Yulia V. Sokolnikova
Research Subjects
Research Interests
Yulia V. Sokolnikova has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Boris A. Baenguev
Институт геохимии им. А.П. Виноградова СО РАН
2 shared publications - Elena Vladimirovna Chuparina
Vinogradov Institute of Geochemistry SB RAS
2 shared publications - Galina A. Belogolova
Институт геохимии им. А.П. Виноградова СО РАН
2 shared publications - Alena Andreevna Amosova
Vinogradov Institute of Geochemistry Siberian Branch of the Russian Academy of Sciences Irkutsk Russian Federation
1 shared publication - Alexander L. Finkelshtein
Vinogradov Institute of Geochemistry, SB RAS Irkutsk Russia
1 shared publication - Mikhail V. Pastukhov
Vinogradov Institute of Geochemistry SB RAS, Irkutsk, Russia
1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by Ural Federal University in Аналитика и контроль
- Vol. 29 (1) , 83-95
Determination of divalent iron content in reference materials of rocks and soils by X-ray fluorescence analysis
The potential of the X-ray fluorescence method as a tool for assessing the ratio of valence forms of iron in reference materials of soils, igneous and sedimentary rocks for the purpose of their characterization is described. The method is based on the dependence of the ratio of intensities of FeKβ5 and FeKβ1,3 emission lines on iron valent state. The study was carried out using a wavelength-dispersive X-ray fluorescence spectrometer. Forty-four reference materials of igneous and sedimentary rocks produced in Russia and Mongolia were used as calibration set. The content of total and divalent iron (present as FeO oxide) in these samples was certified, with the fraction of divalent iron from 2 to 92 % in the total iron content. Fourteen reference materials with unknown FeO content were analyzed by proposed X-ray fluorescence technique. The obtained data showed satisfactory agreement with the results of analysis by the reference dichromate titration technique (NSAM No. 50-X). In addition, 6 reference materials with approximate values of FeO content were analyzed. The results obtained by the X-ray fluorescence technique showed satisfactory agreement with the estimate data. For 20 reference materials with FeO content from 0.23 to 8.8 %, the standard deviation in determination by the X-ray fluorescence method was 0.30 %. The information on FeO content in the reference samples of soils, igneous and sedimentary rocks obtained for the first time can be used in the analytical practice and be useful for geologists.
- 1 January 2025
- Published by Ural Federal University in Аналитика и контроль
- Vol. 29 (1) , 83-95
Open AccessDetermination of divalent iron content in reference materials of rocks and soils by X-ray fluorescence analysis
The potential of the X-ray fluorescence method as a tool for assessing the ratio of valence forms of iron in reference materials of soils, igneous and sedimentary rocks for the purpose of their characterization is described. The method is based on the dependence of the ratio of intensities of FeKβ5 and FeKβ1,3 emission lines on iron valent state. The study was carried out using a wavelength-dispersive X-ray fluorescence spectrometer. Forty-four reference materials of igneous and sedimentary rocks produced in Russia and Mongolia were used as calibration set. The content of total and divalent iron (present as FeO oxide) in these samples was certified, with the fraction of divalent iron from 2 to 92 % in the total iron content. Fourteen reference materials with unknown FeO content were analyzed by proposed X-ray fluorescence technique. The obtained data showed satisfactory agreement with the results of analysis by the reference dichromate titration technique (NSAM No. 50-X). In addition, 6 reference materials with approximate values of FeO content were analyzed. The results obtained by the X-ray fluorescence technique showed satisfactory agreement with the estimate data. For 20 reference materials with FeO content from 0.23 to 8.8 %, the standard deviation in determination by the X-ray fluorescence method was 0.30 %. The information on FeO content in the reference samples of soils, igneous and sedimentary rocks obtained for the first time can be used in the analytical practice and be useful for geologists.
- 23 October 2024
- Published by Taylor & Francis in Chemistry and Ecology
- Vol. 41 (2) , 173-193
The mechanism of arsenic behaviour in the soil-plant system and its interaction with biogenic macroelements of plants under conditions of toxic stress
- 23 October 2024
- Published by Taylor & Francis in Chemistry and Ecology
- Vol. 41 (2) , 173-193
The mechanism of arsenic behaviour in the soil-plant system and its interaction with biogenic macroelements of plants under conditions of toxic stress
- 18 June 2024
- Published by Wiley in X-Ray Spectrometry
- Vol. 54 (2) , 108-117
Application of some calibration strategies in comparison to determine Cr, Ni, Cu, Zn, As, and Pb in contaminated plants by wavelength dispersive x‐ray fluorescence
The study of nonstandard samples wherein their element compositions differ from those of routine samples motivates analysts to look for new methodological approaches. To determine the high concentrations of Cr, Ni, Cu, Zn, As, and Pb in polluted plants, the authors applied wavelength dispersive x‐ray fluorescence (WDXRF), using three calibration strategies in comparison. The following sets of calibration samples were tested: available plant and biological CRMs; synthetic samples; and “house reference materials” (HRMs). The synthetic samples were prepared, adding small portions of the loose sediment CRMs to a plant CRM. The polluted plant samples, analyzed by atomic absorption spectrometry and inductively coupled plasma mass spectrometry, were used as HRMs to construct the calibration curves and validate XRF results. It was ascertained that all three calibration strategies can be used to quantify above elements in contaminated plants, providing different precision of WDXRF results. The calibration procedure with HRMs has provided the least errors in the element determinations. Calibration with synthetic samples causes larger errors due to some differences in chemical compositions between calibration and analyzed samples as well as due to probable errors in the synthetic sample preparation. The calibration with plant and biological samples is of limited applicability in XRF of contaminated plants by reason of narrow content ranges of some elements.
- 18 June 2024
- Published by Wiley in X-Ray Spectrometry
- Vol. 54 (2) , 108-117
Application of some calibration strategies in comparison to determine Cr, Ni, Cu, Zn, As, and Pb in contaminated plants by wavelength dispersive x‐ray fluorescence
The study of nonstandard samples wherein their element compositions differ from those of routine samples motivates analysts to look for new methodological approaches. To determine the high concentrations of Cr, Ni, Cu, Zn, As, and Pb in polluted plants, the authors applied wavelength dispersive x‐ray fluorescence (WDXRF), using three calibration strategies in comparison. The following sets of calibration samples were tested: available plant and biological CRMs; synthetic samples; and “house reference materials” (HRMs). The synthetic samples were prepared, adding small portions of the loose sediment CRMs to a plant CRM. The polluted plant samples, analyzed by atomic absorption spectrometry and inductively coupled plasma mass spectrometry, were used as HRMs to construct the calibration curves and validate XRF results. It was ascertained that all three calibration strategies can be used to quantify above elements in contaminated plants, providing different precision of WDXRF results. The calibration procedure with HRMs has provided the least errors in the element determinations. Calibration with synthetic samples causes larger errors due to some differences in chemical compositions between calibration and analyzed samples as well as due to probable errors in the synthetic sample preparation. The calibration with plant and biological samples is of limited applicability in XRF of contaminated plants by reason of narrow content ranges of some elements.