1000 recordings. Respiratory information is introduced through ECG-derived respiration features, which are evaluated against traditional respiration belt data. Results show that including RRV features improves the Matthews Correlation Coefficient (MCC), with long short-term memory (LSTM) algorithms performing best. For sleep staging based on AASM standards, the LSTM achieved a median MCC of 0.51 (0.16 IQR). Respiratory information enhanced classification performance, particularly in detecting wake and rapid eye movement (REM) sleep epochs. Our findings underscore the potential of including respiratory information in sleep analysis to improve sleep detection algorithms and, thus, help to transfer sleep laboratories into a home monitoring environment. The code used in this work can be found online at https://github.com/mad-lab-fau/sleep_analysis.
- Open Access
- 26 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Microwaves
- Vol. 5 (2) , 373-387
Advanced Millimeter Wave Radar-Based Human Pose Estimation Enabled by a Deep Learning Neural Network Trained With Optical Motion Capture Ground Truth Data
This paper presents a deep learning-enabled method for human pose estimation using radar target lists, obtained through a low-cost radar system with three transmitters and four receivers in a multiple-input multiple-output setup. We address challenges in previous research that often relied on extracting ground truth poses from RGB data, which are constrained by the need for 3D mapping and vulnerability to occlusions. To overcome these limitations, we utilized optical motion capture, which is widely recognized as the gold standard for precise human motion analysis. We conducted an extensive optical motion capture study involving various recorded movement activities, which resulted in mmRadPose, a new dataset that enhances existing benchmarks for radar-based pose estimation. This dataset has been made publicly accessible. Building on this approach, we designed an application-tailored radar signal processing chain to generate suitable input for the machine learning algorithm. We further developed an attentional recurrent-based deep learning model, PntPoseAT, which predicts 24 keypoints of human poses using radar target lists. We employed cross validation to thoroughly evaluate the model. This model surpasses previous approaches and achieves an average mean per-joint position error of $6.49 \,\mathrm{c}\mathrm{m}$ with a standard deviation of $3.74 \,\mathrm{c}\mathrm{m}$ on totally unseen test data. This excellent accuracy of the reconstructed keypoint positions is particularly remarkable when you consider that a very simple radar was used for the measurements. Additionally, we conducted a comprehensive analysis of the model's performance by exploring aspects such as network architecture, the use of long short-term memory versus gated recurrent units, input data selection, and the integration of multi-head self-attention mechanisms.
- 26 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Microwaves
- Vol. 5 (2) , 373-387
Open AccessAdvanced Millimeter Wave Radar-Based Human Pose Estimation Enabled by a Deep Learning Neural Network Trained With Optical Motion Capture Ground Truth Data
This paper presents a deep learning-enabled method for human pose estimation using radar target lists, obtained through a low-cost radar system with three transmitters and four receivers in a multiple-input multiple-output setup. We address challenges in previous research that often relied on extracting ground truth poses from RGB data, which are constrained by the need for 3D mapping and vulnerability to occlusions. To overcome these limitations, we utilized optical motion capture, which is widely recognized as the gold standard for precise human motion analysis. We conducted an extensive optical motion capture study involving various recorded movement activities, which resulted in mmRadPose, a new dataset that enhances existing benchmarks for radar-based pose estimation. This dataset has been made publicly accessible. Building on this approach, we designed an application-tailored radar signal processing chain to generate suitable input for the machine learning algorithm. We further developed an attentional recurrent-based deep learning model, PntPoseAT, which predicts 24 keypoints of human poses using radar target lists. We employed cross validation to thoroughly evaluate the model. This model surpasses previous approaches and achieves an average mean per-joint position error of $6.49 \,\mathrm{c}\mathrm{m}$ with a standard deviation of $3.74 \,\mathrm{c}\mathrm{m}$ on totally unseen test data. This excellent accuracy of the reconstructed keypoint positions is particularly remarkable when you consider that a very simple radar was used for the measurements. Additionally, we conducted a comprehensive analysis of the model's performance by exploring aspects such as network architecture, the use of long short-term memory versus gated recurrent units, input data selection, and the integration of multi-head self-attention mechanisms.
- 8 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radar Systems
- Vol. 2, 1174-1185
Radar-Based Tremor Quantification Using Deep Learning for Improved Parkinson’s and Palliative Care Assessment
Tremor is one of the most prevalent movement disorders, which is especially observed in patients with Parkinson’s disease and other conditions common in palliative care. Effective treatment and monitoring of disease progression are crucial in the context of palliative care for patients suffering from movement disorders. To this aim, the accurate and continuous detection and assessment of tremor characteristics, such as the tremor frequency, is required. Current evaluations by clinicians conducted during sporadic consultations are subjective and intermittent. Radar sensors provide continuous, objective evaluations of tremor motion in patient monitoring, offering a contactless, light-independent, and privacy-preserving method that directly measures tremor’s radial motion through the Doppler effect. As previous radar-based research lacks continuous tremor monitoring in realistic scenarios, this study uses a frequency-modulated continuous-wave radar to detect subtle tremor motions and estimates their frequencies amid challenges such as large body motion interference in a clinical setting. Seventeen healthy participants were instructed to mimic tremors in their right hand while performing three diagnostics movements frequently used in tremor assessment, and two activities that were inspired by common daily tasks encountered in palliative care settings. Tremor detection and frequency estimation was enabled by using suitable radar signal preprocessing followed by a neural network comprising convolutional and recurrent layers. Reference frequencies were obtained from an inertial measurement unit attached to the participants’ right hands. Cross-validation revealed a mean absolute error of 1.47 Hz in radar-based frequency estimation compared to the reference and a 90% accuracy in distinguishing the presence or absence of tremor, highlighting the proposed approach’s high potential for future tremor assessment.
- 8 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radar Systems
- Vol. 2, 1174-1185
Radar-Based Tremor Quantification Using Deep Learning for Improved Parkinson’s and Palliative Care Assessment
Tremor is one of the most prevalent movement disorders, which is especially observed in patients with Parkinson’s disease and other conditions common in palliative care. Effective treatment and monitoring of disease progression are crucial in the context of palliative care for patients suffering from movement disorders. To this aim, the accurate and continuous detection and assessment of tremor characteristics, such as the tremor frequency, is required. Current evaluations by clinicians conducted during sporadic consultations are subjective and intermittent. Radar sensors provide continuous, objective evaluations of tremor motion in patient monitoring, offering a contactless, light-independent, and privacy-preserving method that directly measures tremor’s radial motion through the Doppler effect. As previous radar-based research lacks continuous tremor monitoring in realistic scenarios, this study uses a frequency-modulated continuous-wave radar to detect subtle tremor motions and estimates their frequencies amid challenges such as large body motion interference in a clinical setting. Seventeen healthy participants were instructed to mimic tremors in their right hand while performing three diagnostics movements frequently used in tremor assessment, and two activities that were inspired by common daily tasks encountered in palliative care settings. Tremor detection and frequency estimation was enabled by using suitable radar signal preprocessing followed by a neural network comprising convolutional and recurrent layers. Reference frequencies were obtained from an inertial measurement unit attached to the participants’ right hands. Cross-validation revealed a mean absolute error of 1.47 Hz in radar-based frequency estimation compared to the reference and a 90% accuracy in distinguishing the presence or absence of tremor, highlighting the proposed approach’s high potential for future tremor assessment.
- Open Access
- 28 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 5, 725-734
EmRad: Ubiquitous Vital Sign Sensing Using Compact Continuous-Wave Radars
In biomedical monitoring, non-intrusive and continuous tracking of vital signs is a crucial yet challenging objective. Although accurate, traditional methods, such as electrocardiography (ECG) and photoplethysmography (PPG), necessitate direct contact with the patient, posing limitations for long-term and unobtrusive monitoring. To address this challenge, we introduce the EmRad system, an innovative solution harnessing the capabilities of continuous-wave (CW) radar technology for the contactless detection of vital signs, including heart rate and respiratory rate. EmRad discerns itself by emphasizing miniaturization, performance, scalability, and its ability to generate large-scale datasets in various environments. This article explains the system's design, focusing on signal processing strategies and motion artifact reduction to ensure precise vital sign extraction. The EmRad system's versatility is showcased through various case studies, highlighting its potential to transform vital sign monitoring in research and clinical contexts.
- 28 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 5, 725-734
Open AccessEmRad: Ubiquitous Vital Sign Sensing Using Compact Continuous-Wave Radars
In biomedical monitoring, non-intrusive and continuous tracking of vital signs is a crucial yet challenging objective. Although accurate, traditional methods, such as electrocardiography (ECG) and photoplethysmography (PPG), necessitate direct contact with the patient, posing limitations for long-term and unobtrusive monitoring. To address this challenge, we introduce the EmRad system, an innovative solution harnessing the capabilities of continuous-wave (CW) radar technology for the contactless detection of vital signs, including heart rate and respiratory rate. EmRad discerns itself by emphasizing miniaturization, performance, scalability, and its ability to generate large-scale datasets in various environments. This article explains the system's design, focusing on signal processing strategies and motion artifact reduction to ensure precise vital sign extraction. The EmRad system's versatility is showcased through various case studies, highlighting its potential to transform vital sign monitoring in research and clinical contexts.
- Open Access
- 6 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 5, 680-699
A Review and Tutorial on Machine Learning-Enabled Radar-Based Biomedical Monitoring
Radio detection and ranging-based (radar) sensing offers unique opportunities for biomedical monitoring and can help overcome the limitations of currently established solutions. Due to its contactless and unobtrusive measurement principle, it can facilitate the longitudinal recording of human physiology and can help to bridge the gap from laboratory to real-world assessments. However, radar sensors typically yield complex and multidimensional data that are hard to interpret without domain expertise. Machine learning (ML) algorithms can be trained to extract meaningful information from radar data for medical experts, enhancing not only diagnostic capabilities but also contributing to advancements in disease prevention and treatment. However, until now, the two aspects of radar-based data acquisition and ML-based data processing have mostly been addressed individually and not as part of a holistic and end-to-end data analysis pipeline. For this reason, we present a tutorial on radar-based ML applications for biomedical monitoring that equally emphasizes both dimensions. We highlight the fundamentals of radar and ML theory, data acquisition and representation and outline categories of clinical relevance. Since the contactless and unobtrusive nature of radar-based sensing also raises novel ethical concerns regarding biomedical monitoring, we additionally present a discussion that carefully addresses the ethical aspects of this novel technology, particularly regarding data privacy, ownership, and potential biases in ML algorithms.
- 6 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 5, 680-699
Open AccessA Review and Tutorial on Machine Learning-Enabled Radar-Based Biomedical Monitoring
Radio detection and ranging-based (radar) sensing offers unique opportunities for biomedical monitoring and can help overcome the limitations of currently established solutions. Due to its contactless and unobtrusive measurement principle, it can facilitate the longitudinal recording of human physiology and can help to bridge the gap from laboratory to real-world assessments. However, radar sensors typically yield complex and multidimensional data that are hard to interpret without domain expertise. Machine learning (ML) algorithms can be trained to extract meaningful information from radar data for medical experts, enhancing not only diagnostic capabilities but also contributing to advancements in disease prevention and treatment. However, until now, the two aspects of radar-based data acquisition and ML-based data processing have mostly been addressed individually and not as part of a holistic and end-to-end data analysis pipeline. For this reason, we present a tutorial on radar-based ML applications for biomedical monitoring that equally emphasizes both dimensions. We highlight the fundamentals of radar and ML theory, data acquisition and representation and outline categories of clinical relevance. Since the contactless and unobtrusive nature of radar-based sensing also raises novel ethical concerns regarding biomedical monitoring, we additionally present a discussion that carefully addresses the ethical aspects of this novel technology, particularly regarding data privacy, ownership, and potential biases in ML algorithms.