Zhi Cai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhi Cai has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Dawei Zhang
State Grid Sichuan Electric Power Company, Chengdu 610041, China
1 shared publication - Haiyang Liu
State Grid Sichuan Electric Power Company, Baoding 610041, China
1 shared publication - Lili Wen
State Grid Sichuan Electric Power Company, Baoding 610041, China
1 shared publication - Renhai Feng
Xinjiang Normal University
1 shared publication - Wajid Khan
School of Electrical and Information Engineering, Tianjin University, Tianjin, China
1 shared publication - Yanfeng Wang
State Grid Sichuan Electric Power Company, Baoding 610041, China
1 shared publication
Latest Publications
- Open Access
- 30 June 2024
- Published by MDPI AG in Electronics
- Vol. 13 (13) , 2576
Digital Twin Modeling for Hydropower System Based on Radio Frequency Identification Data Collection
The safe and steady operation of hydropower generation systems is crucial for electricity output in the grid. However, hydropower stations have complicated interior structures, making defect detection difficult without disassembly inspections. The application of digital modeling to hydropower stations will effectively promote the intelligent transformation of hydropower stations as well as reduce the maintenance costs of the system. This study provides a model of the power generating and transmission system for hydropower plants, with an emphasis on primary equipment and measured data. The model utilizes PSCAD to digitalize state response in hydropower plants with various short-circuit faults. The fault information is identified and learned using the Adaptive Time–Frequency Memory (AD-TFM) deep learning model. It is demonstrated that our proposed method can effectively obtain the fault information through radio frequency identification (RFID). The accuracy of the traditional method is 0.90, while the results for AD-TFM show a fault classification accuracy of 0.92, which is more than enough to identify multiple fault types compared to the existing methods.
- 30 June 2024
- Published by MDPI AG in Electronics
- Vol. 13 (13) , 2576
Open AccessDigital Twin Modeling for Hydropower System Based on Radio Frequency Identification Data Collection
The safe and steady operation of hydropower generation systems is crucial for electricity output in the grid. However, hydropower stations have complicated interior structures, making defect detection difficult without disassembly inspections. The application of digital modeling to hydropower stations will effectively promote the intelligent transformation of hydropower stations as well as reduce the maintenance costs of the system. This study provides a model of the power generating and transmission system for hydropower plants, with an emphasis on primary equipment and measured data. The model utilizes PSCAD to digitalize state response in hydropower plants with various short-circuit faults. The fault information is identified and learned using the Adaptive Time–Frequency Memory (AD-TFM) deep learning model. It is demonstrated that our proposed method can effectively obtain the fault information through radio frequency identification (RFID). The accuracy of the traditional method is 0.90, while the results for AD-TFM show a fault classification accuracy of 0.92, which is more than enough to identify multiple fault types compared to the existing methods.