Jacob A. Sandler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jacob A. Sandler has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Guy M. Genin
NSF Science and Technology Center for Engineering Mechanobiology, Washington University in St. Louis, MO, USA
2 shared publications Aliza Mujahid
NSF Science and Technology Center for Engineering Mechanobiology, USA; Department of Mechanical Engineering, New Jersey Institute of Technology, USA
1 shared publicationChelsea F Garcia
Department of Mechanical Engineering, New Jersey Institute of Technology, USA
1 shared publicationDanial Cheraghali
NSF Science and Technology Center for Engineering Mechanobiology, USA; Department of Mechanical Engineering, New Jersey Institute of Technology, USA
1 shared publication- David Ju
NSF Science and Technology Center for Engineering Mechanobiology, Saint Louis, USA
1 shared publication - Delaram Shakiba
NSF Science and Technology Center for Engineering Mechanobiology, Saint Louis, USA
1 shared publication
Latest Publications
- 22 November 2024
- Published by Elsevier in Acta Biomaterialia
- Vol. 191, 325-335
Expansion limits of meshed split-thickness skin grafts
- 22 November 2024
- Published by Elsevier in Acta Biomaterialia
- Vol. 191, 325-335
Expansion limits of meshed split-thickness skin grafts
- Open Access
- 28 June 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (26) , eadl5270
Python tooth–inspired fixation device for enhanced rotator cuff repair
Rotator cuff repair surgeries fail frequently, with 20 to 94% of the 600,000 repairs performed annually in the United States resulting in retearing of the rotator cuff. The most common cause of failure is sutures tearing through tendons at grasping points. To address this issue, we drew inspiration from the specialized teeth of snakes of the Pythonoidea superfamily, which grasp soft tissues without tearing. To apply this nondamaging gripping approach to the surgical repair of tendon, we developed and optimized a python tooth–inspired device as an adjunct to current rotator cuff suture repair and found that it nearly doubled repair strength. Integrated simulations, 3D printing, and ex vivo experiments revealed a relationship between tooth shape and grasping mechanics, enabling optimization of the clinically relevant device that substantially enhances rotator cuff repair by distributing stresses over the attachment footprint. This approach suggests an alternative to traditional suturing paradigms and may reduce the risk of tendon retearing after rotator cuff repair.
- 28 June 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (26) , eadl5270
Open AccessPython tooth–inspired fixation device for enhanced rotator cuff repair
Rotator cuff repair surgeries fail frequently, with 20 to 94% of the 600,000 repairs performed annually in the United States resulting in retearing of the rotator cuff. The most common cause of failure is sutures tearing through tendons at grasping points. To address this issue, we drew inspiration from the specialized teeth of snakes of the Pythonoidea superfamily, which grasp soft tissues without tearing. To apply this nondamaging gripping approach to the surgical repair of tendon, we developed and optimized a python tooth–inspired device as an adjunct to current rotator cuff suture repair and found that it nearly doubled repair strength. Integrated simulations, 3D printing, and ex vivo experiments revealed a relationship between tooth shape and grasping mechanics, enabling optimization of the clinically relevant device that substantially enhances rotator cuff repair by distributing stresses over the attachment footprint. This approach suggests an alternative to traditional suturing paradigms and may reduce the risk of tendon retearing after rotator cuff repair.