NENico Egger

Nico Egger

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nico Egger has a total of 25 co-authors. Here are the top co-authors by number of shared publications:

  • Armin Michael Nagel

    Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-University Erlangen-Nürnberg, Germany (A.M.N.).

    5 shared publications
  • Andreas Bitz

    Electrical Engineering and Information Technology University of Applied Sciences – FH Aachen Aachen Germany

    4 shared publications
  • Laurent Ruck

    Institute of Radiology, University Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU) Erlangen Germany

    4 shared publications
  • Michael Uder

    Institute of Radiology, University Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU) Erlangen Germany

    4 shared publications
  • Sophia Nagelstraßer

    Institute of Radiology, University Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU) Erlangen Germany

    4 shared publications
  • Judith Schirmer

    Institute of Radiology, University Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU) Erlangen Germany

    3 shared publications

Latest Publications

  • Open Access

    Improved Myocardial Sodium Quantification at 7 T Using Interleaved 23 Na / 1 H pTx MRI With Motion and Anatomy‐Based B 1 Correction

    by Laurent Ruck, Nico Egger, Benedikt Zobler, Judith Schirmer, Sophia Nagelstraßer, Andreas Bitz, Tanja Platt, Simon Konstandin, Christoph Kopp, Michael Uder, et al.

    Purpose: To improve accuracy and repeatability of myocardial 23 Na quantification in cardiac MRI at 7 T by combining retrospective respiratory and cardiac motion correction with a novel anatomy‐based B 1 bias field correction. Methods: In this study, a dual‐nuclear interleaved 23 Na/ 1 H MRI sequence at 7 T was applied. Here, 1 H MR data enabled automated segmentation of myocardium and blood pool via nnUNet and facilitated respiratory and cardiac motion correction for both contrasts using 1 H navigators. For 23 Na MRI, a novel anatomy‐based B 1 bias field correction was developed, estimating the transmit and receive (B 1 ) field bias from 1 H‐derived segmentations and synthetic 23 Na images. All correction methods were validated through realistic simulations and in vivo studies. Repeatability was assessed in 10 healthy subjects, and the proposed B 1 correction was compared to phantom‐based methods. Results: Respiratory and cardiac motion correction reduced quantification errors and improved SNR compared to conventional gating. The anatomy‐based B 1 correction effectively mitigated errors caused by B 1 inhomogeneities and outperformed phantom‐based methods in terms of repeatability. The measured apparent tissue sodium concentration of the myocardium after all corrections (49.5 4.7 mM) was consistent with literature values. Combined motion and B 1 corrections improved repeatability, reducing the coefficient of repeatability from 4.9 mM (11.2%) without corrections to 2.0 mM (4.0%) after corrections. Conclusion: The combination of retrospective motion correction and anatomy‐based B 1 bias field correction enables repeatable myocardial sodium quantification at 7 T. The interleaved acquisition facilitates robust segmentation and efficient use of 1 H MRI for motion and B 1 correction, providing a scalable framework for future clinical research studies.


  • Open Access

    Fat/Water Separation at 7 T Using a 3D Radial Sequence With Quasi‐Continuous Echo Times

    by Matthias Rohe, Katharina Tkotz, Armin M. Nagel, Stefan Sommer, Max Brockmüller, Florian Knoll, Michael Uder, Nico Egger, Frederik B. Laun, Tobias Wilferth

    Purpose: To achieve a reliable fat/water separation (FWS) at 7 T using a new 3D radial sequence and reconstruction workflow with quasi‐continuous TE sampling. Methods: A 3D radial density‐adapted sequence with quasi‐continuous TE sampling was developed for a 7 T whole‐body MRI system. The reconstruction workflow included an off‐resonance correction to reduce chemical shift artifacts. Fat and water signals were separated using a graph cut algorithm, yielding proton density fat fraction maps. The sequence and reconstruction pipeline were tested and validated using phantom measurements and in vivo acquisitions of the lower leg of healthy volunteers. Results: The proposed sequence and reconstruction pipeline enabled sampling of the fat/water oscillation curve over a range from a minimal mean TE of 0.27 ms to a maximum mean TE of 10.13 ms, with an effective TE increment of 85 μs. The off‐resonant correction significantly reduced chemical shift artifacts in the fat signal. The data points of the fat/water oscillation showed good agreement with a multi‐peak fit function. The quantification of phantom fat percentages was verified with a mean absolute error of 1.5%. The proposed pipeline resulted in consistent interpretation of fat and water signals without any swaps, neither in phantom nor in in vivo measurements. Conclusion: This study successfully demonstrated the application of a 3D radial sequence with quasi‐continuous TEs for FWS at 7 T. Due to the high sampling rate (effective TE increment below 100 μs), the presented FWS workflow demonstrated high robustness against fat/water swaps, which are typical at ultra‐high field strengths.


  • Open Access

    Evaluation of an interleaved acquisition scheme for improved robustness of channel‐wise relative B 1 + mapping at 7 T

    by Nico Egger, Laurent Ruck, Sophia Nagelstraßer, Judith Schirmer, Saskia Wildenberg, Andreas Bitz, Jürgen Herrler, Sebastian Schmitter, Michael Uder, Armin Michael Nagel

    Purpose: The purpose was to evaluate, whether an interleaved acquisition scheme for a fast relative mapping method at 7 T reduces the likelihood of errors from exceeding the linear flip angle (FA) regime compared to a conventional sequential acquisition. Methods: Simulations of a channel‐wise relative mapping sequence were performed for sequential and interleaved acquisition schemes at different reference voltages (≙ different FAs). The simulations were performed for a phantom, the heart and the prostate and were based on 7 T ground‐truth (GT) data acquired with an actual FA imaging sequence (phantom) or obtained from electromagnetic field simulations (heart/prostate). Acquisition schemes were evaluated based on their signal linearity by calculating a normalized mean FA error between simulated signal intensities and GT data. Additionally, validation measurements of relative maps with the sequential and interleaved acquisition schemes were acquired for the phantom. Results: Validation measurements showed a good agreement with the simulation results for both acquisition schemes and displayed stronger deviations to the GT data for the sequential scheme. The quantitative evaluation yielded higher FA errors for the sequential acquisition scheme for all three regions and all simulated reference voltages. At the same level of error, mean signals were higher for the interleaved acquisition scheme in all cases. Differences between interleaved and sequential acquisition schemes were most pronounced in the steady‐state. Conclusion: An interleaved acquisition of channel‐wise relative maps extends the range of the linear FA regime, reducing the likelihood of errors and increasing the robustness of the approach.


  • Open Access

    Interleaved 23 Na / 1 H MRI of the human heart at 7 T using a combined 23 Na / 1 H coil setup and 1 H parallel transmission

    by Laurent Ruck, Nico Egger, Tobias Wilferth, Judith Schirmer, Lena Vanessa Gast, Sophia Nagelstraßer, Saskia Wildenberg, Andreas Bitz, Titus Lanz, Tanja Platt, et al.

    Purpose: To evaluate the feasibility of interleaved 23 Na/ 1 H cardiac MRI at 7 T using 1 H parallel transmission (pTx) pulses. Methods: A combined setup consisting of a 23 Na volume coil and two 1 H transceiver arrays was employed and the transmit and receive characteristics were compared in vitro with those of the uncombined radiofrequency coils. Furthermore, the implemented interleaved 23 Na/ 1 H pTx sequence was validated in phantom measurements and applied to four healthy subjects. For the latter, three customized 1 H excitation pulses (universal and individual phase shims (UPS/IPS) and individual 4kT pulses (4kT)) were employed in the interleaved 23 Na/ 1 H pTx sequence and compared with the vendor‐provided default cardiac phase shim (DPS). Results: Combining both coils resulted in a reduction of the mean 23 Na transmit field (B 1 + ) efficiency and 23 Na signal‐to‐noise ratio by 18.9% and 15.4% for the combined setup, whereas the 1 H B 1 + efficiency was less influenced (−4.7%). Compared with single‐nuclear acquisitions, interleaved dual‐nuclear 23 Na/ 1 H MRI showed negligible influence on 23 Na and 1 H image quality. For all three customized 1 H pTx pulses the B 1 + homogeneity was improved (coefficients of variation: CV UPS = 0.30, CV IPS = 0.23, CV 4kT = 0.15) and no 1 H signal dropouts occurred compared with the vendor‐provided default phase shim (CV DPS = 0.37). Conclusion: The incorporation of customized 1 H pTx pulses in an interleaved 23 Na/ 1 H sequence scheme was successfully demonstrated at 7 T and improvements of the 1 H B 1 + homogeneity within the heart were shown. Combining interleaved 23 Na/ 1 H MRI with 1 H pTx is an important tool to enable robust quantification of myocardial tissue sodium concentrations at 7 T within clinically acceptable acquisition times.


  • Open Access

    Accelerated B1+$ {\mathrm{B}}_1^{+} $ mapping and robust parallel transmit pulse design for heart and prostate imaging at 7 T

    by Nico Egger, Sophia Nagelstraßer, Saskia Wildenberg, Andreas Bitz, Laurent Ruck, Jürgen Herrler, Christian Rainer Meixner, Ralph Kimmlingen, Titus Lanz, Sebastian Schmitter, et al.

    Purpose: To investigate the impact of reduced k‐space sampling on mapping and the resulting impact on phase shimming and dynamic/universal parallel transmit (pTx) RF pulse design.Methods: Channel‐wise 3D maps were measured at 7 T in 35 and 23 healthy subjects for the heart and prostate region, respectively. With these maps, universal phase shims optimizing homogeneity and efficiency were designed for heart and prostate imaging. In addition, universal 4kT‐point pulses were designed for the heart. Subsequently, individual phase shims and individual 4kT‐pulses were designed based on maps with different acceleration factors and tested on the original maps. The performance of the pulses was compared by evaluating their coefficients of variation (CoV), efficiencies and specific energy doses (SED). Furthermore, validation measurements were carried out for one heart and one prostate subject.Results: For both organs, the universal phase shims showed significantly higher efficiencies and lower CoVs compared to the vendor provided default shim, but could still be improved with individual phase shims based on accelerated maps (acquisition time = 30 s). In the heart, the universal 4kT‐pulse achieved significantly lower CoVs than tailored phase shims. Tailored 4kT‐pulses based on accelerated maps resulted in even further reduced CoVs or a 2.5‐fold reduction in SED at the same CoVs as the universal 4kT‐pulse.Conclusion: Accelerated maps can be used for the design of tailored pTx pulses for prostate and cardiac imaging at 7 T, which further improve homogeneity, efficiency, or SED compared to universal pulses.