Vo Hong Hai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Vo Hong Hai has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Nguyen Tri Toan Phuc
Univ Sci, Fac Phys & Engn Phys, Dept Nucl Phys, Ho Chi Minh City, Vietnam
3 shared publications- Nguyen Tri Toan Phuc
University of Science
3 shared publications - Truong Thi Hong Loan
Department of Nuclear Physics, Faculty of Physics and Engineering Physics, University of Science, Ho Chi Minh City, Vietnam
3 shared publications - Hoang Thi Kieu Trang
Department of Nuclear Physics, Faculty of Physics and Engineering Physics, University of Sciences, Ho Chi Minh City, Vietnam
2 shared publications - Masaharu Nomachi
Osaka Univ, 1-1 Yamadaoka, Suita, Osaka 5650871, Japan
2 shared publications - Phan Le Hoang Sang
Department of Nuclear Physics, Faculty of Physics and Engineering Physics, University of Science-VNUHCM, Ho Chi Minh City, Vietnam
2 shared publications
Latest Publications
- 23 October 2024
- Published by Elsevier in Radiation Measurements
- Vol. 179
Contributions of cosmic-ray components to the HPGe gamma spectrometer background spectrum within the 0°–45° Zenith angle range
- 23 October 2024
- Published by Elsevier in Radiation Measurements
- Vol. 179
Contributions of cosmic-ray components to the HPGe gamma spectrometer background spectrum within the 0°–45° Zenith angle range
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 380-384
Development of FPGA-Based Nuclear Electronics Using NI MyRIO Hardware for Small-Scale Radiation Detector Systems
This study presents advancements in coincidence electronics and a Pulse Height Analyzer (PHA) utilizing commercial FPGA-based (Field-Programmable Gate Array) hardware for radiation scintillation detectors. The hardware, based on a cost-effective NI myRIO device, integrates an FPGA, ARM Cortex-A9 processor, analog input (AI), digital input and output (DIO), and USB/wireless connectivity with a host computer. LabVIEW codes developed on the LabVIEW™ platform are implemented in the NI myRIO hardware for seamless integration and interfacing with a computer. The performance of the FPGA-based coincidence electronics is assessed through an experimental setup measuring the gamma-gamma angular distribution of a 22 Na radioisotope source. Similarly, the FPGA-based PHA is tested with a CsI(Tl) detector, and its energy resolution is compared to a commercial EASY-MCA 2K from AMETEK Inc.
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 380-384
Development of FPGA-Based Nuclear Electronics Using NI MyRIO Hardware for Small-Scale Radiation Detector Systems
This study presents advancements in coincidence electronics and a Pulse Height Analyzer (PHA) utilizing commercial FPGA-based (Field-Programmable Gate Array) hardware for radiation scintillation detectors. The hardware, based on a cost-effective NI myRIO device, integrates an FPGA, ARM Cortex-A9 processor, analog input (AI), digital input and output (DIO), and USB/wireless connectivity with a host computer. LabVIEW codes developed on the LabVIEW™ platform are implemented in the NI myRIO hardware for seamless integration and interfacing with a computer. The performance of the FPGA-based coincidence electronics is assessed through an experimental setup measuring the gamma-gamma angular distribution of a 22 Na radioisotope source. Similarly, the FPGA-based PHA is tested with a CsI(Tl) detector, and its energy resolution is compared to a commercial EASY-MCA 2K from AMETEK Inc.
- 10 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 225-230
Enhancing Neutron/Gamma Discrimination in the Low-Energy Region for EJ-276 Plastic Scintillation Detector Using Machine Learning
Pulse Shape Discrimination (PSD) techniques, particularly the widely employed charge integration ratio method (Q-ratio), have proven effective in discriminating fast neutrons from gamma rays in organic scintillation detectors. However, the effectiveness of Q-ratio diminishes in the low-energy region (below 150 keVee) due to overlapping signal, leading to a suboptimal Figure of Merit (FOM). In this study, we use machine learning (ML) technique, particularly the one-dimensional Convolutional Neural Network (1D-CNN), to enhance the neutron/gamma discrimination and compares the results with the traditional charge integration ratio in the low-energy region. Our investigation focuses on the EJ-276 plastic scintillator, a commercial product of ELJEN technology known for its good separation of gamma and fast neutron signals based on timing characteristics. Experimental data were acquired using 252 Cf and 60 Co radioisotope sources. A comprehensive comparative analysis between the traditional Q-ratio method and ML algorithms is conducted for the low energy region. Our main objective is to evaluate and enhance neutron/gamma discrimination capabilities of plastic scintillators in this low-energy region.
- 10 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (3) , 225-230
Enhancing Neutron/Gamma Discrimination in the Low-Energy Region for EJ-276 Plastic Scintillation Detector Using Machine Learning
Pulse Shape Discrimination (PSD) techniques, particularly the widely employed charge integration ratio method (Q-ratio), have proven effective in discriminating fast neutrons from gamma rays in organic scintillation detectors. However, the effectiveness of Q-ratio diminishes in the low-energy region (below 150 keVee) due to overlapping signal, leading to a suboptimal Figure of Merit (FOM). In this study, we use machine learning (ML) technique, particularly the one-dimensional Convolutional Neural Network (1D-CNN), to enhance the neutron/gamma discrimination and compares the results with the traditional charge integration ratio in the low-energy region. Our investigation focuses on the EJ-276 plastic scintillator, a commercial product of ELJEN technology known for its good separation of gamma and fast neutron signals based on timing characteristics. Experimental data were acquired using 252 Cf and 60 Co radioisotope sources. A comprehensive comparative analysis between the traditional Q-ratio method and ML algorithms is conducted for the low energy region. Our main objective is to evaluate and enhance neutron/gamma discrimination capabilities of plastic scintillators in this low-energy region.
- 25 June 2024
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 211, 111418
Zenith angle dependence on cosmic-ray background in HPGe gamma spectrometers by using GEANT4 simulation
- 25 June 2024
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 211, 111418
Zenith angle dependence on cosmic-ray background in HPGe gamma spectrometers by using GEANT4 simulation
- Open Access
- 1 January 2024
- Published by Viet Nam National University Ho Chi Minh City in Journal of Science and Technology Development
- Vol. 27 (2) , 3482-3488
Development and implementation of a wireless real-time radiation monitoring system for LINAC beam delivery monitoring
Introduction: In this work, we developed a wireless, remote, real-time radiation monitoring system designed to oversee beam delivery in a radiation therapy room equipped with a medical linear accelerator (LINAC). Methods: This system utilizes a Geiger-Müller detector paired with embedded electronic hardware to accurately record radiation count rates in real-time. The data collected by this system are transmitted through LAN/WAN networks to the internet, ensuring instantaneous accessibility. In addition, a web server and mobile application were developed to display, receive, and archive the data from the radiation counter. Results: Our system was deployed in the radiation therapy room of the Oncology Hospital in Ho Chi Minh City, demonstrating a remarkable data reception rate of up to 99.8% over a three-day test period from June 27th to 29th, 2022. The system effectively identified beam-on instances and provided precise measurements of the number and duration of beam-on events. Conclusion: This study demonstrates the feasibility of remote real-time radiation monitoring in medical settings and highlights the potential for enhancing radiation safety and treatment efficacy in external beam radiotherapy.
- 1 January 2024
- Published by Viet Nam National University Ho Chi Minh City in Journal of Science and Technology Development
- Vol. 27 (2) , 3482-3488
Open AccessDevelopment and implementation of a wireless real-time radiation monitoring system for LINAC beam delivery monitoring
Introduction: In this work, we developed a wireless, remote, real-time radiation monitoring system designed to oversee beam delivery in a radiation therapy room equipped with a medical linear accelerator (LINAC). Methods: This system utilizes a Geiger-Müller detector paired with embedded electronic hardware to accurately record radiation count rates in real-time. The data collected by this system are transmitted through LAN/WAN networks to the internet, ensuring instantaneous accessibility. In addition, a web server and mobile application were developed to display, receive, and archive the data from the radiation counter. Results: Our system was deployed in the radiation therapy room of the Oncology Hospital in Ho Chi Minh City, demonstrating a remarkable data reception rate of up to 99.8% over a three-day test period from June 27th to 29th, 2022. The system effectively identified beam-on instances and provided precise measurements of the number and duration of beam-on events. Conclusion: This study demonstrates the feasibility of remote real-time radiation monitoring in medical settings and highlights the potential for enhancing radiation safety and treatment efficacy in external beam radiotherapy.
- Open Access
- 1 January 2023
- Published by Viet Nam National University Ho Chi Minh City in Journal of Science and Technology Development
- Vol. 26 (3) , 2930-2936
Sensitivity of secondary particle emission to hadronic physics models in GATE/Geant4 proton therapy simulations at 100 MeV
Introduction: Proton therapy simulations rely on Monte Carlo techniques, such as the GATE code based on the Geant4 toolkit, to predict dose distribution and secondary particle production. The accuracy of these simulations is heavily influenced by the chosen physics models. Methods: In this study, we analyzed three Geant4 hadronic physics models, BIC, BERT, and INCL++, by calculating the angular and energy distributions of secondary neutrons and gamma particles. We conducted GATE/Geant4 simulations on a water phantom irradiated with a 100 MeV proton beam. Results: Our investigation revealed notable differences in the angular and energy distributions of emitted particles among the three models. Conclusion: This study emphasizes the necessity of carefully selecting a hadronic physics model for GATE/Geant4 simulations in proton therapy.
- 1 January 2023
- Published by Viet Nam National University Ho Chi Minh City in Journal of Science and Technology Development
- Vol. 26 (3) , 2930-2936
Open AccessSensitivity of secondary particle emission to hadronic physics models in GATE/Geant4 proton therapy simulations at 100 MeV
Introduction: Proton therapy simulations rely on Monte Carlo techniques, such as the GATE code based on the Geant4 toolkit, to predict dose distribution and secondary particle production. The accuracy of these simulations is heavily influenced by the chosen physics models. Methods: In this study, we analyzed three Geant4 hadronic physics models, BIC, BERT, and INCL++, by calculating the angular and energy distributions of secondary neutrons and gamma particles. We conducted GATE/Geant4 simulations on a water phantom irradiated with a 100 MeV proton beam. Results: Our investigation revealed notable differences in the angular and energy distributions of emitted particles among the three models. Conclusion: This study emphasizes the necessity of carefully selecting a hadronic physics model for GATE/Geant4 simulations in proton therapy.
- Open Access
- 1 January 2023
- Published by Viet Nam National University Ho Chi Minh City in Journal of Science and Technology Development
- Vol. 26 (2) , 2838-2847
Effects of single-particle overlap function on the 16O(p,2p)15N reaction
Introduction: The proton-induced nucleon knockout reactions have been widely used in recent years to explore the single-particle properties of various nuclei. In this study, we examine the effects of the single-particle overlap function on the cross sections and spectroscopic factors of the 16O(p,2p)15N reactions. Methods: These effects are extensively studied through an analysis of the cross sections of the 16O(p,2p)15N reaction at incident energies of 392 and 505 MeV. The evaluation is carried out within the framework of the distorted-wave impulse approximation (DWIA), utilizing overlap function inputs from different structure calculations and potential prescriptions. Results: The analysis reveals that, for the 16O(p,2p)15N reaction and the chosen incident energies, the ambiguities arising from different selections of the overlap function are small but non-negligible. Conclusion: Given the existence of these theoretical uncertainties, it is important that careful and consistent choices of single-particle overlap functions are made in systematics knockout reactions analyses to ensure the extraction of reliable structure information.
- 1 January 2023
- Published by Viet Nam National University Ho Chi Minh City in Journal of Science and Technology Development
- Vol. 26 (2) , 2838-2847
Open AccessEffects of single-particle overlap function on the 16O(p,2p)15N reaction
Introduction: The proton-induced nucleon knockout reactions have been widely used in recent years to explore the single-particle properties of various nuclei. In this study, we examine the effects of the single-particle overlap function on the cross sections and spectroscopic factors of the 16O(p,2p)15N reactions. Methods: These effects are extensively studied through an analysis of the cross sections of the 16O(p,2p)15N reaction at incident energies of 392 and 505 MeV. The evaluation is carried out within the framework of the distorted-wave impulse approximation (DWIA), utilizing overlap function inputs from different structure calculations and potential prescriptions. Results: The analysis reveals that, for the 16O(p,2p)15N reaction and the chosen incident energies, the ambiguities arising from different selections of the overlap function are small but non-negligible. Conclusion: Given the existence of these theoretical uncertainties, it is important that careful and consistent choices of single-particle overlap functions are made in systematics knockout reactions analyses to ensure the extraction of reliable structure information.
- Open Access
- 1 January 2023
- Published by Viet Nam National University Ho Chi Minh City in Journal of Science and Technology Development
- Vol. 26 (1) , 2645-2651
Development of apparatus for mean-lifetime measurement of cosmic-ray muons using plastic scintillation detectors and FLASH-ADC/FPGA-based readout electronics
Introduction: This paper presents the development and results of an apparatus for measuring the mean lifetime of cosmic-ray muons. Methods: The apparatus uses three plastic scintillation detectors and a readout electronics system based on Flash Analog Digital Converter (Flash-ADC) and Embedded Field Programmable Gate Array (FPGA). The readout system has 8-bit resolution and a 125 Msample/sec sampling rate. The system's trigger and data collection are controlled through a computer interface based on LabVIEWTM. The readout electronics are calibrated with an accuracy of 8 nsec/TDC channel. Results: Over 6000 events were recorded during the measurements performed at ground level using aluminum as the muon stopping material, and the muon decay time spectrum was obtained and fit with a combination of two exponential components and a constant background. The mean lifetimes of negative and positive muons were determined. Conclusion: Our results indicate that the mean lifetimes of negative and positive muons in aluminum are 0.70 ± 0.24 µsec and 2.05 ± 0.16 µsec, respectively.
- 1 January 2023
- Published by Viet Nam National University Ho Chi Minh City in Journal of Science and Technology Development
- Vol. 26 (1) , 2645-2651
Open AccessDevelopment of apparatus for mean-lifetime measurement of cosmic-ray muons using plastic scintillation detectors and FLASH-ADC/FPGA-based readout electronics
Introduction: This paper presents the development and results of an apparatus for measuring the mean lifetime of cosmic-ray muons. Methods: The apparatus uses three plastic scintillation detectors and a readout electronics system based on Flash Analog Digital Converter (Flash-ADC) and Embedded Field Programmable Gate Array (FPGA). The readout system has 8-bit resolution and a 125 Msample/sec sampling rate. The system's trigger and data collection are controlled through a computer interface based on LabVIEWTM. The readout electronics are calibrated with an accuracy of 8 nsec/TDC channel. Results: Over 6000 events were recorded during the measurements performed at ground level using aluminum as the muon stopping material, and the muon decay time spectrum was obtained and fit with a combination of two exponential components and a constant background. The mean lifetimes of negative and positive muons were determined. Conclusion: Our results indicate that the mean lifetimes of negative and positive muons in aluminum are 0.70 ± 0.24 µsec and 2.05 ± 0.16 µsec, respectively.
- Open Access
- 20 January 2020
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 225, 10004
International school for radiation measurements in Asia
Radiation measurement is a key technology for various sciences. The education of radiation science is demanding in Southeast Asian countries. We are collaborating with Universities in Southeast Asia. Hands-on exercise is important. However, it was not so easy to provide enough number of setups. Recent developments change the situation. The granularity of detectors in particle physics and medical apparatus is increasing. It means detector unit becomes smaller and less expensive. We are developing setups for radiation measurement exercises based on those new developments. Those system is portable to carry. In Osaka University, we are organizing schools for radiation measurements inviting Southeast Asian students. In addition, we are organizing schools in Southeast Asia. Compact system helps us to carry.
- 20 January 2020
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 225, 10004
Open AccessInternational school for radiation measurements in Asia
Radiation measurement is a key technology for various sciences. The education of radiation science is demanding in Southeast Asian countries. We are collaborating with Universities in Southeast Asia. Hands-on exercise is important. However, it was not so easy to provide enough number of setups. Recent developments change the situation. The granularity of detectors in particle physics and medical apparatus is increasing. It means detector unit becomes smaller and less expensive. We are developing setups for radiation measurement exercises based on those new developments. Those system is portable to carry. In Osaka University, we are organizing schools for radiation measurements inviting Southeast Asian students. In addition, we are organizing schools in Southeast Asia. Compact system helps us to carry.